Experimental investigation of steel built-up beam-columns composed of tracks and channels cold-formed sections

被引:6
|
作者
El Hady, A. M. [1 ,2 ]
El Aghoury, M. A. [2 ]
Ibrahim, S. M. [2 ]
Amoush, E. A. [1 ]
机构
[1] Higher Technol Inst, Civil Engn Dept, 10Th Of Ramadan City, Egypt
[2] Ain Shams Univ, Fac Engn, Struct Engn Dept, Cairo, Egypt
来源
关键词
Built-up section; Cold-formed steel; Column; Beam-columns; Finite element; Eccentric loading; DOUBLE-Z MEMBERS; I-SECTION; BEHAVIOR; CAPACITY; BOX;
D O I
10.1016/j.jobe.2022.104295
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, a built-up column of novel cold-formed cross-section that composed of four elements is investigated. The proposed built-up column is suitable for carrying axial, uni-axial, and bi-axial loading. The web of the new cross-section is composed of back-to-back track sections while the flanges of the cross-section are two lipped channels connected to the web using interconnectors. Elements comprising the cross-section are assembled and connected by enough interconnector bolts depending on the column built-up configurations. The interconnector spacing is varied among specimen cross-section and column length. In the present study, series of axially, uni-axially, and bi-axially compression columns were tested experimentally. Eleven specimens with various cross-section aspect ratios as well as different overall slenderness ratios were tested. Numerical finite element model that accounts for both material and geometrical nonlinearities was developed using 'ABAQUS' software to analyze the tested columns. A good agreement was achieved between the experimental test and the finite element model results. Experimental test results revealed that for axially loaded columns with small, medium, and high slenderness ratios, the failure modes were local buckling, local-flexural buckling, and flexural distortional buckling; respectively. On the other hand, for uni-axially loaded columns having small, medium, and high slenderness ratios, the failure modes were local buckling, interaction between local and lateral-torsional buckling as well as lateral-torsional buckling; respectively. Furthermore, for bi-axially loaded columns, the failure mode was lateral-torsional buckling.
引用
收藏
页数:25
相关论文
共 50 条
  • [1] Investigation of built-up box columns composed of four cold-formed steel channels
    Nie, Shaofeng
    Eatherton, Matthew R.
    Han, Yong
    Zhou, Tianhua
    Wu, Hanheng
    Li, Jiang
    THIN-WALLED STRUCTURES, 2022, 175
  • [2] Numerical investigation of steel built-up columns composed of track and channel cold-formed sections
    El Aghoury, M. A.
    Amoush, E. A.
    El Hady, A. M.
    Ibrahim, S. M.
    STABILITY AND DUCTILITY OF STEEL STRUCTURES 2019, 2019, : 363 - 370
  • [3] Tests of cold-formed steel built-up open section beam-columns
    Li, Qiu-Yun
    Young, Ben
    ADVANCES IN ENGINEERING MATERIALS, STRUCTURES AND SYSTEMS: INNOVATIONS, MECHANICS AND APPLICATIONS, 2019, : 1077 - 1082
  • [4] Structural behaviour of cold-formed steel built-up closed section beam-columns
    Li, Qiu-Yun
    Young, Ben
    THIN-WALLED STRUCTURES, 2022, 181
  • [5] Experimental investigation of the sectional buckling of built-up cold-formed steel columns
    Abbasi, Mandana
    Rasmussen, Kim J. R.
    Khezri, Mani
    Schafer, Benjamin W.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2023, 203
  • [6] Experimental study of cold-formed steel built-up columns
    Meza, Francisco J.
    Becque, Jurgen
    Hajirasouliha, Iman
    THIN-WALLED STRUCTURES, 2020, 149
  • [7] Experimental investigation of built-up cold-formed steel section battened columns
    Dabaon, Mohamed
    Ellobody, Ehab
    Ramzy, Khaled
    THIN-WALLED STRUCTURES, 2015, 92 : 137 - 145
  • [8] Experimental study on cold-formed steel built-up section beam-columns experiencing non-uniform bending
    Li, Qiu-Yun
    Young, Ben
    ENGINEERING STRUCTURES, 2022, 256
  • [9] Design of built-up steel beam-columns composed of two-channel sections
    Iskander, G.
    Soliman, E.
    Sayed-Ahmed, E.
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2021, 48 (11) : 1508 - 1522
  • [10] Behaviour of cold-formed steel built-up closed columns composed by angle profiles
    Aruna G.
    Sukumar S.