Fenton and photo-Fenton processes integrated with submerged ultrafiltration for the treatment of pulp and paper industry wastewater

被引:16
|
作者
Dogan, Esra Can [1 ]
Kilicoglu, Odul [1 ,2 ]
Narci, Ali Oguzhan [1 ,3 ]
Mert, Berna Kiril [4 ]
Durna, Elif [1 ]
Akbacak, Umur Alkan [1 ]
Aydiner, Coskun [5 ]
机构
[1] Kocaeli Univ, Dept Environm Engn, TR-41001 Kocaeli, Turkey
[2] Arbiogaz Environm Technol Construct Ind, TR-34398 Istanbul, Turkey
[3] Mugla Water & Sewerage Adm, Mugla Metropolitan Municipal, Drinking Water Dept, TR-48000 Mentese, Mugla, Turkey
[4] Sakarya Univ, Dept Environm Engn, TR-54050 Serdivan, Sakarya, Turkey
[5] Gebze Tech Univ, Dept Environm Engn, TR-41400 Kocaeli, Turkey
来源
关键词
Pulp and paper wastewater; Membrane oxidation reactor; (Photo)-Fenton enhanced ultrafiltration; Taguchi experimental design; Response surface optimisation; Operating cost; ADVANCED OXIDATION PROCESSES; MEMBRANE SEPARATION; OPERATING-CONDITIONS; LANDFILL LEACHATE; REVERSE-OSMOSIS; FLUX RECOVERY; MILL EFFLUENT; OPTIMIZATION; DEGRADATION; PERFORMANCE;
D O I
10.1016/j.jece.2021.105878
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Excessive amounts of wastewater produced by the paper industry, often containing a wide range of toxic and recalcitrant pollutants based on raw materials used, should be subjected to efficient treatment processes before discharging to the environment. This experimental work examined hybrid Fenton and photo-Fenton enhanced (UVC254 and UVA(365)) UF system performances in treating raw wastewater from pulp and paper industry by membrane oxidation reactor (MOR). By response surface analyses of Taguchi experimental design, the systems were compared onto hybrid efficiencies, in settings optimized for maximal responses with minimum chemical needs, regarding the performance metrics of TOC and COD removal efficiencies and UF water flux. Organics were removed slightly better than Fenton in both photo-Fenton, and H2O2 and Fe2+ spends per TOC were accomplished as more efficient than anticipated in every MOR system. Optimal TOC-COD removals were found as 64.0-74.9% by 85.2 L/m(2)h at Fenton system, and as 66.5-76.1% by 138.1 L/m(2)h at UVA-Fenton, while 69.7-82.1% by 90.0 L/m(2)h at UVC-Fenton with the lowest chemical spending. Hybrid MORs studied were at desirable operational costs of 2.11, 4.15 and 3.13 $/kg removed COD in Fenton, UVA-Fenton and UVC-Fenton systems, respectively, corresponding to the demineralisation costs of 0.0075-0.0143 $/g TOC removed. This study revealed that by synergistic MOR performances, effluents, after pH adjustment, are directly dischargeable in sewage infrastructure ending with complete treatment. In a near future, such innovative approaches towards industrial wastewater treatments, at less resource demands, will unambiguously gain importance, as pressures to reuse wastewater increase and discharge limits become stricter.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Chemical industry wastewater treatment by coagulation combined with Fenton and photo-Fenton processes
    Metin, Seda
    Cifci, Deniz Izlen
    [J]. JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2023, 98 (05) : 1158 - 1165
  • [2] Treatment of pulp and paper mill wastewater by solar photo-Fenton process
    Ginni, G.
    Adishkumar, S.
    Banu, J. Rajesh
    Yogalakshmi, N.
    [J]. DESALINATION AND WATER TREATMENT, 2014, 52 (13-15) : 2457 - 2464
  • [3] Comparison of Fenton and Photo-Fenton processes for livestock wastewater treatment
    Park, JH
    Cho, IH
    Chang, SW
    [J]. JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART B-PESTICIDES FOOD CONTAMINANTS AND AGRICULTURAL WASTES, 2006, 41 (02) : 109 - 120
  • [4] Synergies of metallic catalysts in the Fenton and photo-Fenton processes applied to the treatment of pulp bleaching wastewater
    Ribeiro, Joao Peres
    Gomes, Helena G. M. F.
    Sarinho, Luana
    Marques, Catarina C.
    Nunes, Maria Isabel
    [J]. CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2022, 181
  • [5] AOX removal from pulp and paper wastewater by Fenton and photo-Fenton processes: A real case-study
    Ribeiro, J. P.
    Marques, C. C.
    Portugal, I
    Nunes, M., I
    [J]. ENERGY REPORTS, 2020, 6 : 770 - 775
  • [6] Comparison of kinetics and costs of Fenton and photo-Fenton processes used for the treatment of a textile industry wastewater
    Calik, Cagla
    Cifci, Deniz Izlen
    [J]. JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2022, 304
  • [7] Tertiary treatment of pulp mill wastewater by solar photo-Fenton
    Lucas, Marco S.
    Peres, Jose A.
    Amor, Carlos
    Prieto-Rodriguez, Lucia
    Maldonado, Manuel I.
    Malato, Sixto
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2012, 225 : 173 - 181
  • [8] Treatment of wastepaper pulp wastewater by heterogeneous photo-Fenton process
    College of Mechanical and Energy Engineering, Ningbo Institute of Technology, Zhejiang University, Ningbo 315100, China
    不详
    [J]. Harbin Gongye Daxue Xuebao, 2009, 8 (142-148):
  • [9] TREATMENT OF WASTEWATER FROM CAR WASH BY FENTON AND PHOTO-FENTON OXIDATIVE PROCESSES
    Magnago, Rachel F.
    Berselli, Diego
    Medeiros, Patricia
    [J]. JOURNAL OF ENGINEERING SCIENCE AND TECHNOLOGY, 2018, 13 (04) : 838 - 850
  • [10] Removal of organic contaminants in paper pulp treatment effluents under Fenton and photo-Fenton conditions
    Pérez, M
    Torrades, F
    García-Hortal, JA
    Domènech, X
    Peral, J
    [J]. APPLIED CATALYSIS B-ENVIRONMENTAL, 2002, 36 (01) : 63 - 74