High-accuracy simultaneous measurement of particle size and location using interferometric out-of-focus imaging

被引:25
|
作者
Lu Qieni [1 ]
Kan, Han [1 ]
Baozhen, Ge [1 ]
Xiang, Wang [1 ]
机构
[1] Tianjin Univ, Sch Precis Instrument & Optoelect Engn, Key Lab Optoelect Informat Technol, Minist Educ, Tianjin 300072, Peoples R China
来源
OPTICS EXPRESS | 2016年 / 24卷 / 15期
基金
中国国家自然科学基金;
关键词
SIZING TECHNIQUES; SCATTERING; DIAMETER; SYSTEMS;
D O I
10.1364/OE.24.016530
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A method based on unidirectional gradient-matched algorithm and Fourier transform technique is proposed to simultaneously extract the location and the number of fringes/fringe spacing of a particle interferogram. The position coordinate (x, y) of a particle can be determined with high accuracy because of the elimination of the fringe within the particle fringe pattern. Furthermore, the method can be employed to achieve sub-pixel frequency extraction when combined with an improved Rife algorithm. The performance of the method has been verified by numerical simulations and experimental measurements. The results suggest that the method presented here is highly beneficial to applications such as spray, in accurately measuring both the particle size and its location. (C) 2016 Optical Society of America
引用
收藏
页码:16530 / 16543
页数:14
相关论文
共 50 条
  • [1] Simultaneous 3D location and size measurement of spherical bubbles using cylindrical interferometric out-of-focus imaging
    Shen, H.
    Coetmellec, S.
    Brunel, M.
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2013, 131 : 153 - 159
  • [2] Determination of the Size of Irregular Particles Using Interferometric Out-of-Focus Imaging
    Brunel, Marc
    Shen, Huanhuan
    Coetmellec, Sebastien
    Grehan, Gerard
    Delobel, Tony
    INTERNATIONAL JOURNAL OF OPTICS, 2014, 2014
  • [3] Simultaneous interferometric in-focus and out-of-focus imaging of ice crystals
    Kielar, Justin Jacquot
    Lemaitre, Pascal
    Gobin, Carole
    Wu, Yingchun
    Porcheron, Emmanuel
    Coetmellec, Sebastien
    Grehan, Gerard
    Brunel, Marc
    OPTICS COMMUNICATIONS, 2016, 372 : 185 - 195
  • [4] High-accuracy particle sizing by interferometric particle imaging
    Lue Qieni
    Jin Wenhua
    Tong, Lue
    Xiang, Wang
    Zhang Yimo
    OPTICS COMMUNICATIONS, 2014, 312 : 312 - 318
  • [5] Interferometric out-of-focus imaging of freezing droplets
    Brunel, Marc
    Talbi, Mohamed
    Coetmellec, Sebastien
    Grehan, Gerard
    Wu, Yingchun
    Jacquot-Kielar, Justin
    OPTICS COMMUNICATIONS, 2019, 433 : 173 - 182
  • [6] Numerical investigation of error rates in rough particle sizing using interferometric out-of-focus imaging
    Brunel, Marc
    Talbi, Mohamed
    Ouldarbi, Lila
    Coetmellec, Sebastien
    Grehan, Gerard
    OPTIK, 2017, 147 : 204 - 213
  • [7] Fast and high-accuracy measurement of particle size and location from a linear interferogram
    Lu, Qieni
    Liu, Hao
    Wang, Huaying
    Liu, Taiyu
    Song, Tianhui
    APPLIED OPTICS, 2022, 61 (25) : 7482 - 7489
  • [8] Automatic acquisition of particle orientation by interferometric out-of-focus image
    Sun, Jinlu
    Zhang, Hongxia
    Fan, Wenbo
    Chen, Shengyong
    OPTICS COMMUNICATIONS, 2021, 486
  • [9] Instrumentation for ice crystal characterization in laboratory using interferometric out-of-focus imaging
    Brunel, M.
    Demange, G.
    Fromager, M.
    Talbi, M.
    Zapolsky, H.
    Patte, R.
    Ameur, K. Ait
    Jacquot-Kielar, J.
    Coetmellec, S.
    Grehan, G.
    Quevreux, B.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (08):
  • [10] Cylindrical interferometric out-of-focus imaging for the analysis of droplets in a volume
    Shen, Huanhuan
    Coetmellec, Sebastien
    Brunel, Marc