Improved STATCOM operation under transient disturbances for wind power applications

被引:0
|
作者
Etxeberria-Otadui, Ion [1 ]
Viscarret, Unai [1 ]
Zamakona, Izaskun [2 ]
Redondo, Beatriz Arenal [3 ]
Ibiricu, Javier [4 ]
机构
[1] IKERLAN IK4 Technol Res Ctr, Apdo 146, E-20500 Arrasate Mondragon, Spain
[2] OLDAR Elect SA, E-48140 Igorre, Spain
[3] JEMA, E-20160 Lasarte Oria, Spain
[4] Eol Euskadi, Minano 01510, Spain
关键词
STATCOM; converter control; wind energy;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents an optimized STATCOM control for wind power applications. The transient behavior of fixed-speed wind farms can be improved by injecting large amounts of reactive power during the fault recovery. This application requires a high dynamic converter, which must also be capable of working under transient unbalanced conditions. Here, a stationary control structure is proposed, which is based on resonant regulators and a DFT synchronization algorithm, which allows an optimized reactive power injection during voltage dips occurred in the grid. The proposed structure is validated experimentally using a reduced scale STATCOM prototype, showing that it is well adapted for the concerned application.
引用
收藏
页码:2450 / +
页数:2
相关论文
共 50 条
  • [1] STATCOM operation strategy under power system faults
    Xi, Zhengping
    Bhattacharya, Subhashish
    2007 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-10, 2007, : 4308 - +
  • [2] Stabilization of gird connected wind generator during power network disturbances by STATCOM
    Jazayeri, M.
    Fendereski, M.
    2007 42ND INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1-3, 2007, : 1182 - 1186
  • [3] Application of STATCOM for Improved Reliability of Power Grid Containing a Wind Turbine
    Jayam, Aditya P.
    Ardeshna, Nikhil K.
    Chowdhury, Badrul H.
    2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 4043 - 4049
  • [4] STATCOM size optimization through wind turbine operation with fixed power factor
    Maibach, Philippe
    Ritter, Carsten
    Saleh, Mohamed
    Thurnherr, Tobias
    PROCEEDINGS OF THE 2011-14TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE 2011), 2011,
  • [5] Operation of wind energy installations during power network disturbances
    Ullah, Nayeem Rahmat
    Thiringer, Torbjoern
    Karlsson, Daniel
    IEEE IEMDC 2007: PROCEEDINGS OF THE INTERNATIONAL ELECTRIC MACHINES AND DRIVES CONFERENCE, VOLS 1 AND 2, 2007, : 1396 - +
  • [6] Extraction of Extreme Operation Scenarios in Power Grid for Transient Angle Stability Analysis Under Wind Power Integration
    面向风电接入暂态功角稳定分析的电网极端运行场景提取
    1600, Automation of Electric Power Systems Press (45): : 113 - 120
  • [7] Transient disturbances location based on improved disturbance power and energy
    Zhang, Wentao
    Wang, Chengshan
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2007, 31 (08): : 32 - 35
  • [8] Steady state and transient operation analysis of wind power systems
    Litifu, Z
    Nagasaka, K
    Chu, CHK
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2005, 27 (04) : 284 - 292
  • [9] Control of Hydraulic Wind Power Transfer System Under Wind and Load Disturbances
    Vaezi, Masoud
    Asgharifard, Aryan
    Izadian, Afshin
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2018, 54 (04) : 3596 - 3603
  • [10] Implementation of STATCOM to overcome disturbances in grid connected Wind farm
    Roy, Chitrangada
    Sengupta, Anirban
    2015 INTERNATIONAL CONFERENCE ON ENERGY, POWER AND ENVIRONMENT: TOWARDS SUSTAINABLE GROWTH (ICEPE), 2015,