Use of lag screws for fractures of the mandibular body

被引:14
|
作者
Ellis, E
机构
[1] Oral and Maxillofacial Surgery, Univ. Texas Southwestern Med. Ctr., Dallas, TX
[2] Univ. Texas Southwestern Med. Ctr., Dallas, TX 75235-9109
关键词
D O I
10.1016/S0278-2391(96)90489-9
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This article presents the results of treating fractures of the mandibular body using lag screws alone or lag screws inserted through bone plates. Patients and Methods: Thirty-one patients treated for fractures of the mandibular body using lag screws within a 5.5-year period were retrospectively studied for complications. Nine patients were treated with lag screws only and 22 with a lag screw inserted through a bone plate. No patient was placed into postsurgical maxillomandibular fixation. Results: There were no intraoperative or postoperative complications, except for one dental abscess. Conclusions: Lag screw fixation of mandibular body fractures is a reliable technique when these is sufficient obliquity of the fracture.
引用
收藏
页码:1314 / 1316
页数:3
相关论文
共 50 条
  • [1] THE USE OF LAG SCREWS IN MANDIBULAR FRACTURES
    LEONARD, MS
    OTOLARYNGOLOGIC CLINICS OF NORTH AMERICA, 1987, 20 (03) : 479 - 493
  • [2] OSTEOSYNTHESIS OF MANDIBULAR FRACTURES USING LAG SCREWS
    NIEDERDELLMANN, H
    SCHILLI, W
    DUKER, J
    AKUAMOABOATENG, E
    INTERNATIONAL JOURNAL OF ORAL SURGERY, 1976, 5 (03): : 117 - 121
  • [3] Use of lag screws for the management of mandibular trauma
    Zachariades, N
    Mezitis, M
    Papademetriou, I
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1996, 81 (02): : 164 - 167
  • [4] The Outcomes of the Lag-Screw Use for Treatment of the Mandibular Symphysis, Parasymphysis and Oblique Body Fractures
    Abd-Alwahab, Hani Tareq
    Hassan, Thair A. Lateef
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2021, 9 (06): : 44 - 53
  • [5] A comparative study between traditional fixation with miniplates and modified lag screws for the treatment of mandibular fractures
    Ana Rocío García Carricondo
    Francisco Javier Quesada Bravo
    Fernando Espín Gálvez
    Tesifón Parrón Carreño
    Raquel Alarcón Rodriguez
    Clinical Oral Investigations, 2018, 22 : 1503 - 1511
  • [6] A comparative study between traditional fixation with miniplates and modified lag screws for the treatment of mandibular fractures
    Garcia Carricondo, Ana Rocio
    Quesada Bravo, Francisco Javier
    Espin Galvez, Fernando
    Parron Carreno, Tesifon
    Alarcon Rodriguez, Raquel
    CLINICAL ORAL INVESTIGATIONS, 2018, 22 (03) : 1503 - 1511
  • [7] A comparative evaluation of osteosynthesis with lag screws, miniplates, or Kirschner wires for mandibular condylar process fractures
    Sugiura, T
    Yamamoto, K
    Murakami, K
    Sugimura, M
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2001, 59 (10) : 1161 - 1168
  • [8] Lag-screw fixation of anterior mandibular fractures using biodegradable polylactide screws: A preliminary report
    Kallela, I
    Iizuka, T
    Salo, A
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1999, 57 (02) : 113 - 118
  • [9] A comparative evaluation of osteosynthesis with lag screws, miniplates, or Kirschner wires for mandibular condylar process fractures - Discussion
    Santler, G
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2001, 59 (10) : 1169 - 1170
  • [10] Assessment of Lag Screws in Treatment of Anterior Mandibular Fracture
    Chowdhury, Esha
    Ebenezer, Vijay
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2024, 16 (SUPPL 4) : S3194 - S3196