Low-intensity pulsed ultrasound initiates bone healing in rat nonunion fracture model

被引:78
|
作者
Takikawa, S
Matsui, N
Kokubu, T
Tsunoda, M
Fujioka, H
Mizuno, K
Azuma, Y
机构
[1] Kobe Univ, Sch Med, Dept Orthoped Surg, Chuo Ku, Kobe, Hyogo 6500017, Japan
[2] Teijin Ltd, Teijin Inst Biochem Res, Tokyo, Japan
关键词
low-intensity pulsed ultrasound; rat nonunion model; fracture healing; three-dimensional microfocus computed tomography;
D O I
10.7863/jum.2001.20.3.197
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Low-intensity pulsed ultrasound exposure has been shown clinically to shorten the fracture repair process and to induce healing of nonunions in humans, but its mechanism of action remains unclear. In this study we investigated the effect and mechanism of low-intensity pulsed ultrasound on nonunion fracture healing in rat tibias. A consistently reproducible nonunion was produced in rat tibias by muscle interposition without osteotomy This model was produced by creating a closed tibial fracture with only the distal end of the tibialis anterior muscle interposed into the fracture site. One limb was noninvasively exposed to low-intensity pulsed ultrasound (a 200-millisecond burst of sine waves of 1.5 MHz, repeating at 1.0 kHz) for 20 minutes daily. The incident intensity was approximately 30 mW/cm(2). Rats were killed at intervals between 2 and 6 weeks. The events were assessed by radiographs, microfocus X-ray computed tomograms, and histologic examination. After 6 weeks of exposure, 7 of 14 nonunion fractures showed healing on radiologic assessment. The results of three-dimensional microfocus X-ray computed tomographic reconstruction and histologic examination also supported this finding. On the other hand, all control tibias remained in a state of nonunion during the same period. These results indicate that low-intensity pulsed ultrasound promotes healing in the rat nonunion fracture model.
引用
收藏
页码:197 / 205
页数:9
相关论文
共 50 条
  • [1] Low-intensity pulsed ultrasound: Fracture healing
    Mundi, Raman
    Petis, Stephen
    Kaloty, Roopinder
    Shetty, Vijay
    Bhandari, Mohit
    [J]. INDIAN JOURNAL OF ORTHOPAEDICS, 2009, 43 (02) : 132 - 140
  • [2] Low-intensity pulsed ultrasound for bone healing: An overview
    Malizos, Konstantinos N.
    Hantes, Michael E.
    Protopappas, Vassilios
    Papachristos, Athanasios
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2006, 37 : S56 - S62
  • [3] Fracture healing using low-intensity pulsed ultrasound - Response
    Busse, JW
    Bhandari, M
    Kulkarni, AV
    [J]. CANADIAN MEDICAL ASSOCIATION JOURNAL, 2002, 167 (02) : 128 - 128
  • [4] LOW-INTENSITY PULSED ULTRASOUND FOR THE TREATMENT OF BONE DELAYED UNION OR NONUNION: A REVIEW
    Romano, Carlo L.
    Romano, Delia
    Logoluso, Nicola
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2009, 35 (04): : 529 - 536
  • [5] The Effects of Low-Intensity Pulsed Ultrasound Upon Diabetic Fracture Healing
    Coords, Michael
    Breitbart, Eric
    Paglia, David
    Kappy, Nikolas
    Gandhi, Ankur
    Cottrell, Jessica
    Cedeno, Natalie
    Pounder, Neill
    O'Connor, J. Patrick
    Lin, Sheldon S.
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2011, 29 (02) : 181 - 188
  • [6] How does pulsed low-intensity ultrasound enhance fracture healing?
    Stein, H
    Lerner, A
    [J]. ORTHOPEDICS, 2005, 28 (10) : 1161 - 1163
  • [7] Fracture Nonunion Treated with Low-Intensity Pulsed Ultrasound and Monitored with Ultrasonography: A Feasibility Study
    Zhang, Peizhen
    Li, Pengdong
    Liao, Shihai
    Li, Xuan
    Chen, Wufan
    Wang, Xiaoyun
    Wang, Qing
    [J]. BIOMED RESEARCH INTERNATIONAL, 2021, 2021
  • [8] Low-Intensity Pulsed Ultrasound Therapy: A Nonsurgical Treatment Modality for Mandible Fracture Nonunion?
    Abel, Adam R.
    Reeve, Gwendolyn S.
    [J]. FACIAL PLASTIC SURGERY, 2021, 37 (05) : 571 - 575
  • [9] Effects of low-intensity pulsed ultrasound on autogenous bone graft healing
    Findik, Yavuz
    Baykul, Timucin
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2014, 117 (03): : E255 - E260
  • [10] Effect of the low-intensity pulsed ultrasound therapy on healing of Achilles tendinopathy in a rat model
    Kurtulmus, Tuhan
    Celebi, Mehmet Emin
    Bektas, Ebubekir
    Arican, Cigdem Dicle
    Kucukyildirim, Bedri Onur
    Demirkol, Metehan
    [J]. ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2024, 58 (02)