A generalized algorithm for the automatic diagnosis of sleep apnea from per-sample encoding of airflow and oximetry

被引:1
|
作者
Uddin, M. B. [1 ,2 ,3 ]
Chow, C. M. [4 ,5 ]
Ling, S. H. [1 ,2 ]
Su, S. W. [1 ,2 ]
机构
[1] Univ Technol Sydney, Sch Biomed Engn, Fac Engn & Informat Technol, Sydney, NSW, Australia
[2] Univ Technol Sydney, Ctr Hlth Technol, Sydney, NSW, Australia
[3] Khulna Univ Engn & Technol, Dept Biomed Engn, Khulna, Bangladesh
[4] Univ Sydney, Sleep Res Grp, Charles Perkins Ctr, Sydney, NSW, Australia
[5] Univ Sydney, Sydney Sch Hlth Sci, Fac Med & Hlth, Sydney, NSW, Australia
关键词
peak excursion; per-sample encoding; time lag adjustment; computed total sleep time; 4 class accuracy; PORTABLE MONITOR; VALIDATION; EVENTS; POPULATION; HEALTH; DEVICE; RULES; TOOL; OSA;
D O I
10.1088/1361-6579/ac6b11
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objective. Sleep apnea is a common sleep breathing disorder that can significantly decrease sleep quality and have major health consequences. It is diagnosed based on the apnea hypopnea index (AHI). This study explored a novel, generalized algorithm for the automatic diagnosis of sleep apnea employing airflow (AF) and oximetry (SpO(2)) signals. Approach. Of the 988 polysomnography records, 45 were randomly selected for developing the automatic algorithm and the remainder 943 for validating purposes. The algorithm detects apnea events by a per-sample encoding process applied to the peak excursion of AF signal. Hypopnea events were detected from the per-sample encoding of AF and SpO(2) with an adjustment to time lag in SpO(2). Total recording time was automatically processed and optimized for computation of total sleep time (TST). Total number of detected events and computed TST were used to estimate AHI. The estimated AHI was validated against the scored data from the Sleep Heart Health Study. Main results. Intraclass correlation coefficient of 0.94 was obtained between estimated and scored AHIs. The diagnostic accuracies were 93.5%, 92.4%, and 96.6% for AHI cut-off values of >= 5, >= 15, and >= 30 respectively. The overall accuracy for the combined severity categories (normal, mild, moderate, and severe) and kappa were 83.4% and 0.77 respectively. Significance. This new automatic technique was found to be superior to the other existing methods and can be applied to any portable sleep devices especially for home sleep apnea tests.
引用
收藏
页数:11
相关论文
共 14 条
  • [1] A Per-sample Digitized Algorithm for Automatically Detecting Apnea and Hypopnea Events from Airflow and Oximetry
    Uddin, Md B.
    Chow, Chin Moi
    Ling, Sai H.
    Su, Steven W.
    [J]. 42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 5339 - 5342
  • [2] A novel algorithm for automatic diagnosis of sleep apnea from airflow and oximetry signals
    Uddin, M. B.
    Chow, C. M.
    Ling, S. H.
    Su, S. W.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2021, 42 (01)
  • [3] Airflow from nasal pulse oximetry in the screening of obstructive sleep apnea
    Hoppenbrouwer, Xenia L. R.
    Fabius, T.
    Eijsvogel, M.
    de Jongh, F.
    Garde, A.
    [J]. 2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 2572 - 2575
  • [4] Diagnosis of pediatric obstructive sleep apnea: Preliminary findings using automatic analysis of airflow and oximetry recordings obtained at patients' home
    Gutierrez-Tobal, Gonzalo C.
    Luz Alonso-Alvarez, M.
    Alvarez, Daniel
    del Campo, Felix
    Teran-Santos, Joaquin
    Hornero, Roberto
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2015, 18 : 401 - 407
  • [5] Comparison between a Single-Channel Nasal Airflow Device and Oximetry for the Diagnosis of Obstructive Sleep Apnea
    Rofail, Lydia Makarie
    Wong, Keith K. H.
    Unger, Gunnar
    Marks, Guy B.
    Grunstein, Ronald R.
    [J]. SLEEP, 2010, 33 (08) : 1106 - 1114
  • [6] An explainable deep-learning architecture for pediatric sleep apnea identification from overnight airflow and oximetry signals
    Jimenez-Garcia, Jorge
    Garcia, Maria
    Gutierrez-Tobal, Gonzalo C.
    Kheirandish-Gozal, Leila
    Vaquerizo-Villar, Fernando
    Alvarez, Daniel
    del Campo, Felix
    Gozal, David
    Hornero, Roberto
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2024, 87
  • [7] A classification algorithm based on spectral features from nocturnal oximetry and support vector machines to assist in the diagnosis of obstructive sleep apnea
    Victor Marcos, J.
    Hornero, Roberto
    Alvarez, Daniel
    Del Campo, Felix
    Zamarron, Carlos
    [J]. 2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 5547 - +
  • [8] Statistical and Nonlinear Analysis of Oximetry from Respiratory Polygraphy to Assist in the Diagnosis of Sleep Apnea in Children
    Alvarez, Daniel
    Gutierrez-Tobal, Gonzalo C.
    Alonso, Maria L.
    Teran, Joaqui
    del Campo, Felix
    Hornero, Roberto
    [J]. 2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 1860 - 1863
  • [9] A bimodal feature fusion convolutional neural network for detecting obstructive sleep apnea/hypopnea from nasal airflow and oximetry signals
    Peng, Dandan
    Yue, Huijun
    Tan, Wenjun
    Lei, Wenbin
    Chen, Guozhu
    Shi, Wen
    Zhang, Yanchun
    [J]. ARTIFICIAL INTELLIGENCE IN MEDICINE, 2024, 150
  • [10] Utility of approximate entropy from overnight pulse oximetry data in the diagnosis of the obstructive sleep apnea syndrome
    Hornero, Roberto
    Alvarez, Daniel
    Abasolo, Daniel
    del Campo, Felix
    Zamarron, Carlos
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (01) : 107 - 113