Comparison of technetium-99m sestamibi-gated tomographic perfusion imaging with echocardiography and electrocardiography for determination of left ventricular mass

被引:12
|
作者
Williams, KA [1 ]
Lang, RM [1 ]
Reba, RC [1 ]
Taillon, LA [1 ]
机构
[1] UNIV CHICAGO,DEPT RADIOL NUCL MED,CHICAGO,IL 60637
来源
AMERICAN JOURNAL OF CARDIOLOGY | 1996年 / 77卷 / 09期
关键词
D O I
10.1016/S0002-9149(97)89211-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Left ventricular (LV) mass estimates obtained from poststress gated single-photon emission computed tomographic (SPECT) perfusion images were compared with 2-dimensionally targeted M-mode echocardiograms and with resting electrocardiographic voltage in 32 patients with stress perfusion scans that were either normal or only mildly abnormal, Myocardial pixel volumes were obtained from SPECT transaxial slices at end-diastole, end-systole, and summed (''ungated'') static reformatted SPECT images at 2 levels of background subtraction, 37.5% and 35% of peak myocardial activity. The S-wave amplitude in lead V-1 and the R-wave amplitude in V-5 were summed for an electrocardiographic index of voltage. Echocardiographic LV moss was calculated using the modified Penn convention formula. SPECT myocardial mass estimates were significantly greater at diastole when compared with systolic or summed images, There was a moderate, although highly significant, correlation bs!tween echocardiographic and SPECT indexes of LV mass with the lower (35%) background threshold (r = 0.59, 0.60, and 0.53 for diastole, summed, and systole, each p < 0.001), The diastolic SPECT estimate of LV mass correlation with electrocardiographic voltage (r = 0.56) was superior to the correlation between echocardiography and electrocardiography (r = 0.30). With use of published criteria for the presence of LV hypertrophy on echocardiography, diastolic and systolic gated SPECT predicted echocardiographic results with 78% accuracy.
引用
收藏
页码:750 / 755
页数:6
相关论文
共 50 条
  • [1] Myocardial perfusion and angiographic findings in patients with paradoxical sinus deceleration during dobutamine technetium-99m sestamibi-gated SPECT imaging
    Emre, A
    Ersek, B
    Gürsürer, M
    Aksoy, M
    CARDIOLOGY, 1999, 92 (03) : 183 - 188
  • [2] Parathyroid imaging with technetium-99m sestamibi
    Fujii, H
    Kubo, A
    BIOMEDICINE & PHARMACOTHERAPY, 2000, 54 : 12S - 16S
  • [3] Factors influencing resting left ventricular ejection fraction measurements by technetium-99m sestamibi myocardial perfusion gated SPECT.
    Yao, SS
    Chandra, P
    Cohen, R
    Nichols, K
    DePuey, EG
    Rozanski, A
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 45P - 45P
  • [4] Influence of arm positioning on rest/stress technetium-99m labeled sestamibi tomographic myocardial perfusion imaging
    Toma, DM
    White, MP
    Mann, A
    Phillips, JM
    Pelchat, DA
    Giri, S
    Ucrós, GR
    Heller, GV
    JOURNAL OF NUCLEAR CARDIOLOGY, 1999, 6 (02) : 163 - 168
  • [5] Influence of arm positioning on rest/stress technetium-99m labeled sestamibi tomographic myocardial perfusion imaging
    Dawn M. Toma
    Michael P. White
    April Mann
    Joseph M. Phillips
    Denise A. Pelchat
    Satyendra Giri
    Gonzalo R. Ucrós
    Gary V. Heller
    Journal of Nuclear Cardiology, 1999, 6 : 163 - 168
  • [6] PERFUSABLE MYOCARDIAL MASS WITH TC-99M-SESTAMIBI GATED SPECT - COMPARISON WITH ECHOCARDIOGRAPHY AND ELECTROCARDIOGRAPHY
    WILLIAMS, KA
    TAILLON, LA
    LANG, RM
    REBA, RC
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) : P26 - P26
  • [7] EGG-gated rubidium-82 myocardial perfusion PET imaging: A multiexpert comparison with technetium-99m sestamibi SPECT
    Bateman, TM
    McGhie, AL
    Heller, GV
    Moutray, KL
    Bryngelson, JR
    Moser, KW
    Case, JA
    Cullom, SJ
    Reid, KJ
    Friedman, JD
    CIRCULATION, 2004, 110 (17) : 611 - 611
  • [8] Influence of clinical, angiographic, and perfusion factors on left ventricular end-diastolic volume measured by technetium-99m sestamibi myocardial perfusion gated SPECT
    Yao, SS
    Palmas, W
    Chandra, P
    Dorbala, S
    Sharma, A
    Nichols, K
    DePuey, EG
    Rozanski, A
    CIRCULATION, 1998, 98 (17) : 167 - 167
  • [9] Prognostic value of technetium-99m sestamibi gated SPECT imaging with dobutamine stress
    Fowler, MS
    Katten, DM
    Mather, JF
    Ahlberg, AW
    McGill, CC
    Hudson, W
    Johnson, LL
    Heller, GV
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 437A - 438A
  • [10] Assessment of Left Ventricular Systolic and Diastolic Function Using ECG-Gated Technetium-99m Tetrofosmin Myocardial Perfusion SPECT Comparison With Ultrasound Echocardiography
    Mizunobu, Mayumi
    Sakai, Jun
    Sasao, Hisataka
    Murai, Hiroshi
    Fujiwara, Hidetoshi
    INTERNATIONAL HEART JOURNAL, 2013, 54 (04) : 212 - 215