Accurate Needle Localization Using Two-Dimensional Power Doppler and B-Mode Ultrasound Image Analyses: A Feasibility Study

被引:13
|
作者
Daoud, Mohammad I. [1 ]
Shtaiyat, Ahmad [1 ]
Zayadeen, Adnan R. [2 ]
Alazrai, Rami [1 ]
机构
[1] German Jordanian Univ, Dept Comp Engn, Amman 11180, Jordan
[2] Jordanian Royal Med Serv, Ultrasound Sect, Amman 11180, Jordan
关键词
ultrasound-guided needle interventions; needle localization; B-mode ultrasound imaging; power Doppler ultrasound imaging; medical ultrasound image and signal processing; CURVILINEAR ULTRASOUND; ENHANCEMENT; NERVE;
D O I
10.3390/s18103475
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Curvilinear ultrasound transducers are commonly used in various needle insertion interventions, but localizing the needle in curvilinear ultrasound images is usually challenging. In this paper, a new method is proposed to localize the needle in curvilinear ultrasound images by exciting the needle using a piezoelectric buzzer and imaging the excited needle using a curvilinear ultrasound transducer to acquire a power Doppler image and a B-mode image. The needle-induced Doppler responses that appear in the power Doppler image are analyzed to estimate the needle axis initially and identify the candidate regions that are expected to include the needle. The candidate needle regions in the B-mode image are analyzed to improve the localization of the needle axis. The needle tip is determined by analyzing the intensity variations of the power Doppler and B-mode images around the needle axis. The proposed method is employed to localize different needles that are inserted in three ex vivo animal tissue types at various insertion angles, and the results demonstrate the capability of the method to achieve automatic, reliable and accurate needle localization. Furthermore, the proposed method outperformed two existing needle localization methods.
引用
收藏
页数:23
相关论文
共 50 条
  • [1] Needle detection using ultrasound B-mode and power Doppler analyses
    Daoud, Mohammad I.
    Abu-Hani, Ayah F.
    Shtaiyat, Ahmad
    Ali, Mostafa Z.
    Alazrai, Rami
    MEDICAL PHYSICS, 2022, 49 (08) : 4999 - 5013
  • [2] Accurate Needle Localization in Two-Dimensional Ultrasound Images
    Daoud, Mohammad I.
    Khraiwesh, Samira
    Zayadeen, Adnan
    Alazrai, Rami
    2017 10TH INTERNATIONAL CONFERENCE ON ELECTRICAL AND ELECTRONICS ENGINEERING (ELECO), 2017, : 578 - 582
  • [3] Real-Time 3D Curved Needle Segmentation Using Combined B-Mode and Power Doppler Ultrasound
    Greer, Joseph D.
    Adebar, Troy K.
    Hwang, Gloria L.
    Okamura, Allison M.
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2014, PT II, 2014, 8674 : 381 - 388
  • [4] B-mode and color Doppler ultrasound imaging for localization of microelectrode in monkey brain
    Tokuno, H
    Hatanaka, N
    Takada, M
    Nambu, A
    NEUROSCIENCE RESEARCH, 2000, 36 (04) : 335 - 338
  • [5] In vivo evaluation of two-dimensional temperature variation in perirenal fat of pigs with B-mode ultrasound
    Fan, Pengfei
    Yin, Chuhao
    Xue, Honghui
    Xie, Linzhou
    Sun, Wei
    Tu, Juan
    Guo, Xiasheng
    Kong, Xiangqing
    Zhang, Dong
    JOURNAL OF APPLIED PHYSICS, 2019, 126 (08)
  • [6] Is three-dimensional power Doppler ultrasound better than two-dimensional power Doppler?
    Guerriero, S
    Ajossa, S
    Melis, G
    GYNECOLOGIC ONCOLOGY, 2002, 84 (02) : 352 - 353
  • [7] Using two methods for recognition common carotid artery of B-mode longitudinal ultrasound image
    Wan, Jun
    Ruan, Qiuqi
    Li, Wei
    2010 IEEE 10TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING PROCEEDINGS (ICSP2010), VOLS I-III, 2010, : 1753 - 1756
  • [8] Is three-dimensional power Doppler ultrasound better than two-dimensional power Doppler? Reply
    Fishman, DA
    Cohen, L
    GYNECOLOGIC ONCOLOGY, 2002, 84 (02) : 353 - 353
  • [9] USEFULNESS OF B-MODE AND POWER DOPPLER ULTRASOUND TO DIAGNOSE A RARE CASE OF NEUROVASCULAR CONFLICT
    Piccinini, G.
    Coraci, D.
    Lodispoto, F.
    Cambise, C.
    Giovannini, S.
    Vulpiani, M.
    Padua, L.
    JOURNAL OF THE PERIPHERAL NERVOUS SYSTEM, 2018, 23 : S33 - S34
  • [10] Automatic needle segmentation in three-dimensional ultrasound images using two orthogonal two-dimensional image projections
    Ding, MY
    Cardinal, HN
    Fenster, A
    MEDICAL PHYSICS, 2003, 30 (02) : 222 - 234