Bacteria detection using disposable optical leaky waveguide sensors

被引:54
|
作者
Zourob, M
Mohr, S
Brown, BJT
Fielden, PR
McDonnell, MB
Goddard, NJ
机构
[1] Univ Manchester, Sch Chem Engn & Analyt Sci, Manchester M60 1QD, Lancs, England
[2] Dstl Porton Down, Salisbury SP4 0JQ, Wilts, England
来源
BIOSENSORS & BIOELECTRONICS | 2005年 / 21卷 / 02期
关键词
optical waveguide; evanescent wave sensor; leaky waveguide; bacteria detection; biosensor; disposable sensor;
D O I
10.1016/j.bios.2004.10.013
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Novel disposable absorbing material clad leaky waveguide sensor devices (LWD) have been developed for the detection of pathogenic particles such as bacteria. These chips are tailored to give the maximum extension of the evanescent field at the sensor surface in order to place the entire Volume of the bacteria captured by immobilized antibodies on the chip surface within this field. This in turn increases the interaction of the light with the bacteria's bulk volume. Disposable LWD chips were fabricated at room temperature and without the use of expensive fabrication equipment. These LWDs have been characterised by detecting refractive index (RI) changes, scattering and fluorescence from bacterial spores at the sensor surface when illuminated at the coupling angle. The detection limit of Bacillus subtilis var. niger (BG) bacterial spores was 10(4) spores/ml and the illumination intensity of the spores was found to be three times greater than the illumination intensity generated using the surface plasmon resonance (SPR). (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:293 / 302
页数:10
相关论文
共 50 条
  • [1] Optical leaky waveguide sensor for detection of bacteria with ultrasound attractor force
    Zourob, M
    Hawkes, JJ
    Coakley, WT
    Brown, BJT
    Fielden, PR
    McDonnell, MB
    Goddard, NJ
    ANALYTICAL CHEMISTRY, 2005, 77 (19) : 6163 - 6168
  • [2] An integrated optical leaky waveguide sensor with electrically induced concentration system for the detection of bacteria
    Zourob, M
    Mohr, S
    Brown, BJT
    Fielden, PR
    McDonnell, MB
    Goddard, NJ
    LAB ON A CHIP, 2005, 5 (12) : 1360 - 1365
  • [3] An integrated metal clad leaky waveguide sensor for detection of bacteria
    Zourob, M
    Mohr, S
    Brown, BJT
    Fielden, PR
    McDonnell, MB
    Goddard, NJ
    ANALYTICAL CHEMISTRY, 2005, 77 (01) : 232 - 242
  • [4] Optical leaky waveguide biosensors for the detection of organophosphorus pesticides
    Zourob, M.
    Simonian, A.
    Wild, J.
    Mohr, S.
    Fan, Xudong
    Abdulhalim, I.
    Goddard, N. J.
    ANALYST, 2007, 132 (02) : 114 - 120
  • [5] Optical Leaky Waveguide Antenna Using Shallow Etched Circular Waffled Waveguide
    Hashiguchi, Hiroshi
    Baba, Toshihiko
    Arai, Hiroyuki
    2017 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION & USNC/URSI NATIONAL RADIO SCIENCE MEETING, 2017, : 1275 - 1276
  • [6] DEVELOPMENT AND EVALUATION OF OPTICAL SENSORS FOR THE DETECTION OF BACTERIA
    SWENSON, FJ
    SENSORS AND ACTUATORS B-CHEMICAL, 1993, 11 (1-3) : 315 - 321
  • [7] An integrated disposable dye clad leaky waveguide sensor for μ-TAS applications
    Zourob, M
    Mohr, S
    Fielden, PR
    Goddard, NJ
    LAB ON A CHIP, 2005, 5 (07): : 772 - 777
  • [8] Sensitive and selective cocaine electrochemical detection using disposable sensors
    Asturias-Arribas, Laura
    Asuncion Alonso-Lomillo, M.
    Dominguez-Renedo, Olga
    Julia Arcos-Martinez, M.
    ANALYTICA CHIMICA ACTA, 2014, 834 : 30 - 36
  • [9] Detection of heavy metals using disposable modified electrochemical sensors
    Laschi, S
    Palchetti, I
    Mascini, M
    SENSORS AND MICROSYSTEMS, PROCEEDINGS, 2004, : 275 - 279
  • [10] Fabrication of disposable sensors for biomolecule detection using hydrazine electrocatalyst
    Shiddiky, Muhammad J. A.
    Rahman, Md. Aminur
    Cheol, Chang Seung
    Shim, Yoon-Bo
    ANALYTICAL BIOCHEMISTRY, 2008, 379 (02) : 170 - 175