Multiphase Pseudocontinuous Arterial Spin Labeling (MP-PCASL) for Robust Quantification of Cerebral Blood Flow

被引:92
|
作者
Jung, Youngkyoo [1 ,2 ]
Wong, Eric C. [1 ,2 ,3 ]
Liu, Thomas T. [1 ,2 ]
机构
[1] Univ Calif San Diego, Ctr Funct MRI, La Jolla, CA 92093 USA
[2] Univ Calif San Diego, Dept Radiol, La Jolla, CA 92093 USA
[3] Univ Calif San Diego, Dept Psychiat, La Jolla, CA 92093 USA
基金
美国国家卫生研究院;
关键词
blood perfusion; arterial spin labeling; pseudocontinuous tagging; cerebral blood flow; multi phase tagging; RELAXATION-TIME; PERFUSION; MRI; INVERSION; BRAIN;
D O I
10.1002/mrm.22465
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Pseudocontinuous arterial spin labeling (PCASL) has been demonstrated to provide the sensitivity of the continuous arterial spin labeling method while overcoming many of the limitations of that method. Because the specification of the phases in the radiofrequency pulse train in PCASL defines the tag and control conditions of the flowing arterial blood, its tagging efficiency is sensitive to factors, such as off-resonance fields, that induce phase mismatches between the radiofrequency pulses and the flowing spins. As a result, the quantitative estimation of cerebral blood flow with PCASL can exhibit a significant amount of error when these factors are not taken into account. In this paper, the sources of the tagging efficiency loss are characterized and a novel PCASL method that utilizes multiple phase offsets is proposed to reduce the tagging efficiency loss in PCASL. Simulations are performed to evaluate the feasibility and the performance of the proposed method. Quantitative estimates of cerebral blood flow obtained with multiple phase offset PCASL are compared to estimates obtained with conventional PCASL and pulsed arterial spin labeling. Our results show that multiple phase offset PCASL provides robust cerebral blood flow quantification while retaining much of the sensitivity advantage of PCASL. Magn Reson Med 64:799-810, 2010. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:799 / 810
页数:12
相关论文
共 50 条
  • [1] Sensitivity of Multiphase Pseudocontinuous Arterial Spin Labelling (MP pCASL) Magnetic Resonance Imaging for Measuring Brain and Tumour Blood Flow in Mice
    Buck, Jessica
    Larkin, James R.
    Simard, Manon A.
    Khrapitchev, Alexandre A.
    Chappell, Michael A.
    Sibson, Nicola R.
    CONTRAST MEDIA & MOLECULAR IMAGING, 2018,
  • [2] Pseudocontinuous Arterial Spin Labeling Quantifies Relative Cerebral Blood Flow in Acute Stroke
    Hernandez, Daymara A.
    Bokkers, Reinoud P. H.
    Mirasol, Raymond V.
    Luby, Marie
    Henning, Erica C.
    Merino, Jose G.
    Warach, Steven
    Latour, Lawrence L.
    STROKE, 2012, 43 (03) : 753 - 758
  • [3] Abnormalities of cerebral blood flow in multiple sclerosis: A pseudocontinuous arterial spin labeling MRI study
    Ota, Miho
    Sato, Noriko
    Nakata, Yasuhiro
    Ito, Kimiteru
    Kamiya, Kouhei
    Maikusa, Norihide
    Ogawa, Masafumi
    Okamoto, Tomoko
    Obu, Satoko
    Noda, Takamasa
    Araki, Manabu
    Yamamura, Takashi
    Kunugi, Hiroshi
    MAGNETIC RESONANCE IMAGING, 2013, 31 (06) : 990 - 995
  • [4] Pseudocontinuous Arterial Spin Labeling with Prospective Motion Correction (PCASL-PROMO)
    Zun, Zungho
    Shankaranarayanan, Ajit
    Zaharchuk, Greg
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (04) : 1049 - 1056
  • [5] Pseudocontinuous arterial spin labeling reveals dissociable effects of morphine and alcohol on regional cerebral blood flow
    Khalili-Mahani, Najmeh
    van Osch, Matthias J. P.
    Baerends, Evelinda
    Soeter, Roelof P.
    de Kam, Marieke
    Zoethout, Remco W. M.
    Dahan, Albert
    van Buchem, Mark A.
    van Gerven, Joop M. A.
    Rombouts, Serge A. R. B.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2011, 31 (05): : 1321 - 1333
  • [6] Multidelay pseudocontinuous arterial spin labeling to measure blood flow in the head and neck
    Sijtsema, Nienke D.
    Petit, Steven F.
    Verduijn, Gerda M.
    Poot, Dirk H. J.
    Warnert, Esther A. H.
    Hoogeman, Mischa S.
    Hernandez-Tamames, Juan A.
    NMR IN BIOMEDICINE, 2023, 36 (07)
  • [7] Accuracy of Parenchymal Cerebral Blood Flow Measurements Using Pseudocontinuous Arterial Spin-Labeling in Healthy Volunteers
    Ambarki, K.
    Wahlin, A.
    Zarrinkoob, L.
    Wirestam, R.
    Petr, J.
    Malm, J.
    Eklund, A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (10) : 1816 - 1821
  • [8] Quantification of Liver Perfusion Using Multidelay Pseudocontinuous Arterial Spin Labeling
    Pan, Xinlei
    Qian, Tianyi
    Fernandez-Seara, Maria A.
    Smith, Robert X.
    Li, Kuncheng
    Ying, Kui
    Sung, Kyunghyun
    Wang, Danny J. J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 43 (05) : 1046 - 1054
  • [9] Quantification of Serial Cerebral Blood Flow in Acute Stroke Using Arterial Spin Labeling
    Harston, George W. J.
    Okell, Thomas W.
    Sheerin, Fintan
    Schulz, Ursula
    Mathieson, Phil
    Reckless, Ian
    Shah, Kunal
    Ford, Gary A.
    Chappell, Michael A.
    Jezzard, Peter
    Kennedy, James
    STROKE, 2017, 48 (01) : 123 - +
  • [10] Cerebral blood flow quantification using vessel-encoded arterial spin labeling
    Okell, Thomas W.
    Chappell, Michael A.
    Kelly, Michael E.
    Jezzard, Peter
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2013, 33 (11): : 1716 - 1724