Real-time detection of common microbial volatile organic compounds from medically important fungi by Selected Ion Flow Tube-Mass Spectrometry (SIFT-MS)

被引:60
|
作者
Scotter, JM
Langford, VS
Wilson, PF
McEwan, MJ [1 ]
Chambers, ST
机构
[1] Univ Canterbury, Dept Chem, Christchurch 1, New Zealand
[2] Univ Otago, Christchurch Sch Med, Dept Pathol, Christchurch, New Zealand
[3] Syft Technol Ltd, Christchurch, New Zealand
关键词
mycology; SIFT-MS; volatiles; detection;
D O I
10.1016/j.mimet.2005.02.022
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We describe a new method, Selected Ion Flow Tube-Mass Spectrometry (SIFT-MS) for the rapid and sensitive real-time detection and quantification of volatile organic compounds from medically important fungi, grown on a range of laboratory media. SIFT-MS utilises the chemical ionisation reactions of mass-selected ions to characterise volatile organic compounds (VOCs) that are produced as metabolites from fungi. This technique has the distinct advantage over others in that it readily detects low molecular weight, reactive volatiles, and allows for real-time, quantitative monitoring. The fungi examined in this study were Aspergillus flavus, Aspergillus fumigatus, Candida albicans, Mucor racemosus, Fusarium solani, and Cryptococcus neoformans grown on or in malt extract agar, Columbia agar, Sabouraud's dextrose agar, blood agar, and brain-heart infusion broth. Common metabolites (ethanol, methanol, acetone, acetaldehyde, methanethiol, and crotonaldehyde) were detected and quantified. We found the fingerprint of volatiles, in terms of presence and quantity of volatiles to be strongly dependent on the culture medium, both in terms of variety and quantity of volatiles produced, but may form the basis for species specific identification of medically important fungi. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:127 / 134
页数:8
相关论文
共 50 条
  • [1] Development of Real-time and Simultaneous Quantification of Volatile Organic Compounds in Ambient with SIFT-MS (Selected Ion Flow Tube-Mass Spectrometry)
    Son, Hyun Dong
    An, Joon Geon
    Ha, Sung Yong
    Kim, Gi Beum
    Yim, Un Hyuk
    JOURNAL OF KOREAN SOCIETY FOR ATMOSPHERIC ENVIRONMENT, 2018, 34 (03) : 393 - 405
  • [2] Detection of volatile compounds produced by microbial growth in urine by selected ion flow tube mass spectrometry (SIFT-MS)
    Storer, Malina K.
    Hibbard-Melles, Kim
    Davis, Brett
    Scotter, Jenny
    JOURNAL OF MICROBIOLOGICAL METHODS, 2011, 87 (01) : 111 - 113
  • [3] Rapid monitoring of volatile organic compounds: selected ion flow tube mass spectrometry (SIFT-MS)
    Sinir, G. Ozcan
    Suna, S.
    Tamer, C. E.
    BULGARIAN CHEMICAL COMMUNICATIONS, 2014, 46 : 103 - 107
  • [4] Selected Ion Flow Tube Mass Spectrometry, SIFT-MS
    Spanel, Patrik
    Smith, David
    CURRENT ANALYTICAL CHEMISTRY, 2013, 9 (04) : 523 - 524
  • [5] Comparison of Tomatillo and Tomato Volatile Compounds in the Headspace by Selected Ion Flow Tube Mass Spectrometry (SIFT-MS)
    Xu, Yichi
    Barringer, Sheryl
    JOURNAL OF FOOD SCIENCE, 2010, 75 (03) : C268 - C273
  • [6] Detecting volatile compounds from Kraft lignin degradation in the headspace of microbial cultures by selected ion flow tube mass spectrometry (SIFT-MS)
    Gibson, Andrew
    Malek, Lada
    Dekker, Robert F. H.
    Ross, Brian
    JOURNAL OF MICROBIOLOGICAL METHODS, 2015, 112 : 40 - 45
  • [7] Comparison of encapsulation of garlic oil with -, -, and -cyclodextrin using Selected Ion Flow Tube-Mass Spectrometry (SIFT-MS)
    Yu, Jiaxin
    Castada, Hardy Z.
    Huang, Xuesong
    Barringer, Sheryl A.
    JOURNAL OF FOOD PROCESSING AND PRESERVATION, 2019, 43 (02)
  • [8] Monitoring of Cocoa Volatiles Produced during Roasting by Selected Ion Flow Tube-Mass Spectrometry (SIFT-MS)
    Huang, Yang
    Barringer, Sheryl A.
    JOURNAL OF FOOD SCIENCE, 2011, 76 (02) : C279 - C286
  • [9] Quantification of volatile metabolites in exhaled breath by selected ion flow tube mass spectrometry, SIFT-MS
    Spanel, Patrik
    Smith, David
    CLINICAL MASS SPECTROMETRY, 2020, 16 : 18 - 24
  • [10] Selected Ion Flow Tube-Mass Spectrometry (SIFT-MS) as an Alternative to Gas Chromatography/Mass Spectrometry (GC/MS) for the Analysis of Cyclohexanone and Cyclohexanol in Plasma
    Hastie, Colin
    Thompson, Adrian
    Perkins, Mark
    Langford, Vaughan S.
    Eddleston, Michael
    Homer, Natalie Z. M.
    ACS OMEGA, 2021, 6 (48): : 32818 - 32822