Catheter manipulations and the risk of catheter-associated bloodstream infection in neonatal intensive care unit patients

被引:84
|
作者
Mahieu, LM
De Dooy, JJ
Lenaerts, AE
Leven, MM
De Muynck, AO
机构
[1] Univ Antwerp Hosp, Dept Paediat, Div Neonatol, B-2650 Antwerp, Belgium
[2] Univ Antwerp Hosp, Dept Clin Microbiol, B-2650 Antwerp, Belgium
[3] Inst Trop Med, Dept Clin Sci, Antwerp, Belgium
关键词
bloodstream infection; neonates; catheter; cohort studies; manipulation;
D O I
10.1053/jhin.2000.0930
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
A prospective cohort study was performed to evaluate the influence of catheter manipulations on catheter associated bloodstream infection (CABSI) in neonates. Neonates admitted between 1 November 1993 and 31 October 1994 at the neonatal intensive care unit of a university hospital were included in the study. Seventeen episodes of CABSI occurred in 357 central catheters over a period of 3470 catheter-days, with a cumulative incidence of 4.7/100 catheters and an incidence density of 4.9/1000 catheter-days. Patient- and catheter-related risk factors independently associated with CABSI were: catheter hub colonization (odds ratio [OR] = 32.6, 95% confidence interval [95% CI] = 4.3-249), extremely low weight (< 1000 gram) at time of catheter insertion (OR=9.1, 95% CI=1.9-42.2). Catheter manupulations independently associated with CABSI were disinfection of the catheter hub (OR=1.2, 95% CI=1.1-1.3), blood sampling (OR=1.4, 95% CI=1.1-1.8), heparinization (OR=0.9, 95%, CI=0.8-1.0) and antisepsis of exit site (OR=0.9, 95% CI=0.8-1.0). This study indicates that certain manipulations (e.g. blood sampling through the central line) and disconnection of the central venous catheter, which necessitates disinfection of the catheter hub, increase the risk of CABSI, while other procedures (e.g. heparinization and exit site antisepsis), protect against CABSI in neonates. (C) 2001 The Hospital Infection Society.
引用
收藏
页码:20 / 26
页数:7
相关论文
共 50 条
  • [1] Risk factors for central vascular catheter-associated bloodstream infections among patients in a neonatal intensive care unit
    Mahieu, LM
    De Muynck, AO
    Ieven, MM
    De Dooy, JJ
    Goossens, HJ
    Van Reempts, PJ
    [J]. JOURNAL OF HOSPITAL INFECTION, 2001, 48 (02) : 108 - 116
  • [2] Catheter-associated bloodstream infection in the pediatric intensive care unit: A multidisciplinary approach
    Ahmed, Sheikh Sohail
    McCaskey, Marjorie S.
    Bringman, Sarah
    Eigen, Howard
    [J]. PEDIATRIC CRITICAL CARE MEDICINE, 2012, 13 (02) : E69 - E72
  • [3] Incidence and risk factors for catheter-associated bloodstream infections in neonatal intensive care
    Yumani, Dana F. J.
    van den Dungen, Frank A. M.
    van Weissenbruch, Mirjam M.
    [J]. ACTA PAEDIATRICA, 2013, 102 (07) : e293 - e298
  • [4] RISK FACTORS FOR CATHETER-ASSOCIATED BLOODSTREAM INFECTIONS IN PEDIATRIC INTENSIVE CARE UNIT (PICU) PATIENTS
    Aburto, C. A.
    Tanlaleaan, J. A.
    Nakachi, G.
    Acosta, M., I
    [J]. PEDIATRIC RESEARCH, 2009, 65 (04) : 481 - 481
  • [5] Risk of catheter-associated bloodstream infection by catheter type in a neonatal intensive care unit: a large cohort study of more than 1100 intravascular catheters
    Catho, G.
    Mangeret, F. Rosa
    Sauvan, V.
    Chraiti, M. -N.
    Pfister, R.
    Baud, O.
    Harbarth, S.
    Buetti, N.
    [J]. JOURNAL OF HOSPITAL INFECTION, 2023, 139 : 6 - 10
  • [6] Risk Factors for Catheter-associated Bloodstream Infections in a Pediatric Cardiac Intensive Care Unit
    Prasad, Priya A.
    Dominguez, Troy E.
    Zaoutis, Theoklis E.
    Shah, Samir S.
    Teszner, Eva
    Gaynor, J. William
    Tabbutt, Sarah
    Coffin, Susan E.
    [J]. PEDIATRIC INFECTIOUS DISEASE JOURNAL, 2010, 29 (09) : 812 - 815
  • [7] An Evidence-Based Approach for Managing Catheter-Associated Bloodstream Infection in a Level II Neonatal Intensive Care Unit
    Joy-Joseph, Lovely
    Colin, Jessie M.
    Rosenstein, Cindy Rich
    Chinye-Onyejuruwa, Francesca
    [J]. JOURNAL OF NURSING CARE QUALITY, 2010, 25 (02) : 100 - 104
  • [8] The effect of an education program on the incidence of catheter-associated bloodstream infection in a medical intensive care unit
    Zack, JE
    Osmon, S
    Chen, A
    Prentice, D
    Fraser, VJ
    Kollef, MH
    [J]. CHEST, 2004, 126 (04) : 746S - 746S
  • [9] Using Evidence to Decrease the Central Catheter-Associated Bloodstream Infection Rate in the Intensive Care Unit
    Baran, Monica
    Murray, Caitlin
    Burk, Lauren
    [J]. CRITICAL CARE NURSE, 2019, 39 (02) : E43 - E44
  • [10] Preventive bundles to reduce catheter-associated bloodstream infections in neonatal intensive care
    Schmid, Sarah
    Geffers, Christine
    Wagenpfeil, Gudrun
    Simon, Arne
    [J]. GMS HYGIENE AND INFECTION CONTROL, 2018, 13