Emission Characteristics of Laser-Induced Plasma Using Collinear Long and Short Dual-Pulse Laser-Induced Breakdown Spectroscopy (LIBS)

被引:29
|
作者
Wang, Zhenzhen [1 ,2 ]
Deguchi, Yoshihiro [2 ]
Liu, Renwei [2 ,3 ]
Ikutomo, Akihiro [2 ]
Zhang, Zhenzhen [3 ]
Chong, Daotong [1 ]
Yan, Junjie [1 ]
Liu, Jiping [3 ]
Shiou, Fang-Jung [4 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Multiphase Flow Power Engn, Xian, Shaanxi, Peoples R China
[2] Tokushima Univ, Grad Sch Adv Technol & Sci, 2-1 Minamijyosanjima, Tokushima 7708506, Japan
[3] Xi An Jiao Tong Univ, Moe Key Lab Thermofluid Sci & Engn, Xian, Shaanxi, Peoples R China
[4] Natl Taiwan Univ Sci & Technol, Dept Mech Engn, Taipei, Taiwan
基金
中国国家自然科学基金;
关键词
Long pulse; dual-pulse laser-induced breakdown spectroscopy; DP-LIBS; enhancement; plasma temperature stabilization; underwater measurement; AMBIENT GAS; ABLATION; ENHANCEMENT; FEASIBILITY; PRESSURES; MAGNESIUM; SPECTRUM; LIQUIDS; SAMPLES;
D O I
10.1177/0003702817693239
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Collinear long and short dual-pulse laser-induced breakdown spectroscopy (DP-LIBS) was employed to clarify the emission characteristics from laser-induced plasma. The plasma was sustained and became stable by the long pulse-width laser with the pulse width of 60s under free running (FR) conditions as an external energy source. Comparing the measurement results of stainless steel in air using single-pulse LIBS (SP-LIBS) and DP-LIBS, the emission intensity was markedly enhanced using DP-LIBS. The temperature of plasma induced by DP-LIBS was maintained at a higher temperature under different gate delay time and short pulse-width laser power conditions compared with those measured using short SP-LIBS. Moreover, the variation rates of plasma temperatures measured using DP-LIBS were also lower. The superior detection ability was verified by the measurement of aluminum sample in water. The spectra were clearly detected using DP-LIBS, whereas it cannot be identified using SP-LIBS of short and long pulse widths. The effects of gate delay time and short pulse-width laser power were also discussed. These results demonstrate the feasibility and enhanced detection ability of the proposed collinear long and short DP-LIBS method.
引用
收藏
页码:2187 / 2198
页数:12
相关论文
共 50 条
  • [1] Plasma dynamics and chlorine emission characteristics on cement pastes using collinear dual-pulse laser-induced breakdown spectroscopy
    Qiu, Yan
    Guo, Xinyu
    Shi, Mingxin
    Zhou, Ying
    Wu, Jian
    Li, Jinghui
    Sun, Hao
    Zhang, Zhi
    Hang, Yuhua
    Li, Xingwen
    Li, Yongdong
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2023, 209
  • [2] Nanosecond laser preheating effect on ablation morphology and plasma emission in collinear dual-pulse laser-induced breakdown spectroscopy
    Li, Na
    Harefa, Edward
    Zhou, Weidong
    [J]. PLASMA SCIENCE & TECHNOLOGY, 2022, 24 (11)
  • [3] Nanosecond laser preheating effect on ablation morphology and plasma emission in collinear dual-pulse laser-induced breakdown spectroscopy
    李娜
    Edward HAREFA
    周卫东
    [J]. Plasma Science and Technology, 2022, (11) : 163 - 168
  • [4] Nanosecond laser preheating effect on ablation morphology and plasma emission in collinear dual-pulse laser-induced breakdown spectroscopy
    李娜
    Edward HAREFA
    周卫东
    [J]. Plasma Science and Technology, 2022, 24 (11) : 163 - 168
  • [5] Emission enhancement of underwater collinear dual-pulse laser-induced breakdown spectroscopy with the second pulse defocused
    Xue, Boyang
    Li, Nan
    Lu, Yuan
    Li, Yuandong
    Zheng, Ronger
    [J]. APPLIED PHYSICS LETTERS, 2017, 110 (10)
  • [6] Observations in collinear femtosecond-nanosecond dual-pulse laser-induced breakdown spectroscopy
    Scaffidi, J
    Pearman, W
    Carter, JC
    Angel, SM
    [J]. APPLIED SPECTROSCOPY, 2006, 60 (01) : 65 - 71
  • [7] On the Optimization for Enhanced Dual-Pulse Laser-Induced Breakdown Spectroscopy
    Ahmed, Rizwan
    Baig, M. A.
    [J]. IEEE TRANSACTIONS ON PLASMA SCIENCE, 2010, 38 (08) : 2052 - 2055
  • [8] Direct Measurements of Sample Heating by a Laser-Induced Air Plasma in Pre-Ablation Spark Dual-Pulse Laser-Induced Breakdown Spectroscopy (LIBS)
    Register, Janna
    Scaffidi, Jonathan
    Angel, S. Michael
    [J]. APPLIED SPECTROSCOPY, 2012, 66 (08) : 869 - 874
  • [9] Laser-induced plasma and laser-induced breakdown spectroscopy (LIBS) in China: The challenge and the opportunity
    Jin Yu
    Ronger Zheng
    [J]. Frontiers of Physics, 2012, 7 : 647 - 648
  • [10] Laser-induced plasma and laser-induced breakdown spectroscopy (LIBS) in China: The challenge and the opportunity
    Yu, Jin
    Zheng, Ronger
    [J]. FRONTIERS OF PHYSICS, 2012, 7 (06) : 647 - 648