Time to Recognition of Sepsis in the Emergency Department Using Electronic Health Record Data: A Comparative Analysis of Systemic Inflammatory Response Syndrome, Sequential Organ Failure Assessment, and Quick Sequential Organ Failure Assessment

被引:28
|
作者
Prasad, Priya A. [1 ]
Fang, Margaret C. [1 ]
Abe-Jones, Yumiko [1 ]
Calfee, Carolyn S. [2 ]
Matthay, Michael A. [2 ,3 ,4 ]
Kangelaris, Kirsten N. [1 ]
机构
[1] Univ Calif San Francisco, Dept Med, Div Hosp Med, San Francisco, CA 94143 USA
[2] Univ Calif San Francisco, Dept Med, Pulm & Crit Care Med, San Francisco, CA 94143 USA
[3] Univ Calif San Francisco, Dept Anesthesia, San Francisco, CA USA
[4] Univ Calif San Francisco, Cardiovasc Res Inst, San Francisco, CA 94143 USA
基金
美国国家卫生研究院;
关键词
critical care; electronic health records; emergency medicine; organ dysfunction scores; sepsis; systemic inflammatory response syndrome; INTERNATIONAL CONSENSUS DEFINITIONS; IN-HOSPITAL MORTALITY; CLINICAL-CRITERIA; SEPTIC SHOCK; SIRS CRITERIA; QSOFA SCORE;
D O I
10.1097/CCM.0000000000004132
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: Early identification of sepsis is critical to improving patient outcomes. Impact of the new sepsis definition (Sepsis-3) on timing of recognition in the emergency department has not been evaluated. Our study objective was to compare time to meeting systemic inflammatory response syndrome (Sepsis-2) criteria, Sequential Organ Failure Assessment (Sepsis-3) criteria, and quick Sequential Organ Failure Assessment criteria using electronic health record data. Design: Retrospective, observational study. Setting: The emergency department at the University of California, San Francisco. Patients: Emergency department encounters between June 2012 and December 2016 for patients greater than or equal to 18 years old with blood cultures ordered, IV antibiotic receipt, and identification with sepsis via systemic inflammatory response syndrome or Sequential Organ Failure Assessment within 72 hours of emergency department presentation. Interventions: None. Measurements and Main Results: We analyzed timestamped electronic health record data from 16,612 encounters identified as sepsis by greater than or equal to 2 systemic inflammatory response syndrome criteria or a Sequential Organ Failure Assessment score greater than or equal to 2. The primary outcome was time from emergency department presentation to meeting greater than or equal to 2 systemic inflammatory response syndrome criteria, Sequential Organ Failure Assessment greater than or equal to 2, and/or greater than or equal to 2 quick Sequential Organ Failure Assessment criteria. There were 9,087 patients (54.7%) that met systemic inflammatory response syndrome-first a median of 26 minutes post-emergency department presentation (interquartile range, 0-109 min), with 83.1% meeting Sequential Organ Failure Assessment criteria a median of 118 minutes later (interquartile range, 44-401 min). There were 7,037 patients (42.3%) that met Sequential Organ Failure Assessment-first, a median of 113 minutes post-emergency department presentation (interquartile range, 60-251 min). Quick Sequential Organ Failure Assessment was met in 46.4% of patients a median of 351 minutes post-emergency department presentation (interquartile range, 67-1,165 min). Adjusted odds of in-hospital mortality were 39% greater in patients who met systemic inflammatory response syndrome-first compared with those who met Sequential Organ Failure Assessment-first (odds ratio, 1.39; 95% CI, 1.20-1.61). Conclusions: Systemic inflammatory response syndrome and Sequential Organ Failure Assessment initially identified distinct populations. Using systemic inflammatory response syndrome resulted in earlier electronic health record sepsis identification in greater than 50% of patients. Using Sequential Organ Failure Assessment alone may delay identification. Using systemic inflammatory response syndrome alone may lead to missed sepsis presenting as acute organ dysfunction. Thus, a combination of inflammatory (systemic inflammatory response syndrome) and organ dysfunction (Sequential Organ Failure Assessment) criteria may enhance timely electronic health record-based sepsis identification.
