Breakdown Characteristics of Rod-Plane Gap in an Ethanol Flame

被引:1
|
作者
Wang, Zhenhua [1 ,2 ]
Shui, Kai [1 ,2 ]
Huangfu, Wenhao [3 ]
Zhao, Yaopeng [1 ,2 ]
Chen, Siyi [1 ,2 ]
You, Fei [1 ,2 ]
Zhang, Yun [4 ]
Jiang, Juncheng [1 ,5 ]
机构
[1] Nanjing Tech Univ, Coll Safety Sci & Engn, Nanjing 211816, Jiangsu, Peoples R China
[2] Nanjing Tech Univ, Inst Fire Sci & Engn, Nanjing 211816, Jiangsu, Peoples R China
[3] Sinochem Environm Protect Chem Taicang Co Ltd, Taicang 215433, Jiangsu, Peoples R China
[4] China Southern Power Grid Extra High Voltage Powe, Wuzhou Branch, Wuzhou 543002, Guangxi, Peoples R China
[5] Changzhou Univ, Sch Environm & Safety Engn, Changzhou 213164, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Fires; Power transmission lines; Ethanol; Electric breakdown; Electrodes; Discharges (electric); Flashover; Average breakdown strength; breakdown voltage; ethanol diffusion flame; high-voltage transmission line; ionic wind effect; leakage current; rod-plane electrode; wildfire; TRANSMISSION-LINE;
D O I
10.1109/TDEI.2022.3146541
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The wildfires nearby high-voltage transmission lines are frequently reported to induce outages in many countries. Less research addresses the role played by individual characteristic factor (i.e., high temperature, intense heat, etc.) of wildfires in triggering phase-to-ground flashovers of transmission lines. Aiming at this, systematic laboratory experiments are performed to reveal the breakdown characteristics of rod-(ring-like) plane gap in clean ethanol flames. By setting different scenarios of pure air gap, nonbridged and bridged gaps by ethanol flames, the breakdown voltage, average breakdown strength, and leakage current with various gap spacings are measured and analyzed. Results show that the flame centerline positions at a height of 4.0-6.0 cm are regarded as the main reaction zone. The breakdown processes of rod-plane gaps in ethanol flames are the combined results of diverse discharge patterns. Compared with the pure air case, the breakdown voltages are decreased by 27.8%-70.5% in the nonbridged gap and by 68.3%-77.1% in the bridged gap by ethanol flames, and their corresponding levels of average breakdown strengths decrease to 45.7% and 27.6%, respectively. Under the alternating current (ac) electric field, the coupled effects of electric field force, thermal buoyancy, and ionic wind together promote the formations of streamer channels in ethanol flames. Finally, the high-temperature flame itself is found to be the most dominant factor in influencing the breakdown.
引用
收藏
页码:206 / 214
页数:9
相关论文
共 50 条
  • [1] CORONA, BREAKDOWN AND HUMIDITY IN THE ROD-PLANE GAP
    ALLEN, NL
    IEE PROCEEDINGS-A-SCIENCE MEASUREMENT AND TECHNOLOGY, 1986, 133 (08): : 562 - 568
  • [2] Impulse breakdown behavior of rod-plane gap under high temperature
    He, Xiaowei
    Wang, Liming
    Liang, Xidong
    Guan, Zhicheng
    2000, Sci Publ House (26):
  • [3] Effect of a floating conductor on the breakdown performance of a rod-plane air gap
    Yang, Guanghua
    Wang, Shenghui
    Chen, Weijiang
    Lv, Fangcheng
    Han, Bing
    Wang, Xiaoyu
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 3160 - 3163
  • [4] Effect of Humidity on Corona Characteristics Under Rod-Plane Gap
    Wu, Dengjin
    Mei, Hongwei
    Shao, Tianying
    Wang, Liming
    PROCEEDINGS OF THE 21ST INTERNATIONAL SYMPOSIUM ON HIGH VOLTAGE ENGINEERING, VOL 2, 2020, 599 : 359 - 366
  • [5] Switching Impulse Breakdown Characteristics of Large Sphere-plane Air Gaps compared with Rod-plane Air Gap
    Chen, She
    Zeng, Rong
    Zhuang, Chijie
    Yu, Zhanqing
    He, Jinliang
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2013, 20 (03) : 839 - 844
  • [6] HUMIDITY INFLUENCE ON SWITCHING IMPULSE BREAKDOWN OF A 50 CM ROD-PLANE GAP
    HAHN, G
    ZACKE, P
    FISCHER, A
    BOECKER, H
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1976, 95 (04): : 1145 - 1152
  • [7] Effect of Humidity on Lightning impulse Breakdown of Short Rod-Plane Air Gap
    Mandela, K.
    Jegadeeshkumar, M.
    Usa, S.
    4TH INTERNATIONAL CONFERENCE ON CONDITION ASSESSMENT TECHNIQUES IN ELECTRICAL SYSTEMS (CATCON 2019), 2019,
  • [8] Positive lightning breakdown characteristics of short rod-plane air gaps
    Mikropoulos, Pantelis N.
    Tsouris, Petros P.
    Chatzichristodoulou, Ioannis A.
    Binias, Konstantinos K.
    2024 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATIONS, ICHVE 2024, 2024,
  • [9] Effect of Atmospheric Conditions on Discharge Characteristics of Rod-plane Air Gap
    Zhang Hao
    Liu Hui
    Duan Yubing
    Wang Bin
    Xu Ran
    Lin Ying
    Liu Rong
    2018 3RD ASIA CONFERENCE ON POWER AND ELECTRICAL ENGINEERING (ACPEE 2018), 2018, 366
  • [10] A Feature Set of Electrostatic Field Distribution to Predict Rod-plane Gap Breakdown Voltage
    Liu, Jianben
    Oiu, Zhibin
    Hou, Huasheng
    Liu, Yan
    Liao, Caibo
    Zhang, Louxing
    2021 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2021, : 506 - 509