Simultaneous determination of the size and concentration of AgNPs in water samples by UV-vis spectrophotometry and chemometrics tools

被引:28
|
作者
Moreno-Martin, Gustavo [1 ]
Eugenia Leon-Gonzalez, Maria [1 ]
Madrid, Yolanda [1 ]
机构
[1] Univ Complutense Madrid, Fac Ciencias Quim, Dept Quim Analit, E-28040 Madrid, Spain
关键词
AgNPs; UV-vis spectrophotometry; Water; Experimental design; Multivariate calibration; PLS; COATED SILVER NANOPARTICLES; TOXICITY; STABILITY; KINETICS; AGGREGATION; DISSOLUTION; EXPOSURE; CHLORIDE; RELEASE; CITRATE;
D O I
10.1016/j.talanta.2018.06.009
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The combination of UV-vis spectrophotometry with a chemometric calibration tool based on partial least squares (PLS) has allowed us the development of a multivariate analytical method that simultaneously estimates the concentration and size of mixtures of silver nanoparticles (AgNPs) in environmental water samples. The method is based on changes in the surface plasmon resonance band (SPRB) of AgNPs when they form aggregated/assembled structures with L-cysteine (L-cys). Measurementts were performed by employed a fixed-time kinetics method that implies that the final spectra (response) are obtained by subtstracting the solutions spectra at fixed times. Optimization of experimental conditions affecting aggregation such as time, temperature, pH and concentration of aggregating substance was performed by experimental design and response surface methodologies (RSM). A multivariate calibration model using AgNPs of known diameter size ((20 +/- 3), (41 +/- 3), (59 +/- 5) and (79 +/- 7) nm) within a concentration range between 0.62 and 2.5 mg L-1 was constructed by using a mixture experimental design and PLS. The method was finally applied to estimate size and concentration of AgNPs in AgNPs-spiked river and tap water samples. Water samples were spiked with individual, binary and ternary mixtures of AgNPs of different sizes and by using two types of AgNPs: citrate-coated AgNPs (cit-AgNPs) and polyvinylpyrrolidone-coated AgNPs (PVP-AgNPs). A good correspondence was obtained between predicted values and the total amount of AgNPs added with recovery values ranged within 80-160% for the individual mixtures, 68-108% for the binary mixtures and 60-64% for the ternary mixtures of AgNPs. Finally, transmission electron microscopy (TEM) measurements were performed for those cases where discrepancies between the expected and the obtained values were observed. TEM micrographs evidenced the presence of agglomerates or aggregates of AgNPs in some of the mixtures or water tested.
引用
收藏
页码:393 / 403
页数:11
相关论文
共 50 条
  • [1] Determination of Trihalomethanes in Tap Water by UV-Vis Spectrophotometry
    Zavar, M. H. Arbab
    Rounaghi, G. H.
    Chamsaz, M.
    Ashraf, N.
    ASIAN JOURNAL OF CHEMISTRY, 2009, 21 (04) : 2903 - 2910
  • [2] UV-VIS spectrophotometry: Automated determination of pathlength in microplate samples
    McGown, EL
    Nelson, JW
    Williams, J
    Fraser, C
    AMERICAN LABORATORY, 1997, 29 (11) : 21 - &
  • [3] Photodegradation Study of Nystatin by UV-Vis Spectrophotometry and Chemometrics Modeling
    Hemmateenejad, Bahram
    Nekoeinia, Mohsen
    Absalan, Ghodratollah
    Ansari, Mehdi
    JOURNAL OF AOAC INTERNATIONAL, 2014, 97 (04) : 1206 - 1212
  • [4] Simultaneous multicomponent analysis by UV-VIS spectrophotometry.
    Saldanha, TCB
    de Araújo, MCU
    Neto, BD
    QUIMICA NOVA, 1999, 22 (06): : 847 - 853
  • [5] Use of Dispersive Liquid-Liquid Microextraction and UV-Vis Spectrophotometry for the Determination of Cadmium in Water Samples
    Perez-Outeiral, J.
    Millan, E.
    Garcia-Arrona, R.
    JOURNAL OF SPECTROSCOPY, 2014, 2014
  • [6] Determination of Trace Inorganic Mercury Species in Water Samples by Cloud Point Extraction and UV-Vis Spectrophotometry
    Ulusoy, Halil Ibrahim
    JOURNAL OF AOAC INTERNATIONAL, 2014, 97 (01) : 238 - 244
  • [7] Colorimetric Sensor Based AgNPs for the Detection of Cyanide using UV-Vis Spectrophotometry
    Girgin, Ayca
    Akbiyik, Hilal
    Zaman, Buse Tugba
    Cetin, Gulten
    Bakirdere, Sezgin
    CHEMISTRYSELECT, 2023, 8 (33):
  • [8] Determination of olmesartan medoxomil in tablets by UV-Vis spectrophotometry
    Celebier, M.
    Altinoz, S.
    PHARMAZIE, 2007, 62 (06): : 419 - 422
  • [9] Determination of lead(II) levels in raw chicken samples using UV-vis spectrophotometry
    Wilson, Stephanie
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 255
  • [10] Simultaneous determination of methylxanthines in coffees and teas by UV-Vis spectrophotometry and partial least squares
    López-Martínez, L
    López-de-Alba, PL
    García-Campos, R
    De León-Rodríguez, LM
    ANALYTICA CHIMICA ACTA, 2003, 493 (01) : 83 - 94