Aerodynamic forces on a high-voltage delta-configuration lattice transmission tower segment

被引:5
|
作者
Oza, Parthesh S. [1 ]
Kumar, Manish [1 ]
Mohapatra, Pranab K. [1 ]
机构
[1] Indian Inst Technol Gandhinagar, Civil Engn Discipline, Gandhinagar 382355, India
关键词
Lattice transmission tower; Cat-head tower; Delta configuration; Wind tunnel tests; Force coefficients; Computational fluid dynamics; Design standards; FLOW-FIELD;
D O I
10.1016/j.jweia.2021.104711
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents a study on aerodynamic properties of the upper segment of a high-voltage delta-configuration (cat-head) lattice transmission tower. These segments have been damaged in recent strong-wind events. A representative 1:100 scale specimen of the segment was subjected to wind tunnel tests. A computational fluid dynamics-based model was developed to simulate experimental observations. These models were extended to consider segments with different properties, and force coefficients in transverse and longitudinal directions were calculated. Further, provisions outlined in five design standards were used to estimate force coefficients for these segments. Wind forces for a segment can be determined by multiplying that computed using ASCE 74 or IEC 60826 by a factor, which is a function of yaw angle and solidity ratio. This factor varies between 1.0 and 1.6 (1.0 and 2.0) for the transverse (longitudinal) direction. Additional analyses revealed that an approximately 100% increase in the gap between adjacent longitudinal faces leads to an approximately 10% increase in the force coefficient, and that the influence of Reynolds number and turbulence parameters is small. Further, introduction of cross-arm led to a less than 10% reduction in the force coefficient for transverse direction; the influence was negligible in the longitudinal direction.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Numerical Simulation Analysis of High-voltage Transmission Tower
    Lin Haixiao
    Ma Xiaochuan
    Cai Wenlong
    EMERGING SYSTEMS FOR MATERIALS, MECHANICS AND MANUFACTURING, 2012, 109 : 480 - +
  • [2] CATHODIC PROTECTION OF HIGH-VOLTAGE TRANSMISSION TOWER FOOTINGS
    FITZGERALD, JH
    KOLB, WH
    MATERIALS PERFORMANCE, 1985, 24 (12) : 30 - 37
  • [3] Finite Element Model Of High-voltage Transmission Tower Confirmed
    Liu, Chuncheng
    Xu, Qiangsheng
    APPLIED MECHANICS AND MECHANICAL ENGINEERING IV, 2014, 459 : 625 - 630
  • [4] Numerical Analysis of the Influence of Tunnel Construction on High-voltage Transmission Tower
    Zhang, Hualin
    Yang, Junsheng
    Yang, Yuanhong
    ADVANCES IN CIVIL ENGINEERING AND ARCHITECTURE INNOVATION, PTS 1-6, 2012, 368-373 : 2521 - 2525
  • [5] Structural topology optimization of high-voltage transmission tower with discrete variables
    H. Y. Guo
    Z. L. Li
    Structural and Multidisciplinary Optimization, 2011, 43 : 851 - 861
  • [6] Structural topology optimization of high-voltage transmission tower with discrete variables
    Guo, H. Y.
    Li, Z. L.
    STRUCTURAL AND MULTIDISCIPLINARY OPTIMIZATION, 2011, 43 (06) : 851 - 861
  • [7] CAPACITY ASSESSMENT OF A HIGH-VOLTAGE LATTICE TOWER UNDER DIFFERENT LOADING PATTERNS
    Paiva, Fabio
    Burros, Rui C.
    7TH INTERNATIONAL CONFERENCE INTEGRITY-RELIABILITY-FAILURE (IRF2020), 2020, : 933 - 934
  • [8] High-voltage transmission tower-line system subjected to disaster loads
    Li Hongnan
    Bai Haifeng
    PROGRESS IN NATURAL SCIENCE-MATERIALS INTERNATIONAL, 2006, 16 (09) : 899 - 911
  • [9] High-voltage transmission tower-line system subjected to disaster loads
    LI Hongnan and BAI Haifeng ( State Key Laboratory of Coastal and Offshore Engineering
    China Railway No. 9 Group Co.
    Progress in Natural Science, 2006, (09) : 899 - 911
  • [10] Finite element model of high-voltage transmission tower environmental sensitivity analysis
    School of Civil Engineering and Architecture, Northeast Dianli University, Jilin
    132012, China
    不详
    110015, China
    Yingyong Jichu yu Gongcheng Kexue Xuebao, 4 (805-814):