A three-year clinical evaluation of two-bottle versus one-bottle dentin adhesives

被引:47
|
作者
Aw, TC
Lepe, X
Johnson, GH
Mancl, LA
机构
[1] Univ Washington, Sch Dent, Dept Restorat Dent, Div Operat Dent, Seattle, WA 98195 USA
[2] Univ Washington, Sch Dent, Dept Restorat Dent, Div Prosthodont, Seattle, WA 98195 USA
[3] Univ Washington, Sch Dent, Dept Restorat Dent, Div Dent Mat Sci, Seattle, WA 98195 USA
[4] Univ Washington, Sch Dent, Dept Dent Publ Hlth Sci, Seattle, WA 98195 USA
来源
关键词
noncarious cervical acceptably; class V restorations; bonding agents; solvents; adhesive retention;
D O I
10.14219/jada.archive.2005.0171
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The authors conducted an in vivo investigation to compare the clinical performance of two commercial one-bottle adhesives and a two-bottle adhesive for restoration of noncarious cervical lessons (NCCLs). Method. The patient pool consisted of 57 patients and 171 teeth (three teeth per patient), with one NCCL per tooth. Each patient received three resin-based composite restorations, each with a different adhesive one tooth with a two-bottle, water-based adhesive as the control; another tooth with a one-bottle, ethanol-based adhesive; and a third tooth, with a one-bottle, solvent-free adhesive. The authors assessed restorations in terms of retention, marginal integrity margin discoloration and air sensitivity at baseline, six months, one year, two years and three years after initial placement. Results: The retention rates at 36 months were 88 percent for the first adhesive, 81 percent for the second adhesive and 90 percent for the third adhesive. No statistically significant differences in retention rates could be shown, with 86 percent of restorations retained overall. Measures of marginal integrity, marginal discoloration and sensitivity also had no statistically significant differences (P > .05). Conclusions: All three adhesives performed with acceptable outcomes after a 36-month period, with small differences between one- and two-bottle systems and between the various solvents. Retention rate was moderately high and air sensitivity was markedly reduced; however, superficial marginal discoloration and marginal degradation was notable. Certain lesion, tooth and patient characteristics may predispose restorations to retention failure.
引用
收藏
页码:311 / 322
页数:12
相关论文
共 50 条
  • [1] Clinical evaluation of two one-bottle dentin adhesives at three years
    Swift, EJ
    Perdigao, J
    Wilder, AD
    Heymann, HO
    Sturdevant, JR
    Bayne, SC
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2001, 132 (08): : 1117 - 1123
  • [2] Clinical study of one-bottle versus two-bottle dentin bonding systems.
    Thordrup, M
    Hörsted-Bindslev, P
    [J]. JOURNAL OF DENTAL RESEARCH, 2001, 80 (04) : 1272 - 1272
  • [3] Microtensile bond strengths of one-bottle dentin adhesives
    Cardoso, PEC
    Carrilho, MRO
    Francci, CE
    Perdigao, J
    [J]. AMERICAN JOURNAL OF DENTISTRY, 2001, 14 (01): : 22 - 24
  • [4] Microtensile bond strength and micromorphology of two one-bottle dentin adhesives.
    Xie, B
    Dickens, SH
    Giuseppetti, AA
    [J]. JOURNAL OF DENTAL RESEARCH, 2000, 79 : 374 - 374
  • [5] An eight-year clinical evaluation of filled and unfilled one-bottle dental adhesives
    Ritter, Andre V.
    Swift, Edward J., Jr.
    Heymann, Harald O.
    Sturdevant, John R.
    Wilder, Aldridge D., Jr.
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2009, 140 (01): : 28 - 37
  • [6] In vitro durability of one-bottle resin adhesives bonded to dentin
    Hashimoto, Masanori
    Fujita, Shinichi
    Kaga, Masayuki
    Yawaka, Yasutaka
    [J]. DENTAL MATERIALS JOURNAL, 2007, 26 (05) : 677 - 686
  • [7] Shear bond strength to enamel & dentin using three one-bottle filled adhesives
    Munoz, CA
    Dunn, JR
    Jessop, N
    Sy-Munoz, J
    [J]. JOURNAL OF DENTAL RESEARCH, 2000, 79 : 356 - 356
  • [8] Bonding efficiency of one-bottle adhesives to contaminated dentin surfaces.
    Abdallah, AI
    Davidson, CL
    [J]. JOURNAL OF DENTAL RESEARCH, 1998, 77 : 681 - 681
  • [9] Dentin bond strength of packable composites using one-bottle adhesives
    Jang, KT
    Mejía, FA
    García-Godoy, F
    [J]. AMERICAN JOURNAL OF DENTISTRY, 2000, 13 (06): : 308 - 310
  • [10] Evaporation of solvent in one-bottle adhesives
    Abate, PF
    Rodriguez, VI
    Macchi, RL
    [J]. JOURNAL OF DENTISTRY, 2000, 28 (06) : 437 - 440