Usefulness of microvolt T-wave alternans on predicting outcome in patients with ischemic cardiomyopathy with and without defibrillators

被引:18
|
作者
Chow, Theodore [1 ]
Saghir, Sayed
Bartone, Cheryl
Goebel, Megan
Schneider, Julia
Booth, Terri
Chan, Paul S.
机构
[1] Christ Hosp, Linder Clin Trial Ctr, Cincinnati, OH 45219 USA
[2] Ohio Heart & Vasc Ctr, Cincinnati, OH 45219 USA
[3] VA Hlth Serv Res & Dev, Ann Arbor, MI USA
[4] Univ Michigan, Sch Med, Ann Arbor, MI USA
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2007年 / 100卷 / 04期
基金
美国国家卫生研究院;
关键词
D O I
10.1016/j.amjcard.2007.03.069
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Microvolt T-wave alternans (MTWA) was proposed as an effective tool to identify high-risk patients with ischemic cardiomyopathy. However, previous studies suggested that the prognostic utility of MTWA may be limited to only patients with normal QRS duration. It therefore was assessed whether MTWA and QRS duration > 120 ms independently predict mortality in patients with ischemic cardiomyopathy and whether the prognostic utility of MTWA differs by QRS duration. A total of 768 consecutive patients with ischernic cardiomyopathy (left ventricular ejection fraction <= 35%) and no history of ventricular arrhythmia were enrolled, of whom 514 (67%) screened MTWA non-negative (positive or indeterminate) and 223 (29%) had a QRS > 120 ms on resting electrocardiogram. After multivariable adjustment, a non-negative MTWA test result was associated with a significantly higher risk for all-cause mortality in patients without an implantable cardioverter-defibrillator (ICD) (hazard ratio [HR] 2.27, 95% confidence interval [CI] 1.22 to 4.24, p = 0.01) and for all-cause mortality and appropriate ICD shocks in patients with an ICD (HR 2.42,95% CI 1.07 to 5.41, p = 0.04). In contrast, a QRS > 120 ins was not associated with all-cause mortality and ICD shocks in patients without (HR 0.96, 95% CI 0.52 to 1.75, p = 0.88) or with an ICD (HR 1.25, 95% CI 0.76 to 2.08, p = 0.40). No significant interaction was found between MTWA and QRS > 120 ms (non-ICD p = 0. 19, ICD p = 0.73). In conclusion, MTWA, but not QRS duration, predicted mortality outcomes in patients with ischemic cardiomyopathy. Moreover, the prognostic utility of MTWA did not appear to differ by QRS duration. (c) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:598 / 604
页数:7
相关论文
共 50 条
  • [1] Usefulness of microvolt T-wave alternans for predicting outcome in patients with Chagas disease with implantable cardioverter defibrillators
    Tomaz Barbosa, Marco Paulo
    da Costa Rocha, Manoel Otavio
    Santos Neto, Elson
    Brandao, Fernando Vieira
    Lombardi, Federico
    Pinho Ribeiro, Antonio Luiz
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 222 : 80 - 85
  • [2] Microvolt T-wave alternans in ischemic cardiomyopathy
    Madias, John E.
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 162 (02) : 135 - 136
  • [3] Microvolt T-wave alternans predicts mortality in patients with ischemic cardiomyopathy
    [J]. Nature Clinical Practice Cardiovascular Medicine, 2006, 3 (8): : 406 - 407
  • [4] The Usefulness of Microvolt T-Wave Alternans in the Risk Stratification of Patients with Hypertrophic Cardiomyopathy
    Fuchs, Therese
    Torjman, Amram
    [J]. ISRAEL MEDICAL ASSOCIATION JOURNAL, 2009, 11 (10): : 606 - 610
  • [5] Usefulness of microvolt T-Wave alternans to predict outcomes in patients with ischemic cardiomyopathy beyond one year
    Chan, Paul S.
    Kereiakes, Dean J.
    Bartone, Cheryl
    Chow, Theodore
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (03): : 280 - 284
  • [6] Can microvolt T-wave alternans predict mortality in patients with ischemic cardiomyopathy?
    Hohnloser, Stefan H.
    [J]. NATURE CLINICAL PRACTICE CARDIOVASCULAR MEDICINE, 2006, 3 (09): : 470 - 471
  • [7] Microvolt T-wave alternans identifies ICD benefit in ischemic cardiomyopathy patients
    Chan, Paul S.
    Kereiakes, Dean J.
    Bartone, Cheryl
    Booth, Terri
    Schloss, Edward J.
    Waller, Theodore
    Chung, Eugene
    Menon, Samosh
    Nallamothu, Brahmajee K.
    Chow, Theodore
    [J]. CIRCULATION, 2006, 114 (18) : 406 - 406
  • [8] Can microvolt T-wave alternans predict mortality in patients with ischemic cardiomyopathy?
    Stefan H Hohnloser
    [J]. Nature Clinical Practice Cardiovascular Medicine, 2006, 3 : 470 - 471
  • [9] Prognostic utility of microvolt T-wave alternans in risk stratification of patients with ischemic cardiomyopathy
    Chow, T
    Kereiakes, DJ
    Bartone, C
    Booth, T
    Schloss, EJ
    Waller, T
    Chung, ES
    Menon, S
    Nallamothu, BK
    Chan, PS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (09) : 1820 - 1827
  • [10] Detection and Analysis of Microvolt T-wave Alternans in Patients with Cardiomyopathy
    Wang, X. X.
    Huang, Z. C.
    [J]. CARDIOLOGY, 2010, 117 : 75 - 75