Development and evaluation of isothermal amplification assay for the rapid and sensitive detection of Clostridium perfringens from chevon

被引:21
|
作者
Priya, Govindarajan Bhuvana [1 ]
Agrawal, Ravi Kant [2 ]
Milton, Arockiasamy Arun Prince [3 ]
Mishra, Madhu [1 ]
Mendiratta, Sanjod Kumar [2 ]
Agarwal, Rajesh Kumar [1 ]
Luke, Ashish [2 ]
Singh, Bhoj Raj [4 ]
Kumar, Deepak [5 ]
机构
[1] ICAR Indian Vet Res Inst, Div Bacteriol & Mycol, Izatnagar, Uttar Pradesh, India
[2] ICAR Indian Vet Res Inst, Div Livestock Prod Technol, Bareilly, Uttar Pradesh, India
[3] ICAR Res Complex North Eastern Hill Reg, Div Anim Hlth, Umiam, Meghalaya, India
[4] ICAR Indian Vet Res Inst, Div Vet Publ Hlth, Bareilly, Uttar Pradesh, India
[5] ICAR Indian Vet Res Inst, Div Vet Biotechnol, Bareilly, Uttar Pradesh, India
关键词
Clostridium perfringens diagnostics cpa; Loop-mediated isothermal amplification; Chevon; LAMP; PREVALENCE; ACCURATE; GENE; LAMP;
D O I
10.1016/j.anaerobe.2018.09.005
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Loop-mediated isothermal amplification (LAMP) is a promising, simple, rapid and sensitive molecular detection method. In the present study, LAMP assay was developed for detecting Clostridium perfringens in chevon. Primers were designed to detect the cpa gene of C. perfringens. A panel of 19 bacterial strains, including 3 C. perfringens and 16 other strains, were included in this study to standardize and evaluate the LAMP assay. No false positive amplification was observed indicating 100% specificity of the assay. The detection limit of LAMP and conventional PCR in the DNA extracted from pure C perfringens was 0.34 pg and 3.4 pg, respectively. This revealed that LAMP assay is 10 times more sensitive than conventional PCR. The sensitivity of the LAMP assay for the detection of C perfringens in raw chevon was found to be 1.2 x 10(2) CFU/g after 6-h enrichment and 1.2 x 10(5) CFU/g without enrichment in artificial spiking studies. Improved C perfringens detection of 12 CFU/g within 12 h was obtained proving that LAMP assay is significantly faster than traditional methods that take >2 d. The developed LAMP assay also detected the targeted organism in clinical and environmental samples with the sensitivity and specificity of 97% and 84%, respectively with Kappa agreement of 0.824 respects to PCR assay. This method shows immense potential for routine diagnosis and monitoring of C perfringens in food, environment and clinical samples. This is the first report in which the LAMP assay was optimized for the detection of C perfringens in chevon. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:178 / 187
页数:10
相关论文
共 50 条
  • [1] Development and application of the loop-mediated isothermal amplification assay for rapid detection of enterotoxigenic Clostridium perfringens in food
    Hong, Joonbae
    JOURNAL OF FOOD SAFETY, 2017, 37 (04)
  • [2] Optimization of a loop-mediated isothermal amplification (lamp) assay for the rapid detection of Clostridium perfringens
    Chaudhary, Deepa
    Poudel, Sabin
    Jia, Linan
    Sukumaran, Anuraj Theradiyil
    Zhang, Xue
    Cheng, Wen-Hsing
    Kiess, Aaron S.
    Macklin, Kenneth S.
    Zhang, Li
    JOURNAL OF APPLIED POULTRY RESEARCH, 2025, 34 (02):
  • [3] Rapid, Sensitive, and Specific Detection of Clostridium tetani by Loop-Mediated Isothermal Amplification Assay
    Jiang Dongneng
    Pu, Xiaoyun
    Wu, Jiehong
    Li, Meng
    Liu, Ping
    JOURNAL OF MICROBIOLOGY AND BIOTECHNOLOGY, 2013, 23 (01) : 1 - 6
  • [4] Development and Evaluation of a Loop-Mediated Isothermal Amplification Assay for Rapid and Sensitive Detection of Vibrio parahaemolyticus
    Nemoto, Jiro
    Ikedo, Masanari
    Kojima, Tadashi
    Momoda, Takayoshi
    Konuma, Hirotaka
    Hara-Kudo, Yukiko
    JOURNAL OF FOOD PROTECTION, 2011, 74 (09) : 1462 - 1467
  • [5] Isothermal amplification assay for visual on-site detection of Staphylococcus aureus in Chevon
    Priya, Govindarajan Bhuvana
    Agrawal, Ravi Kant
    Milton, Arockiasamy Arun Prince
    Mendiratta, Sanjod Kumar
    Singh, Bhoj Raj
    Kumar, Deepak
    Mishra, Madhu
    Gandham, Ravi Kumar
    FOOD BIOTECHNOLOGY, 2021, 35 (03) : 221 - 236
  • [6] Development of a loop-mediated isothermal amplification assay for sensitive and rapid detection of Mycoplasma bovis
    Bai, ZhiDi
    Shi, Lei
    Hu, Changmin
    Chen, Xi
    Qi, Jingjing
    Ba, Xiaoliang
    Peng, Qingjie
    Chen, Yingyu
    Chen, Huanchun
    Guo, Aizhen
    AFRICAN JOURNAL OF BIOTECHNOLOGY, 2011, 10 (57): : 12333 - 12338
  • [7] Development of a loop-mediated Isothermal amplification assay for sensitive and rapid detection of Vibrio parahaemolyticus
    Wataru Yamazaki
    Masanori Ishibashi
    Ryuji Kawahara
    Kiyoshi Inoue
    BMC Microbiology, 8
  • [8] Development of a loop-mediated isothermal amplification assay for sensitive and rapid detection of Campylobacter fetus
    Yamazaki, Wataru
    Taguchi, Masumi
    Ishibashi, Masanori
    Nukina, Masafumi
    Misawa, Naoaki
    Inoue, Kiyoshi
    VETERINARY MICROBIOLOGY, 2009, 136 (3-4) : 393 - 396
  • [9] Development of a loop-mediated Isothermal amplification assay for sensitive and rapid detection of Vibrio parahaemolyticus
    Yamazaki, Wataru
    Ishibashi, Masanori
    Kawahara, Ryuji
    Inoue, Kiyoshi
    BMC MICROBIOLOGY, 2008, 8 (1)
  • [10] Development of a Loop-Mediated Isothermal Amplification Assay for Sensitive and Rapid Detection of Cronobacter sakazakii
    Fan, Hongying
    Long, Beiguo
    Wu, Xianbo
    Bai, Yang
    FOODBORNE PATHOGENS AND DISEASE, 2012, 9 (12) : 1111 - 1118