摘要
The SeedLink(TM) brachytherapy system is comprised from an assembly of I-Plant(TM) 3500 interstitial brachytherapy seeds and bioresorbable spacers joined together by a 6-mm-long titanium sleeve centered over each seed. This device is designed to maintain specified spacing between seeds during treatment thereby decreasing implant preparation time and reducing radionuclide migration within the prostate and periprostatic region. Reliable clinical treatment and planning applications necessitate accurate dosimetric data for source evaluation, therefore the authors report the results of a Monte Carlo study designed to calculate the AAPM Task Group Report No. 43 dosimetric parameters for the SeedLink brachytherapy source and compare these values against previously published Monte Carlo study results of the I-Plant 3500 brachytherapy seed. For this investigation, a total of 1 X 10(9) source photon histories were processed for each set of in-water and in-air calculations using the MCNP4C2 Monte Carlo radiation transport code (RSICC). Statistically, the radial dose function, g(r), and the dose-rate constant, Lambda, were identical to the values calculated previously for the Model 3500 with the dose-rate constant evaluated to be Lambda=1.000+/-0.026 cGyh(-1) U-1. The titanium sleeve used in SeedLink to bind together Model 3500 seeds and spacers resulted in slightly greater dosimetric anisotropy as exhibited in the anisotropy function, F(r, theta), the anisotropy factor, phi(an) (r), and the anisotropy constant, (φ) over bar (an), which was calculated to be (φ) over bar (an)=0.91+/-0.01, or roughly 2% lower than the value calculated previously for the Model 3500. These results indicate that the radiological characteristics of the SeedLink dosimetry system are comparable to those obtained for previously characterized single seeds such as the Implant Sciences Model 3500 I-Plant seed. (C) 2003 American Association of Physicists in Medicine.
引用
收藏
页码:2503 / 2508
页数:6
相关论文
共 50 条
  • [1] Monte Carlo calculation of the relative TG-43 dosimetry parameters for the INTRABEAM electronic brachytherapy source
    Alvarez, David Santiago Ayala
    Watson, Peter G. F.
    Popovic, Marija
    Heng, Veng Jean
    Evans, Michael D. C.
    Seuntjens, Jan
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (24):
  • [2] An EGSnrc Monte Carlo-calculated database of TG-43 parameters
    Taylor, R. E. P.
    Rogers, D. W. O.
    [J]. MEDICAL PHYSICS, 2008, 35 (09) : 4228 - 4241
  • [3] MONTE CARLO SIMULATION AND TG-43 PARAMETERS FOR THE 125I NUCLETRON SELECTSEED BRACHYTHERAPY SOURCE
    Juan-Senabre, X. J.
    Porras, I.
    Lallena, A. M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S175 - S175
  • [4] Monte Carlo calculation of the TG-43 dosimetry parameters for the INTRABEAM source with spherical applicators
    Alvarez, David Santiago Ayala
    Watson, Peter G. F.
    Popovic, Marija
    Heng, Veng Jean
    Evans, Michael D. C.
    Seuntjens, Jan
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (21):
  • [5] Benchmarking BrachyDose: Voxel based EGSnrc Monte Carlo calculations of TG-43 dosimetry parameters
    Taylor, R. E. P.
    Yegin, G.
    Rogers, D. W. O.
    [J]. MEDICAL PHYSICS, 2007, 34 (02) : 445 - 457
  • [6] DOSIMETRY COMPARISON BETWEEN TG-43 AND MONTE CARLO CALCULATIONS USING THE FREIBURG FLAP FOR SKIN HDR BRACHYTHERAPY
    Vijande, J.
    Ballester, F.
    Domingo, G.
    Ouhib, Z.
    Pujades, M. D. C.
    Perez-Calatayud, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S274 - S274
  • [7] Experimental and Monte Carlo determination of the TG-43 dosimetric parameters for the model 9011 THINSeed™ brachytherapy source
    Kennedy, R. M.
    Davis, S. D.
    Micka, J. A.
    DeWerd, L. A.
    [J]. MEDICAL PHYSICS, 2010, 37 (04) : 1681 - 1688
  • [8] Brachytherapy TG-43 dosimetry characterization of the INTRABEAM source
    Alvarez, D. S. Ayala
    Watson, P. G. F.
    Popovic, M.
    Heng, V. J.
    Evans, M. D. C.
    Seuntjens, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2021, 158 : S97 - S99
  • [9] A modern Monte Carlo investigation of the TG-43 dosimetry parameters for an 125I seed already having AAPM consensus data
    Aryal, Prakash
    Molloy, Janelle A.
    Rivard, Mark J.
    [J]. MEDICAL PHYSICS, 2014, 41 (02)
  • [10] Consideration of the updated TG-43 brachytherapy dosimetry formalism
    Rivard, MJ
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 71 : S13 - S13