Transient supercooling behaviors of a novel two-stage Peltier cooler

被引:14
|
作者
Gao, Yan-Wei [1 ,2 ,3 ]
Meng, Jing-Hui [1 ,2 ,3 ]
Liu, Hai-Bo [1 ,2 ,3 ]
Chen, Wei-Hsin [4 ]
Wang, Xiao-Dong [1 ,2 ,3 ]
机构
[1] North China Elect Power Univ, State Key Lab Alternate Elect Power Syst Renewabl, Beijing 102206, Peoples R China
[2] North China Elect Power Univ, Res Ctr Engn Thermophys, Beijing 102206, Peoples R China
[3] North China Elect Power Univ, Key Lab Condit Monitoring & Control Power Plant E, Minist Educ, Beijing 102206, Peoples R China
[4] Natl Cheng Kung Univ, Dept Aeronaut & Astronaut, Tainan 701, Taiwan
基金
中国国家自然科学基金;
关键词
Thermoelectric cooler; Supercooling; Cold-end temperature; Variable cross-sectional area; Two-stage; ELECTRICITY COUPLED MODEL; CURRENT PULSE OPERATION; THERMOELECTRIC COOLER; PERFORMANCE; OPTIMIZATION; GENERATOR; DEVICES; MODULE;
D O I
10.1016/j.applthermaleng.2018.07.100
中图分类号
O414.1 [热力学];
学科分类号
摘要
A new design concept is proposed to enhance the transient supercooling performance, in which variable leg cross-sectional areas are introduced into two-stage TECs. Since the cross-sectional area ratios of hot end to cold end for the hot stage (gamma(h)) and the cold stage (gamma(c)) can be larger, smaller, or equals than/to 1, nine designs with various combinations of gamma(h) and gamma(c) are investigated. A three-dimensional multiphysics model is used to compare the transient supercooling performance of the nine designs at various pulse amplitudes and widths. The results show that as compared with the conventional TEC with a constant cross-sectional area, the new design significantly reduces the cold-end temperature (T-cc) and employing variable cross-sectional area in the cold stage is more effective for reducing T than that in the hot stage. Design with gamma(h) > 1 and gamma(c) > 1 yields the lowest T-cc among the nine designs. The reduced T-cc can be attributed to the fact that the variable cross-sectional area makes the current density and thermal resistance asymmetrical such that more Joule heat transports to the hot end due to its larger cross-sectional area. The cooling performance of the design with gamma(h) > 1 and gamma(c) > 1 is additionally enhanced by increasing yh and ye.
引用
收藏
页码:248 / 256
页数:9
相关论文
共 50 条
  • [1] Experimental study on transient supercooling of two-stage thermoelectric cooler
    Li, Wen-Ken
    Chang, Jhih-Hao
    Amani, Mohammad
    Yang, Tien-Fu
    Yan, Wei-Mon
    [J]. CASE STUDIES IN THERMAL ENGINEERING, 2019, 14
  • [2] Numerical analysis for transient supercooling effect of pulse current shapes on a two-stage thermoelectric cooler
    Gao, Yan-Wei
    Shi Cong-Ling
    Wang Xiao-Dong
    [J]. APPLIED THERMAL ENGINEERING, 2019, 163
  • [3] Enhancement of maximum temperature drop across thermoelectric cooler through two-stage design and transient supercooling effect
    Lv, Hao
    Wang, Xiao-Dong
    Meng, Jing-Hui
    Wang, Tian-Hu
    Yan, Wei-Mon
    [J]. APPLIED ENERGY, 2016, 175 : 285 - 292
  • [4] Enhanced Peltier cooling of two-stage thermoelectric cooler via pulse currents
    Gao, Yan-Wei
    Lv, Hao
    Wang, Xiao-Dong
    Yan, Wei-Mon
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 114 : 656 - 663
  • [5] Supercooling of Peltier cooler using a current pulse
    Snyder, GJ
    Fleurial, JP
    Caillat, T
    Yang, RG
    Chen, G
    [J]. JOURNAL OF APPLIED PHYSICS, 2002, 92 (03) : 1564 - 1569
  • [6] Supercooling in a new two-stage thermoelectric cooler design with phase change material and Thomson effect
    Ruiz-Ortega, Pablo Eduardo
    Olivares-Robles, Miguel Angel
    Oca, Olao Yair Enciso-Montes de
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2021, 243
  • [7] Analysis on Transient Characteristics of Series Two-stage Thermoelectric Cooler in Confined Space
    Meng, Fankai
    Xu, Chenxin
    Sun, Yuetong
    [J]. Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2023, 50 (06): : 99 - 107
  • [8] The transient behavior of Peltier junctions pulsed with supercooling
    Mao, J. N.
    Chen, H. X.
    Jia, H.
    Qian, X. L.
    [J]. JOURNAL OF APPLIED PHYSICS, 2012, 112 (01)
  • [9] Development and testing of two-stage evaporative cooler
    Jain, Dilip
    [J]. BUILDING AND ENVIRONMENT, 2007, 42 (07) : 2549 - 2554
  • [10] Performance analysis of a two-stage evaporative cooler
    Jaafarian, Mohammad
    Kazemian, Mohammad Ehsan
    [J]. MECHANICS & INDUSTRY, 2017, 18 (04)