In vivo 1H MRS in the assessment of the therapeutic response of breast cancer patients

被引:35
|
作者
Sharma, Uma [1 ,2 ]
Baek, Hyeon Man [3 ]
Su, Min Ying [4 ]
Jagannathan, Naranamangalam R. [1 ,2 ]
机构
[1] All India Inst Med Sci, Dept NMR, New Delhi 110029, India
[2] All India Inst Med Sci, MRI Facil, New Delhi 110029, India
[3] Univ Texas SW Med Ctr Dallas, Dept Radiol, Dallas, TX 75390 USA
[4] Univ Calif Irvine, Tu & Yuen Ctr Funct Oncoimaging, Irvine, CA USA
关键词
MRS; breast cancer; therapeutic response; total choline (tCho); water-to-fat (W-F) ratio; signal-to-noise ratio (SNR); quantification; tumor volume; PREDICTING PATHOLOGICAL RESPONSE; MAGNETIC-RESONANCE-SPECTROSCOPY; PRIMARY SYSTEMIC THERAPY; CONTRAST-ENHANCED MRI; NEOADJUVANT CHEMOTHERAPY; PREOPERATIVE CHEMOTHERAPY; TUMOR RESPONSE; LESIONS; CHOLINE; QUANTIFICATION;
D O I
10.1002/nbm.1654
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
MRI and in vivo MRS have rapidly evolved as sensitive tools for diagnosis and therapeutic monitoring in cancer research. in vivo MRS provides information on tumor metabolism, which is clinically valuable in the diagnosis and assessment of tumor response to therapy for the management of women with breast diseases. Several centers complement breast MRI studies with H-1 MRS to improve the specificity of diagnosis. Malignant breast tissues show elevated water-to-fat ratio and choline-containing compounds (total choline, tCho), and any effect of therapy on tissue viability or metabolism will be manifested as changes in these levels. Sequential H-1 MRS studies have shown significantly reduced tCho levels during the course of therapy in patients who were responders. However, there are challenges in using in vivo MRS because of the relatively low sensitivity in detecting the tCho resonance with decreased lesion size or significant reduction in the tumor volume during therapy. MRS is also technically challenging because of the low signal-to-noise ratio and heterogeneous distribution of fat and glandular tissues in the breast. MRS is best utilized for the diagnosis of focal masses, most commonly seen in patients with ductal-type neoplasms; however, it has limitations in detecting nonfocal masses, such as the linear pattern of tumors seen in invasive lobular carcinoma. Further work is required to assess the clinical utility of quantitative MRS, with the goal of automation, which will reduce the subjectivity currently inherent in both qualitative and semi-quantitative MRS. Copyright (C) 2011 John Wiley & Sons, Ltd.
引用
收藏
页码:700 / 711
页数:12
相关论文
共 50 条
  • [1] Monitoring response to breast cancer treatment using 4 tesla 1H MRS
    Baker, E
    DelaBarre, L
    Bolan, PJ
    Merkle, H
    Everson, LI
    Garwood, M
    RADIOLOGY, 2001, 218 (02) : 609 - 609
  • [2] Assessment of early docetaxel response in an experimental model of human breast cancer using DCE-MRI, ex vivo HR MAS, and in vivo 1H MRS
    Jensen, Line R.
    Huuse, Else M.
    Bathen, Tone F.
    Goa, Pal E.
    Bofin, Anna M.
    Pedersen, Tina B.
    Lundgren, Steinar
    Gribbestad, Ingrid S.
    NMR IN BIOMEDICINE, 2010, 23 (01) : 56 - 65
  • [3] Specificity of choline metabolites for in vivo diagnosis of breast cancer using 1H MRS at 1.5 T
    Peter Stanwell
    Laurence Gluch
    David Clark
    Boguslaw Tomanek
    Luke Baker
    Bruno Giuffrè
    Cynthia Lean
    Peter Malycha
    Carolyn Mountford
    European Radiology, 2005, 15 : 1037 - 1043
  • [4] Specificity of choline metabolites for in vivo diagnosis of breast cancer using 1H MRS at 1.5 T
    Stanwell, P
    Gluch, L
    Clark, D
    Tomanek, B
    Baker, L
    Giuffrè, B
    Lean, C
    Malycha, P
    Mountford, C
    EUROPEAN RADIOLOGY, 2005, 15 (05) : 1037 - 1043
  • [5] In vivo 1H MRS of normal breast and breast tumors using a dedicated double breast coil
    Gribbestad, IS
    Singstad, TE
    Nilsen, G
    Fjosne, HE
    Engan, T
    Haugen, OA
    Rinck, PA
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (06) : 1191 - 1197
  • [6] Neurometabolite and cognitive changes in hypothyroid patients in response to treatment: In-vivo 1H MRS study
    Kumar, Mukesh
    Singh, Sadhana
    Rana, Poonam
    D'souza, Maria
    Kumaran, S. Senthil
    Sekhri, Tarun
    Khushu, Subash
    NEUROCHEMISTRY INTERNATIONAL, 2025, 182
  • [7] Characterizing Human Cancer Metabolomics with ex vivo 1H HRMAS MRS
    DeFeo, Elita M.
    Cheng, Leo L.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2010, 9 (04) : 381 - 391
  • [8] Assessment and optimization of TEA-PRESS sequences in 1H MRS and MRSI of the breast
    Karatopis, A.
    Anastasopoulos, S.
    Drakopoulos, S.
    Douskou, M.
    Panagiotakis, G. S.
    Kandarakis, I.
    2008 IEEE INTERNATIONAL WORKSHOP ON IMAGING SYSTEMS AND TECHNIQUES, 2008, : 295 - +
  • [9] Effect of contrast agent on the results of in vivo 1H MRS of breast tumors - is it clinically significant?
    Baltzer, Pascal A. T.
    Gussew, Alexander
    Dietzel, Matthias
    Rzanny, Reinhard
    Gajda, Mieczyslaw
    Camara, Oumar
    Reichenbach, Jurgen R.
    Kaiser, Werner A.
    NMR IN BIOMEDICINE, 2012, 25 (01) : 67 - 74
  • [10] 1H MRS of human brain abscesses in vivo and in vitro
    Unite INSERM 438 , Hopital Albert Michallon, F 38043 Grenoble Cedex 9, France
    MAGN. RESON. MED., 4 (508-514):