Changes in pupillometry associated with dissipated energy during phacoemulsification

被引:2
|
作者
Coco, Giulia [1 ,2 ]
Cremonesi, Pierluca [1 ,3 ]
Menassa, Nardine [1 ]
Pagano, Luca [1 ]
Gadhvi, Kunal A. [1 ]
Semeraro, Francesco [3 ]
Kaye, Stephen B. [1 ,4 ]
Romano, Vito [1 ,4 ]
机构
[1] Royal Liverpool Univ Hosp, St Pauls Eye Unit, Liverpool, Merseyside, England
[2] Univ Roma Tor Vergata, Dept Clin Sci & Translat Med, Rome, Italy
[3] Univ Brescia, Dept Med & Surg Specialties Radiol Specialties &, Brescia, Italy
[4] Univ Liverpool, Inst Life Course & Med Sci, Dept Eye & Vis Sci, Liverpool, Merseyside, England
关键词
Phacoemulsification; ultrasound; CDE; pupil; pupil diameter; NIGHT-VISION DISTURBANCES; PUPIL SIZE; LENS IMPLANTATION; CATARACT-SURGERY; IMAGE QUALITY; ASPIRATION; PRESSURE; LASIK;
D O I
10.1177/1120672120984377
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the effect of ultrasound level during phacoemulsification on pupil dynamics. Methods: Comparative retrospective study on patients who underwent routine cataract surgery at the Royal Liverpool University Hospital. Clinical parameters, anterior chamber measurements, axial length, surgeon grade, time of surgery, level of ultrasound used (cumulative dissipated energy, CDE), intra- and post-operative complications were collected. Pupil diameters were collected before and 4 +/- 1 weeks after surgery in static scotopic, mesopic, photopic pupil conditions. Also, pupil dynamic measurements after luminous stimulus were recorded. Changes in static pupil diameters, relative dilation at 3.5 s after luminous stimulus, and time to reach 75% and 95% of maximum dilation were measured. Results: Forty-eight eyes of 24 patients (13 males) were included with a mean age of 73.1 +/- 14.6 years. Mean CDE value was 18.11 +/- 10.56. Mean scotopic pupil diameters decreased by 0.24 +/- 0.48 mm (p = 0.021) in the operated eye. Significant correlation was found between reduction in scotopic pupil diameter and CDE (p = 0.05). A generalized linear model confirmed that the level of CDE was significantly associated with reduction in scotopic pupil diameter (p = 0.026). Patients who underwent surgeries with lower CDE (0 < CDE <= 10 and 10 < CDE <= 20) did not experience significant changes in scotopic pupil diameter after surgery (p = 0.28 and p = 0.79, respectively) as opposed to those with higher CDE (CDE > 20; p = 0.03). Conclusion: Phacoemulsification cataract surgery and the cumulative dissipated energy may be associated with changes in pupil behaviour.
引用
收藏
页码:2962 / 2968
页数:7
相关论文
共 50 条
  • [1] Cumulative dissipated energy during phacoemulsification: a comparison between surgeons with different training experience
    Montoya, Manuel Antonio Sedano
    Munoz, Erika Fernandez
    Ramos-Betancourt, Nallely
    Ranz, Gabriela Ordonez
    Andrade, Alejandro Abraham Medina
    Salinas, Roberto Gonzalez
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [2] The Effect of Cumulative Dissipated Energy on Changes in Intraocular Pressure After Uncomplicated Cataract Surgery by Phacoemulsification
    Lee, Roland Y.
    Chen, Rebecca I.
    Kasuga, Toshimitsu
    Cui, Qi N.
    Porco, Travis C.
    Lin, Shan C.
    [J]. JOURNAL OF GLAUCOMA, 2016, 25 (07) : 565 - 570
  • [3] Comparison of cumulative dissipated energy between the Infiniti and Centurion phacoemulsification systems
    Chen, Ming
    Anderson, Erik
    Hill, Geoffrey
    Chen, John J.
    Patrianakos, Thomas
    [J]. CLINICAL OPHTHALMOLOGY, 2015, 9 : 1367 - 1372
  • [4] Energy dissipated during spherical indentation
    Jürgen Malzbender
    [J]. Journal of Materials Research, 2004, 19 : 1605 - 1607
  • [5] Energy dissipated during spherical indentation
    Malzbender, J
    [J]. JOURNAL OF MATERIALS RESEARCH, 2004, 19 (06) : 1605 - 1607
  • [6] DISSIPATED ENERGY DURING CYCLIC DEFORMATION
    WIELKE, B
    BIRKHAN, F
    WEISS, B
    [J]. PHYSICA STATUS SOLIDI A-APPLIED RESEARCH, 1973, 17 (01): : 149 - 154
  • [7] Comparison of cumulative dissipated energy utilized in phaco chop versus divide and conquer during phacoemulsification as performed by a resident surgeon
    Keck, Katie M.
    Patterson, Michael
    Markowitz, Bethany
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [8] Determination of the energy dissipated during peel testing
    Breslauer, E
    Troczynski, T
    [J]. MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2001, 302 (01): : 168 - 180
  • [9] VISCOUS ENERGY DISSIPATED DURING THE ATOMIZATION OF A LIQUID
    MONK, GW
    [J]. JOURNAL OF APPLIED PHYSICS, 1952, 23 (02) : 288 - 288
  • [10] Dissipated energy during protective mechanical ventilation
    M Gotti
    M Cressoni
    D Chiumello
    C Chiurazzi
    I Algieri
    M Brioni
    M Amini
    D Massari
    A Cammaroto
    MT Guanziroli
    C Montaruli
    K Nikolla
    L Gattinoni
    [J]. Intensive Care Medicine Experimental, 3 (Suppl 1)