The risk management of medical device-related pressure ulcers based on the Australian/New Zealand Standard

被引:17
|
作者
Chen, Lijuan [1 ]
机构
[1] Xiamen Univ, Dept Gen Surg, Zhongshan Hosp, 201 South Hubin Rd, Xiamen 361000, Fujian, Peoples R China
关键词
Medical device-related pressure ulcers (MDRPUs); AS/NZS; 4360/2004; standard; risk management;
D O I
10.1177/0300060518786902
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective: To analyse medical device-related pressure ulcer (MDRPU) management modes and their possible risks and provide references to treat MDRPUs. Methods: The Australian/New Zealand Standard (AS/NZS) 4360:2004 risk management standard is the first national risk management standard in the world. Zhongshan Hospital adopted the standard to establish risk management modes to improve the MDRPU risk management process and to register, assess and analyse the key risks for MDRPUs. Eight risk types were identified and registered: organization management risk, environment risk, patient safety risk, human resource risk, infection risk, occupational safety risk, legal risk and reputational risk. Results: Following the implementation of the AS/NZS 4360:2004 risk management standard in our institution, the organization management risk value decreased from 25 to 5; the environment risk value decreased from 25 to 5; the patient safety risk value decreased from 20 to 3; the human resource risk value decreased from 16 to 4; the infection risk value decreased from 9 to 1; the occupational risk value decreased from 9 to 6; the legal risk value decreased from 9 to 4; and the reputational risk value decreased from 12 to 2. Conclusion: The AS/NZS 4360:2004 risk management standard was effective in managing the risk of MDRPUs.
引用
收藏
页码:4129 / 4139
页数:11
相关论文
共 50 条
  • [1] A new consensus on medical device-related pressure ulcers
    Gefen, Amit
    JOURNAL OF WOUND CARE, 2019, 28 (06) : 315 - 315
  • [2] Medical device-related pressure ulcers
    Black, Joyce M.
    Kalowes, Peggy
    CHRONIC WOUND CARE MANAGEMENT AND RESEARCH, 2016, 3 : 91 - 99
  • [3] MEDICAL DEVICE-RELATED PRESSURE ULCERS IN JAPAN
    Sugama, J.
    Takeda, T.
    Sanada, H.
    WOUND REPAIR AND REGENERATION, 2016, 24 (06) : A7 - A7
  • [4] Medical Device-Related Pressure Ulcers and Intensive Care Patients
    Makic, Mary Beth Flynn
    JOURNAL OF PERIANESTHESIA NURSING, 2015, 30 (04) : 336 - 337
  • [5] Bioengineering considerations in the prevention of medical device-related pressure ulcers
    Bader, D. L.
    Worsley, P. R.
    Gefen, A.
    CLINICAL BIOMECHANICS, 2019, 67 : 70 - 77
  • [6] IMMOBILITIY-RELATED AND MEDICAL DEVICE-RELATED PRESSURE ULCERS IN PEDIATRIC PATIENTS
    Quigley, Sandy
    Kulik, Lindyce
    McCabe, Margaret
    Caillouette, Catherine Noonan
    Micalizzi, Rosella
    Murphy, Jane
    Hamilton, Susan
    Wells, Sarah
    Costello, Caroline
    Nobrega, Janelle
    Hasbani, Natalie
    Curley, Martha A. Q.
    JOURNAL OF WOUND OSTOMY AND CONTINENCE NURSING, 2016, 43 (03) : S85 - S85
  • [7] INCIDENCE OF MEDICAL DEVICE-RELATED PRESSURE ULCERS AMONG HOSPITALIZED PATIENTS
    Lyu, Ji Yan
    Hsu, Mei Yu
    Chang, Shu-Shang
    JOURNAL OF WOUND OSTOMY AND CONTINENCE NURSING, 2016, 43 (03) : S78 - S78
  • [8] A prospective window into medical device-related pressure ulcers in intensive care
    Coyer, Fiona M.
    Stotts, Nancy A.
    Blackman, Virginia Schmied
    INTERNATIONAL WOUND JOURNAL, 2014, 11 (06) : 656 - 664
  • [9] Incidence and risk factors for medical device-related pressure ulcers: The first report in this regard in Iran
    Rashvand, Farnoosh
    Shamekhi, Lida
    Rafiei, Hossein
    Nosrataghaei, Mohammad
    INTERNATIONAL WOUND JOURNAL, 2020, 17 (02) : 436 - 442
  • [10] DEVICE-RELATED PRESSURE ULCERS! THEY CAN BE STOPPED!
    Owens, Lisa K.
    JOURNAL OF WOUND OSTOMY AND CONTINENCE NURSING, 2014, 41 : S66 - S66