Polypropylene melt blown nonwovens for plate-type enthalpy exchanger

被引:4
|
作者
Lee, Chang Hwan [1 ]
Kim, Seong Hun [1 ]
Son, Eun Jong [2 ]
Lim, Tae Hwan [1 ]
机构
[1] Hanyang Univ, Dept Fiber & Polymer Engn, Seoul 133791, South Korea
[2] Bucheon Univ, Dept Text Business, Gyeonggi 420735, South Korea
关键词
plate-type enthalpy exchanger; melt blown nonwoven; leakage; air permeability; water vapor transmission rate; HEAT-EXCHANGER; MASS-TRANSFER; MOISTURE TRANSFER; PERFORMANCE;
D O I
10.1007/s13233-012-0014-5
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
An enthalpy exchanger made of melt blown nonwoven fabrics was prepared using various chemical and physical treatments, and its characteristics were compared with those of a paper exchanger. Water vapor transmission rate and air permeability, the major properties that determine enthalpy exchanger index performance, were investigated. Various measurements were conducted as a function of calendering temperature and speed, moisture content absorbance, and water soluble polymer concentration. The optimum conditions for the enthalpy exchanger made of melt blown nonwoven fabrics included 95 A degrees C calendering temperature and 5% poly(vinyl alcohol) concentration. A commercial melt blown type heat exchanger could potentially replace the paper type.
引用
收藏
页码:4 / 9
页数:6
相关论文
共 50 条
  • [1] Polypropylene melt blown nonwovens for plate-type enthalpy exchanger
    Chang Hwan Lee
    Seong Hun Kim
    Eun Jong Son
    Tae Hwan Lim
    [J]. Macromolecular Research, 2012, 20 : 4 - 9
  • [2] PERFORMANCE OF A PLATE-TYPE ENTHALPY EXCHANGER MADE OF PAPER
    Kim, Nae-Hyun
    Song, Gil-Sup
    Lee, Eul-Jong
    Oh, Wang-Kyu
    [J]. ACRA 2009: PROCEEDINGS OF THE 4TH ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING, 2009, : 570 - 575
  • [3] Melt-blown polypropylene nonwovens with lowered flammability
    Boryniec, S
    Wcislo, P
    Nowicka, C
    Galecki, S
    [J]. FIBRES & TEXTILES IN EASTERN EUROPE, 2000, 8 (02) : 66 - 68
  • [4] Melt-Blown Polypropylene Nonwovens with Lowered Flammability
    [J]. Boryniec, S., 2000, Sciendo (08):
  • [5] PERFORMANCE OF A PLATE-TYPE CROSS-FLOW ENTHALPY EXCHANGER MADE OF PAPER
    Lee, Eul-Jong
    Kim, Nae-Hyun
    Song, Kil-Sup
    Cha, Sang-Jin
    Lee, Jung-Pyo
    [J]. PROCEEDINGS OF THE ASME INTERNATIONAL HEAT TRANSFER CONFERENCE - 2010, VOL 4: HEAT TRANSFER MEASUREMENT TECHNIQUES, HEAT TRANSFER EQUIPMENT, THERMOELECTRICS, 2010, : 473 - 478
  • [6] HEAT AND MOISTURE TRANSFER CHARACTERISTICS OF A PLATE-TYPE ENTHALPY EXCHANGER MADE OF PAPER
    Lee, Eul-Jong
    Kim, Nae-Hyun
    Song, Gil-Sub
    Lee, Jung-Pyo
    [J]. INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2011, 19 (01) : 85 - 92
  • [7] HEAT AND MOISTURE TRANSFER CHARACTERISTICS OF A PLATE-TYPE ENTHALPY EXCHANGER MADE OF PAPER
    Lee, J. P.
    Kim, N. H.
    Lee, E. J.
    Song, G. S.
    [J]. 7TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, PROCEEDINGS OF ISHVAC 2011, VOLS I-IV, 2011, : 793 - 798
  • [8] Spunbonded and melt blown nonwovens
    Bitz, K.
    [J]. Nonwovens Industry, 2001, 32 (08): : 46 - 50
  • [9] EFFECT OF TEMPERATURE ON THE STRUCTURE AND FILTRATION PERFORMANCE OF POLYPROPYLENE MELT-BLOWN NONWOVENS
    Cheng, Si
    Muhaiminul, Alam S. M.
    Yue, Zhonghua
    Wang, Yan
    Xiao, Yuanxiang
    Militky, Jiri
    Prasad, Mohanapriya
    Zhu, Guocheng
    [J]. AUTEX RESEARCH JOURNAL, 2021, 21 (02) : 207 - 217
  • [10] Preparation and charging characteristics analysis of hydro charging polypropylene melt-blown nonwovens
    Wu, Yanjin
    Wang, Jiang
    Wang, Hong
    [J]. Fangzhi Xuebao/Journal of Textile Research, 2022, 43 (12): : 29 - 34