引用
收藏
页码:200 / 209
页数:10
相关论文
共 50 条
  • [1] Quick sequential organ failure assessment compared to systemic inflammatory response syndrome for predicting sepsis in emergency department
    Park, Hyun Kyung
    Kim, Won Young
    Kim, Myung Chun
    Jung, Woong
    Ko, Byuk Sung
    JOURNAL OF CRITICAL CARE, 2017, 42 : 12 - 17
  • [2] Systemic inflammatory response syndrome, sequential organ failure assessment, and quick sequential organ failure assessment: more pieces needed in the sepsis puzzle
    Du, Bin
    Weng, Li
    JOURNAL OF THORACIC DISEASE, 2017, 9 (03) : 452 - 454
  • [3] Comparison of Systemic Inflammatory Response Syndrome and quick Sequential Organ Failure Assessment scores in predicting bacteremia in the emergency department
    Furuta, Katsuyuki
    Akamatsu, Hiroaki
    Sada, Ryuichi
    Miyamoto, Kyohei
    Teraoka, Shunsuke
    Hayata, Atsushi
    Ozawa, Yuichi
    Nakanishi, Masanori
    Koh, Yasuhiro
    Yamamoto, Nobuyuki
    ACUTE MEDICINE & SURGERY, 2021, 8 (01):
  • [4] Quick sequential organ failure assessment versus systemic inflammatory response syndrome criteria for emergency department patients with suspected infection
    Atsushi Shiraishi
    Satoshi Gando
    Toshikazu Abe
    Shigeki Kushimoto
    Toshihiko Mayumi
    Seitaro Fujishima
    Akiyoshi Hagiwara
    Yasukazu Shiino
    Shin-ichiro Shiraishi
    Toru Hifumi
    Yasuhiro Otomo
    Kohji Okamoto
    Junichi Sasaki
    Kiyotsugu Takuma
    Kazuma Yamakawa
    Yoshihiro Hanaki
    Masahiro Harada
    Kazuma Morino
    Scientific Reports, 11
  • [5] Quick sequential organ failure assessment versus systemic inflammatory response syndrome criteria for emergency department patients with suspected infection
    Shiraishi, Atsushi
    Gando, Satoshi
    Abe, Toshikazu
    Kushimoto, Shigeki
    Mayumi, Toshihiko
    Fujishima, Seitaro
    Hagiwara, Akiyoshi
    Shiino, Yasukazu
    Shiraishi, Shin-ichiro
    Hifumi, Toru
    Otomo, Yasuhiro
    Okamoto, Kohji
    Sasaki, Junichi
    Takuma, Kiyotsugu
    Yamakawa, Kazuma
    Hanaki, Yoshihiro
    Harada, Masahiro
    Morino, Kazuma
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [6] What Comes First in Sepsis- Systemic Inflammatory Response Syndrome (SIRS), the Sequential Organ Failure Assessment (SOFA), or the Quick Sepsis Related Organ Failure Assessment (qSOFA)?
    Prasad, P. A.
    Fang, M. C.
    Van Groningen, N.
    Abe-Jones, Y.
    Calfee, C. S.
    Matthay, M. A.
    Kangelaris, K. N.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2018, 197
  • [7] Validation of a Sequential Organ Failure Assessment Score using Electronic Health Record Data
    Luis E. Huerta
    Jonathan P. Wanderer
    Jesse M. Ehrenfeld
    Robert E. Freundlich
    Todd W. Rice
    Matthew W. Semler
    Journal of Medical Systems, 2018, 42
  • [8] Validation of a Sequential Organ Failure Assessment Score using Electronic Health Record Data
    Huerta, Luis E.
    Wanderer, Jonathan P.
    Ehrenfeld, Jesse M.
    Freundlich, Robert E.
    Rice, Todd W.
    Semler, Matthew W.
    JOURNAL OF MEDICAL SYSTEMS, 2018, 42 (10)
  • [9] Comparison of the systematic Inflammatory response syndrome and the quick sequential organ failure assessment for prognostic accuracy in detecting sepsis in the emergency department: A systematic review
    Svendsen, Marius
    Steindal, Simen A.
    Larsen, Marie Hamilton
    Solberg, Marianne Trygg
    INTERNATIONAL EMERGENCY NURSING, 2023, 66
  • [10] Sepsis death risk factor score based on systemic inflammatory response syndrome, quick sequential organ failure assessment, and comorbidities
    Orsatti, Vinicius Nakad
    Tasca Ribeiro, Victoria Stadler
    Montenegro, Carolina de Oliveira
    Costa, Clarice Juski
    Raboni, Eduardo Albanske
    Sampaio, Eduardo Ramos
    Michielin, Fernando
    Gasparetto, Juliano
    Telles, Joo Paulo
    Tuon, Felipe Francisco
    MEDICINA INTENSIVA, 2024, 48 (05) : 263 - 271