Glucose biosensing at carbon paste electrodes containing iron nanoparticles

被引:21
|
作者
Comba, Fausto N. [1 ]
Rubianes, Maria D. [1 ]
Herrasti, Pilar [2 ]
Rivas, Gustavo A. [1 ]
机构
[1] Univ Nacl Cordoba, Fac Ciencias Quim, Dept Quim Fis, INFIQC, RA-5000 Cordoba, Argentina
[2] Univ Autonoma Madrid, Fac Ciencias, Dept Quim Fis Aplicada, SSIC, E-28049 Madrid, Spain
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2010年 / 149卷 / 01期
关键词
Iron; Nanoparticles; Carbon paste electrode; Hydrogen peroxide; Glucose oxidase; Amperometric glucose biosensor; HYDROGEN-PEROXIDE; OXIDASE; IMMOBILIZATION; SENSORS; OXIDES; COPPER;
D O I
10.1016/j.snb.2010.06.020
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work reports the advantages of incorporating a metal as common as iron in a carbon paste electrode containing glucose oxidase to develop highly selective, stable and sensitive amperometric glucose biosensors. The excellent catalytic activity of iron nanoparticles towards the reduction of hydrogen peroxide has made possible the quantification of glucose at very low potentials (-0.100V) avoiding, in this way, the interference of easily oxidizable compounds like ascorbic acid and uric acid without needing of redox mediators or permselective membranes. Linear relationship between current and glucose concentration was obtained up to 0.020M (3.6 g/L), with a detection limit of 0.2 mM, no interference of AA and UA, and very good correlation with the spectrophotometric methods when determining glucose in human blood serum. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:306 / 309
页数:4
相关论文
共 50 条
  • [1] Glucose Biosensing at Carbon Paste Electrodes Containing Polyaniline-Silicon dioxide Composite
    Arslan, Halit
    Ozdemir, Merve
    Zengin, Huseyin
    Zengin, Gulay
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (10): : 10205 - 10214
  • [2] Highly Sensitive and Selective Glucose Biosensing at Carbon Paste Electrodes Modified with Electrogenerated Magnetite Nanoparticles and Glucose Oxidase
    Comba, Fausto N.
    Rubianes, Maria D.
    Cabrera, Lourdes
    Gutierrez, Silvia
    Herrasti, Pilar
    Rivas, Gustavo A.
    ELECTROANALYSIS, 2010, 22 (14) : 1566 - 1572
  • [3] Metal-alloy-dispersed carbon-paste enzyme electrodes for amperometric biosensing of glucose
    Liu, J
    Lu, F
    Wang, J
    ELECTROCHEMISTRY COMMUNICATIONS, 1999, 1 (08) : 341 - 344
  • [4] METALLOPORPHYRIN CONTAINING CARBON PASTE ELECTRODES
    TAKEUCHI, ES
    MURRAY, RW
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 188 (1-2): : 49 - 57
  • [5] Ordered mesoporous carbon paste electrodes for electrochemical sensing and biosensing
    Zhu, Liande
    Tian, Chunyuan
    Zhu, Dongxia
    Yang, Ruilan
    ELECTROANALYSIS, 2008, 20 (10) : 1128 - 1134
  • [6] Aggregates of gold nanoparticles with complexes containing ruthenium as modifiers in carbon paste electrodes
    de Oliveira, Katia M.
    dos Santos, Thais C. C.
    Dinelli, Luis R.
    Marinho, Juliane Z.
    Lima, Renata C.
    Bogado, Andre L.
    POLYHEDRON, 2013, 50 (01) : 410 - 417
  • [7] METALLOPORPHYRIN CONTAINING CARBON PASTE ELECTRODES.
    Takeuchi, Esther S.
    Murray, Royce W.
    Journal of electroanalytical chemistry and interfacial electrochemistry, 1985, 188 (1-2): : 49 - 57
  • [8] HIGHLY SELECTIVE AND SENSITIVE AMPEROMETRIC BIOSENSING OF GLUCOSE AT RUTHENIUM-DISPERSED CARBON-PASTE ENZYME ELECTRODES
    WANG, J
    FANG, L
    LOPEZ, D
    TOBIAS, H
    ANALYTICAL LETTERS, 1993, 26 (09) : 1819 - 1830
  • [9] HIGHLY SELECTIVE BIOSENSING OF LACTATE AT LACTATE OXIDASE CONTAINING RHODIUM-DISPERSED CARBON-PASTE ELECTRODES
    WANG, J
    CHEN, Q
    PEDRERO, M
    ANALYTICA CHIMICA ACTA, 1995, 304 (01) : 41 - 46
  • [10] Electrochemistry of reconstituted glucose oxidase on carbon paste electrodes
    Savitri, D
    Mitra, CK
    BIOELECTROCHEMISTRY AND BIOENERGETICS, 1998, 47 (01): : 67 - 73