VALIDITY AND RELIABILITY OF OPTOJUMP PHOTOELECTRIC CELLS FOR ESTIMATING VERTICAL JUMP HEIGHT

被引:407
|
作者
Glatthorn, Julia F. [1 ]
Gouge, Sylvain [2 ]
Nussbaumer, Silvio [1 ]
Stauffacher, Simone [1 ]
Impellizzeri, Franco M. [1 ]
Maffiuletti, Nicola A. [1 ]
机构
[1] Schulthess Clin, Neuromuscular Res Lab, Zurich, Switzerland
[2] Univ Burgundy, Fac Sport Sci, Dijon, France
关键词
squat jump; countermovement jump; intraclass correlation coefficient; force plate; STATISTICAL-METHODS; POWER; PERFORMANCE;
D O I
10.1519/JSC.0b013e3181ccb18d
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Glatthorn, JF, Gouge, S, Nussbaumer, S, Stauffacher, S, Impellizzeri, FM, and Maffiuletti, NA. Validity and reliability of Optojump photoelectric cells for estimating vertical jump height. J Strength Cond Res 25(2): 556-560, 2011-Vertical jump is one of the most prevalent acts performed in several sport activities. It is therefore important to ensure that the measurements of vertical jump height made as a part of research or athlete support work have adequate validity and reliability. The aim of this study was to evaluate concurrent validity and reliability of the Optojump photocell system (Microgate, Bolzano, Italy) with force plate measurements for estimating vertical jump height. Twenty subjects were asked to perform maximal squat jumps and countermovement jumps, and flight time-derived jump heights obtained by the force plate were compared with those provided by Optojump, to examine its concurrent (criterion-related) validity (study 1). Twenty other subjects completed the same jump series on 2 different occasions (separated by 1 week), and jump heights of session 1 were compared with session 2, to investigate test-retest reliability of the Optojump system (study 2). Intraclass correlation coefficients (ICCs) for validity were very high (0.997-0.998), even if a systematic difference was consistently observed between force plate and Optojump (-1.06 cm; p < 0.001). Test-retest reliability of the Optojump system was excellent, with ICCs ranging from 0.982 to 0.989, low coefficients of variation (2.7%), and low random errors (+/- 2.81 cm). The Optojump photocell system demonstrated strong concurrent validity and excellent test-retest reliability for the estimation of vertical jump height. We propose the following equation that allows force plate and Optojump results to be used interchangeably: force plate jump height (cm) = 1.02 x Optojump jump height + 0.29. In conclusion, the use of Optojump photoelectric cells is legitimate for field-based assessments of vertical jump height.
引用
下载
收藏
页码:556 / 560
页数:5
相关论文
共 50 条
  • [1] The Reliability and Validity of the Fitjump Photoelectric Cell System for Determining Vertical Jump Height
    Yildiz, Mehmet
    Fidan, Ugur
    MEASUREMENT IN PHYSICAL EDUCATION AND EXERCISE SCIENCE, 2020, 24 (01) : 56 - 64
  • [2] Concurrent validity and reliability of photoelectric and accelerometer technology for calculating vertical jump height in female athletes
    Perrotta, Andrew S.
    Day, Brent D.
    Wafai, Ibrahim
    Oates, Robert P.
    Peterson, Maggie L.
    Scott, Anika J.
    Barker, Rachel C.
    Garedakis, Athena B.
    Seaborn, Kayla A.
    SPORTS ENGINEERING, 2023, 26 (01)
  • [3] Reliability and Validity of the Polar V800 Sports Watch for Estimating Vertical Jump Height
    Garnacho-Castano, Manuel, V
    Faundez-Zanuy, Marcos
    Serra-Paya, Noemi
    Mate-Munoz, Jose L.
    Lopez-Xarbau, Josep
    Vila-Blanch, Moises
    JOURNAL OF SPORTS SCIENCE AND MEDICINE, 2021, 20 (01) : 149 - 157
  • [4] VALIDITY AND RELIABILITY OF THE MYOTEST ACCELEROMETRIC SYSTEM FOR THE ASSESSMENT OF VERTICAL JUMP HEIGHT
    Casartelli, Nicola
    Mueller, Roland
    Maffiuletti, Nicola A.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2010, 24 (11) : 3186 - 3193
  • [5] Measurement errors when estimating the vertical jump height with flight time using photocell devices: the example of Optojump
    Attia, A.
    Dhahbi, W.
    Chaouachi, A.
    Padulo, J.
    wong, D. P.
    Chamari, K.
    BIOLOGY OF SPORT, 2017, 34 (01) : 63 - 70
  • [6] Validity of a Vertical Jump Mat for Determining Vertical Jump Height
    Forsythe, Charles M.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 : 517 - 518
  • [7] Concurrent Validity and Reliability of My Jump 2 App for Measuring Vertical Jump Height in Recreationally Active Adults
    Bogataj, Spela
    Pajek, Maja
    Andrasic, Slobodan
    Trajkovic, Nebojsa
    APPLIED SCIENCES-BASEL, 2020, 10 (11):
  • [8] Evidence of validity and reliability of Jumpo 2 and MyJump 2 for estimating vertical jump variables
    Vieira, Amilton
    Ribeiro, Gabriela L.
    Macedo, Victor
    Rocha Junior, Valdinar de Araujo
    Baptista, Roberto de Souza
    Goncalves, Carlos
    Cunha, Rafael
    Tufano, James
    PEERJ, 2023, 11
  • [9] Validity and reliability of a new portable and cost-effective photoelectric cells device for measuring vertical jump performance: "The ADR Jumping"
    Rodrigo-Carranza, Victor
    Lopez-Torres, Olga
    Fernandez-Elias, Valentin E.
    Gomez-Ruano, Miguel-Angel
    Guadalupe-Grau, Amelia
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART P-JOURNAL OF SPORTS ENGINEERING AND TECHNOLOGY, 2023,
  • [10] Validity of My Jump App to Measure Vertical Jump Height of the Elderly
    Oliveira-Silva, Iranse
    Cruvinel-Cabral, Rejane M.
    Medeiros, Andre R.
    Boullosa, Daniel A.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2018, 50 (05): : 615 - 615