Failure analysis of a Monel-400 heat exchanger tube from a nuclear power plant

被引:0
|
作者
Muralidharan, NG [1 ]
Raghu, N [1 ]
Kasiviswanathan, KV [1 ]
Jayakumar, T [1 ]
Raj, B [1 ]
机构
[1] Indira Gandhi Ctr Atom Res, Met & Mat Grp, Kalpakkam 603102, Tamil Nadu, India
关键词
D O I
暂无
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
Failure of a heat exchanger was reported in one of the nuclear power plants; The plant has eight boilers and each boiler has eleven heat exchanger bundles. The Monel-400 heat exchanger bundles are of U-Tube construction consisting of 192 tubes having 12 mm outer diameter and 1mm wall thickness. The tube sheet of the heat exchanger is made of 65mm thick stainless steel with monel overlay on the outer face. The heat exchanger tubes were fully expanded in the tube sheet and welded on to the outer face of the tube sheet having the monel overlay. The tubeside fluid is heavy water and the shell side fluid is feed water. The failure in the form of a leak was noticed in the particular heat exchanger when routine inspection of the boiler feed water was analyzed. The heat exchanger bundle was cutout of the boiler and the leaky tube was identified by conducting pressurization tests. The failure location was close to the tube sheet at the heavy water inlet end where large amount of sludge deposit was noticed. Detailed failure investigation revealed extensive wall thinning in the failed region. The failure was found to be intergranular in nature and leaching of nickel from the grain boundary region was also observed. The cause of the failure was found to be 'underdeposit' corrosion. Details of the failure investigation carried out are presented in the paper.
引用
收藏
页码:946 / 951
页数:6
相关论文
共 50 条
  • [1] INFLUENCE OF GRAIN SIZE AND HEAT TREATMENT ON CREEP OF MONEL-400
    HAUBER, JR
    SHERBY, OD
    [J]. JOURNAL OF MATERIALS, 1970, 5 (02): : 251 - &
  • [2] Investigation of Heat Annealing and Parametric Optimization for Drilling of Monel-400 Alloy
    Abdo, Basem M. A.
    Almuzaiqer, Redhwan
    Noman, Mohammed A.
    Chintakindi, Sanjay
    [J]. JOURNAL OF MANUFACTURING AND MATERIALS PROCESSING, 2023, 7 (05):
  • [3] A review on tube external heat transfer for passive residual heat removal heat exchanger in nuclear power plant
    Liu, Yanbin
    Wang, Xuesheng
    Meng, Xiangyu
    Wang, Dawei
    [J]. APPLIED THERMAL ENGINEERING, 2019, 149 : 1476 - 1491
  • [4] Classifiability Analysis of Indications by Eddy-Current Testing of Nuclear Power Plant Heat-Exchanger Tube
    Grman, Jan
    Syrova, Livia
    [J]. PROCEEDINGS OF 19TH INTERNATIONAL CONFERENCE RADIOELEKTRONIKA 2009, 2009, : 285 - 288
  • [5] Failure analysis on abnormal bursting of heat transfer tubes in spiral-wound heat exchanger for nuclear power plant
    Yang, Xiao-Lei
    Gong, Yi
    Tong, Qi
    Yang, Zhen-Guo
    [J]. ENGINEERING FAILURE ANALYSIS, 2020, 108 (108)
  • [6] Failure analysis on abnormal leakage of shell and tube heat exchanger in specialty chemical plant
    Ma, Si -Yuan
    Bi, Tong -Tong
    Gong, Yi
    Yang, Zhen-Guo
    [J]. ENGINEERING FAILURE ANALYSIS, 2023, 143
  • [7] EVALUTION OF A HEAT-EXCHANGER TUBE-BANK IN AN NUCLEAR-POWER PLANT FROM THE POINT OF VIEW OF VIBRATION
    NOVAK, J
    [J]. JADERNA ENERGIE, 1984, 30 (01): : 17 - 22
  • [8] Failure analysis of a copper tube in a finned heat exchanger
    Peltola, H.
    Lindgren, M.
    [J]. ENGINEERING FAILURE ANALYSIS, 2015, 51 : 83 - 97
  • [9] Failure analysis on abnormal leakage between tubes and tubesheet of spiral-wound heat exchanger for nuclear power plant
    Yang, Xiao-Lei
    Gong, Yi
    Yang, Zhen-Guo
    [J]. ENGINEERING FAILURE ANALYSIS, 2020, 118
  • [10] Failure Analysis and Overall Maintenance of Recirculation Cooling Water System Heat Exchanger of Third Qinshan Nuclear Power Plant
    CNNC, Nuclear Power Operations Management Co. Ltd., Haiyan
    Zhejiang
    314300, China
    [J]. Hedongli Gongcheng, 4 (112-115):