Respiratory protection provided by N95 filtering facepiece respirators against airborne dust and microorganisms in agricultural farms

被引:57
|
作者
Lee, SA [1 ]
Adhikari, A [1 ]
Grinshpun, SA [1 ]
McKay, R [1 ]
Shukla, R [1 ]
Zeigler, HL [1 ]
Reponen, T [1 ]
机构
[1] Univ Cincinnati, Dept Environm Hlth, Cincinnati, OH 45267 USA
关键词
agricultural farms; airborne dust; airborne microorganisms; respirators; workplace protection factor; WPF;
D O I
10.1080/15459620500330583
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A new system was used to determine the workplace protection factors (WPF) for dust and bioaerosols in agricultural environments. The field study was performed with a subject wearing an N95 filtering facepiece respirator while performing animal feeding, grain harvesting and unloading, and routine investigation of facilities. As expected, the geometric means (GM) of the WPFs increased with increasing particle size ranging from 21 for 0.7-1 mu m particles to 270 for 5-10 mu m particles (p < 0.001). The WPF for total culturable fungi (GM = 35) was significantly greater than for total culturable bacteria (GM = 9) (p = 0.01). Among the different microorganism groups, the WPFs of Cladosporium, culturable fungi, and total fungi were significantly correlated with the WPFs of particles of the same sizes. As compared with the WPFs for dust particles, the WPFs for bioaerosols were found more frequently below 10, which is a recommended assigned protection factor (APF) for N95 filtering facepiece respirators. More than 50% of the WPFs for microorganisms (mean aerodynamic diameter < 5 mu m) were less than the proposed APF of 10. Even lower WPFs were calculated after correcting for dead space and lung deposition. Thus, the APF of 10 for N95 filtering facepiece respirators seems inadequate against microorganisms (mean aerodynamic size < 5 mu m). These results provide useful pilot data to establish guidelines for respiratory protection against airborne dust and microorganisms on agricultural farms. The method is a promising tool for further epidemiological and intervention studies in agricultural and other similar occupational and nonoccupational environments.
引用
收藏
页码:577 / 585
页数:9
相关论文
共 50 条
  • [1] Field Evaluation of N95 Filtering Facepiece Respirators on Construction Jobsites for Protection against Airborne Ultrafine Particles
    Adhikari, Atin
    Mitra, Aniruddha
    Rashidi, Abbas
    Ekpo, Imaobong
    Schwartz, Jacob
    Doehling, Jefferson
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2018, 15 (09)
  • [2] Thermal Burden of N95 Filtering Facepiece Respirators
    Roberge, Raymond
    Benson, Stacey
    Kim, Jung-Hyun
    ANNALS OF OCCUPATIONAL HYGIENE, 2012, 56 (07): : 808 - 814
  • [3] Laboratory and field evaluation of a new personal sampling system for assessing the protection provided by the N95 filtering facepiece - Respirators against particles
    Lee, SA
    Grinshpun, SA
    Adhikari, A
    Li, WX
    McKay, R
    Maynard, A
    Reponen, T
    ANNALS OF OCCUPATIONAL HYGIENE, 2005, 49 (03): : 245 - 257
  • [4] Multicycle Autoclave Decontamination of N95 Filtering Facepiece Respirators
    Bopp, Nathen E.
    Bouyer, Donald H.
    Gibbs, Christopher M.
    Nichols, Joan E.
    Ntiforo, Corrie A.
    Grimaldo, Miguel A.
    APPLIED BIOSAFETY, 2020, 25 (03) : 150 - 156
  • [5] Respiratory protection against Mycobacterium tuberculosis:: Quantitative fit test outcomes for five Type N95 filtering-facepiece respirators
    Lee, K
    Slavcev, A
    Nicas, M
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2004, 1 (01) : 22 - 28
  • [6] Heat and Humidity for Bioburden Reduction of N95 Filtering Facepiece Respirators
    Anderegg, Loic
    Doyle, John
    Gardel, Margaret L.
    Gupta, Amit
    Hallas, Christian
    Lensky, Yuri
    Love, Nancy G.
    Lucas, Bronwyn A.
    Mazenc, Edward
    Meisenhelder, Cole
    Pillarisetti, Ajay
    Ranard, Daniel
    Squires, Allison H.
    Vechakul, Jessica
    Vilas, Nathaniel B.
    Williams, Stuart
    Wilson, Daniel
    Chen, Tyler N.
    APPLIED BIOSAFETY, 2021, 26 (02) : 80 - 89
  • [7] Fitting characteristics of eighteen N95 filtering-facepiece respirators
    Coffey, CC
    Lawrence, RB
    Campbell, DL
    Zhuang, ZQ
    Calvert, CA
    Jensen, PA
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2004, 1 (04) : 262 - 271
  • [8] Physiological and Thermoregulatory Responses to Wearing N95 Filtering Facepiece Respirators
    Kim, Jung-Hyun
    Roberge, Raymond J.
    Benson, Stacey M.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 : 319 - 319
  • [9] Hydrogen Peroxide Methods for Decontaminating N95 Filtering Facepiece Respirators
    Rempel, David
    Henneman, John
    Agalloco, James
    Crittenden, Jill
    APPLIED BIOSAFETY, 2021, 26 (02) : 71 - 79
  • [10] Evaluation of N95 Filtering Facepiece Respirators Challenged with Engineered Nanoparticles
    Zhou, Yue
    Cheng, Yung Sung
    AEROSOL AND AIR QUALITY RESEARCH, 2016, 16 (01) : 212 - 220