Comparison of partially-absorbable lightweight mesh with heavyweight mesh for inguinal hernia repair: multicenter randomized study

被引:9
|
作者
Lee, Seong Dae [1 ]
Son, Taeil [2 ]
Lee, Jae-Bum [1 ]
Chang, Yeon Soo [2 ]
机构
[1] Daehang Hosp, Dept Surg, Seoul, South Korea
[2] Eulji Univ, Coll Med, Eulji Med Ctr, Dept Surg, 68 Hangeulbiseong Ro, Seoul 01830, South Korea
关键词
Inguinal hernia; Surgical mesh; Quality of life; PAIN; HERNIORRHAPHY; METAANALYSIS; SCALES; TRIAL;
D O I
10.4174/astr.2017.93.6.322
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: Prosthetic mesh is widely used for inguinal hernia repair; however, pain and stiffness can develop. This study was a prospective, multicenter, single-blind, randomized trial to assess postoperative pain and quality of life according to mesh type after inguinal hernia repair. Methods: Forty-seven patients who underwent Lichtenstein repair for unilateral inguinal hernia with prosthetic mesh were enrolled and randomly allocated to the partially-absorbable lightweight mesh (LW group, n = 24) or heavyweight mesh group (HW group, n = 23). Data were collected using a visual analogue scale (VAS), Carolinas Comfort Scale (CCS), and Activities Assessment Scale (AAS) at screening and postoperative day 1, 7, 90, and 120; foreign body sensation, sense of stiffness, and sense of pull during activity were also evaluated. Results: There were no significant differences in patients' demographics and clinical characteristics between groups. The VAS at day 90 was significantly lower in the LW group (0.46 +/- 0.78 vs. 0.96 +/- 0.82, P = 0.027). The CCS and MS were significantly lower in the LW group at day 1 (51.33 +/- 20.29 vs. 64.65 +/- 22.64, P = 0.047 and 39.83 +/- 9.88 vs. 46.43 +/- 7.82, P = 0.015, respectively). Foreign body sensation was significantly lower in the LW group at day 120 (4.2% vs. 30.4 %, P = 0.023), as was sense of stiffness (P = 0.023). The sense of pull during activity was lower in the LW group at day 90 and 120 (P = 0.012 and P = 0.022, respectively). There was no recurrence or serious complication during follow-up. Conclusion: Partially-absorbable lightweight prosthetic mesh can be used for inguinal hernia repair safely and improve functional outcomes and quality of life after surgery.
引用
收藏
页码:322 / 330
页数:9
相关论文
共 50 条
  • [1] Randomized clinical trial comparing lightweight mesh with heavyweight mesh for primary inguinal hernia repair
    A. Yazdankhah Kenary
    S. N. Afshin
    H. Ahmadi Amoli
    A. Yagoobi Notash
    A. Borjian
    A. Yagoobi Notash Jr
    S. Shafaattalab
    G. Shafiee
    Hernia, 2013, 17 : 471 - 477
  • [2] Randomized clinical trial comparing lightweight mesh with heavyweight mesh for primary inguinal hernia repair
    Kenary, A. Yazdankhah
    Afshin, S. N.
    Amoli, H. Ahmadi
    Notash, A. Yagoobi
    Borjian, A.
    Notash, A. Yagoobi, Jr.
    Shafaattalab, S.
    Shafiee, G.
    HERNIA, 2013, 17 (04) : 471 - 477
  • [3] Randomized clinical trial comparing lightweight or heavyweight mesh for mesh plug repair of primary inguinal hernia
    Hirose, T.
    Takayama, Y.
    Komatsu, S.
    Shingu, Y.
    Sakamoto, E.
    Norimizu, S.
    Hasegawa, H.
    HERNIA, 2014, 18 (02) : 213 - 219
  • [4] Randomized clinical trial comparing lightweight or heavyweight mesh for mesh plug repair of primary inguinal hernia
    T. Hirose
    Y. Takayama
    S. Komatsu
    Y. Shingu
    E. Sakamoto
    S. Norimizu
    H. Hasegawa
    Hernia, 2014, 18 : 213 - 219
  • [5] Prospective randomized controlled trial comparing partially absorbable lightweight mesh and multifilament polyester anatomical mesh in laparoscopic inguinal hernia repair
    Wong, John C. C.
    Yang, George P. C.
    Cheung, Tony P. P.
    Li, Michael K. W.
    ASIAN JOURNAL OF ENDOSCOPIC SURGERY, 2018, 11 (02) : 146 - 150
  • [6] Comment on "Heavyweight Mesh Is Superior to Lightweight Mesh in Laparo-endoscopic Inguinal Hernia Repair''
    Li, Junsheng
    ANNALS OF SURGERY, 2021, 274 (06) : E783 - E784
  • [7] Lightweight versus heavyweight mesh in laparoscopic inguinal hernia repair: a meta-analysis
    Currie, Andrew
    Andrew, Helen
    Tonsi, Alfredo
    Hurley, Paul R.
    Taribagil, Sanjay
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2012, 26 (08): : 2126 - 2133
  • [8] Lightweight versus heavyweight mesh in laparoscopic inguinal hernia repair: a meta-analysis
    Andrew Currie
    Helen Andrew
    Alfredo Tonsi
    Paul R. Hurley
    Sanjay Taribagil
    Surgical Endoscopy, 2012, 26 : 2126 - 2133
  • [9] Meta-analysis of randomized controlled trials comparing lightweight and heavyweight mesh for Lichtenstein inguinal hernia repair
    Uzzaman, M. M.
    Ratnasingham, K.
    Ashraf, N.
    HERNIA, 2012, 16 (05) : 505 - 518
  • [10] Randomized clinical trial assessing impact of a lightweight or heavyweight mesh on chronic pain after inguinal hernia repair
    O'Dwyer, PJ
    Kingsnorth, AN
    Molloy, RG
    Small, PK
    Lammers, B
    Horeyseck, G
    BRITISH JOURNAL OF SURGERY, 2005, 92 (02) : 166 - 170