Reduced-cost Chlamydia trachomatis-specific multiplex real-time PCR diagnostic assay evaluated for ocular swabs and use by trachoma research programmes

被引:18
|
作者
Butcher, Robert [1 ]
Houghton, Jo [1 ]
Derrick, Tamsyn [1 ,2 ]
Ramadhani, Athumani [1 ,2 ]
Herrera, Beatriz [1 ]
Last, Anna R. [1 ]
Massae, Patrick A. [2 ]
Burton, Matthew J. [1 ]
Holland, Martin J. [1 ]
Roberts, Chrissy H. [1 ]
机构
[1] London Sch Hyg & Trop Med, Clin Res Dept, Fac Infect & Trop Dis, London WC1E 7HT, England
[2] Kilimanjaro Christian Med Ctr, Moshi, Tanzania
基金
英国惠康基金;
关键词
Chlamydia trachomatis; Diagnosis; Quantitative PCR; Trachoma; LOW-PREVALENCE; MASS TREATMENT; AMPLIFICATION; AZITHROMYCIN; LOAD; DNA;
D O I
10.1016/j.mimet.2017.04.010
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Introduction: Trachoma, caused by the intracellular bacterium Chlamydia trachomatis (Ct), is the leading infectious cause of preventable blindness. Many commercial platforms are available that provide highly sensitive and specific detection of Ct DNA. However, the majority of these commercial platforms are inaccessible for population-level surveys in resource-limited settings typical to trachoma control programmes. We developed two low-cost quantitative PCR (qPCR) tests for Ct using readily available reagents on standard real-time thermocyclers. Methods: Each multiplex qPCR test targets one genomic and one plasmid Ct target in addition to an endogenous positive control for Homo sapiens DNA. The quantitative performance of the qPCR assays in clinical samples was determined by comparison to a previously evaluated droplet digital PCR (ddPCR) test. The diagnostic performance of the qPCR assays were evaluated against a commercial assay (artus C. trachomatis Plus RG PCR, Qiagen) using molecular diagnostics quality control standards and clinical samples. We examined the yield of Ct DNA prepared from five different DNA extraction kits and a cold chain-free dry-sample preservation method using swabs spiked with fixed concentrations of human and Ct DNA. Results: The qPCR assay was highly reproducible (Ct plasmid and genomic targets mean total coefficients of variance 41.5% and 48.3%, respectively). The assay detected 8/8 core specimens upon testing of a quality control panel and performed well in comparison to commercially marketed comparator test (sensitivity and specificity > 90%). Optimal extraction and sample preservation methods for research applications were identified. Conclusion: We describe a pipeline from collection to diagnosis providing the most efficient sample preservation and extraction with significant per test cost savings over a commercial qPCR diagnostic assay. The assay and its evaluation should allow control programs wishing to conduct independent research within the context of trachoma control, access to an affordable test with defined performance characteristics.
引用
收藏
页码:95 / 102
页数:8
相关论文
共 5 条
  • [1] Evaluation of a Chlamydia trachomatis-specific, commercial, real-time PCR for use with ocular swabs
    Pickering, Harry
    Holland, Martin J.
    Last, Anna R.
    Burton, Matthew J.
    Burr, Sarah E.
    PARASITES & VECTORS, 2018, 11
  • [2] Evaluation of a Chlamydia trachomatis-specific, commercial, real-time PCR for use with ocular swabs
    Harry Pickering
    Martin J. Holland
    Anna R. Last
    Matthew J. Burton
    Sarah E. Burr
    Parasites & Vectors, 11
  • [3] Evaluation of a Multiplex Real-Time PCR Assay for Detecting Chlamydia trachomatis in Vaginal Samples
    Kebbi-Beghdadi, Carole
    Aeby, Sebastien
    Baud, David
    Greub, Gilbert
    DIAGNOSTICS, 2022, 12 (05)
  • [4] The development of a multiplex real-time PCR for the detection of herpes simplex virus 1 and 2, varizella zoster virus, adenovirus and Chlamydia trachomatis from eye swabs
    Bennett, Susan
    Carman, William F.
    Gunson, Rory N.
    JOURNAL OF VIROLOGICAL METHODS, 2013, 189 (01) : 143 - 147
  • [5] Review of use of a new rapid real-time PCR, the Cepheid GeneXpert® (Xpert) CT/NG assay, for Chlamydia trachomatis and Neisseria gonorrhoeae: results for patients while in a clinical setting
    Gaydos, Charlotte A.
    EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2014, 14 (02) : 135 - 137