Accuracy of the indices of MS-39 anterior segment optical coherence tomography in the diagnosis of keratoconic corneas

被引:5
|
作者
Elkitkat, Rania S. [1 ,2 ]
Rifay, Yasser [3 ]
Gharieb, Hesham M. [1 ]
Ziada, Hossam Eldin A. [4 ]
机构
[1] Ain Shams Univ, Fac Med, Ophthalmol, Cairo, Egypt
[2] Watany Res & Dev Ctr, Cairo, Egypt
[3] Dr Rifay Ophthalmol Ctr, Ophthalmol, Rabat, Morocco
[4] Al Azhar Univ, Ophthalmol, Cairo, Egypt
关键词
MS 39 anterior segment OCT; keratoconus diagnosis; corneal imaging techniques; accuracy of keratoconus detection indices; MS 39 anterior segment OCT epithelial mapping; THICKNESS;
D O I
10.1177/11206721211063720
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To determine the normative and the cut-off values of various indices available in the MS 39 Anterior Segment Optical Coherence Tomography (MS-39 AS-OCT) for keratoconus (KC) diagnosis, and to detect the accuracy of the variable available parameters. Methods This cross sectional observational study was conducted at Dr Rifay Ophthalmology Center, Rabat, Morocco, on 172 eyes with KC (group 1) and 248 eyes of healthy controls (group 2). Participants were screened using MS-39 AS-OCT (CSO, Firenze, Italy). The investigated indices included: keratometric indices, pachymetric indices, elevation indices, Keratoconus Summary Indices (KSI), aberration indices, and epithelial mapping evaluation. Results Most of the studied indices were significantly different between both groups (P value <0.001). Twenty two indices had Area Under the Receiver Operating Curve (AUROC) values >0.950, eight of which were from the KSI. The indices with the highest AUROC values were: Root Mean Square (RMS) for the front corneal surface at 6 mm circle (AUROC = 0.996, and best cut-off >1.69 with sensitivity of 97.67% and specificity of 97.98%) and RMS per unit of area for the front surface at 6 mm circle (AUROC = 0.996, and best cut-off >0.06 with sensitivity of 97.67% and specificity of 97.98%). Epithelial thickness-derived metrics were not among the parameters with the highest accuracy. Conclusions This study presented the mean and the cut-off values for a plethora of parameters available in the MS-39 AS-OCT. The results of this study show that MS-39 AS-OCT is a valuable equipment for diagnosing keratoconic corneas, with a high accuracy detected for many parameters.
引用
收藏
页码:2116 / 2124
页数:9
相关论文
共 50 条
  • [1] Corneal Epithelial Thickness Mapping in Healthy Population Corneas Using MS-39 Anterior Segment Optical Coherence Tomography
    Alturki, Hissah Saleh
    Alsubhi, Shahad Salah
    Alhazmi, Asma
    Alhadlag, Abdulrahman
    Albalawi, Nada Saleh
    Alzoman, Musab Abdulaziz
    Aljasir, Mohammed
    Alsubaie, Majed
    Aljindan, Mohanna
    Alsomali, Abdulaziz
    CLINICAL OPHTHALMOLOGY, 2025, 19 : 249 - 259
  • [2] Anterior segment-optical coherence tomography for evaluation of the epithelium thickness profile in keratoconic corneas and normal corneas
    Eltohamy, Soha M. M.
    JOURNAL OF THE EGYPTIAN OPHTHALMOLOGICAL SOCIETY, 2021, 114 (04) : 110 - 115
  • [3] Imaging through opaque corneas using anterior segment optical coherence tomography
    Garcia, Julian P. S., Jr.
    Garcia, Patricia M. T.
    Buxton, Douglas F.
    Panarelli, Anthony
    Rosen, Richard B.
    OPHTHALMIC SURGERY LASERS & IMAGING, 2007, 38 (04) : 314 - 318
  • [4] Comparability of Measurement of Astigmatism between URk-800F Auto Refracto-keratometer and MS-39 Anterior Segment Optical Coherence Tomography in Patients with Refractive Error
    Gupta, Namrata
    Maharjan, Samrina
    Sapkota, Suman
    NEPALESE JOURNAL OF OPHTHALMOLOGY, 2023, 15 (30) : 47 - 54
  • [5] Anterior segment optical coherence tomography
    Ang, Marcus
    Baskaran, Mani
    Werkmeister, Rene M.
    Chua, Jacqueline
    Schmidl, Doreen
    dos Santos, Valentin Aranha
    Garhoefer, Gerhard
    Mehta, Jodhbir S.
    Schmetterer, Leopold
    PROGRESS IN RETINAL AND EYE RESEARCH, 2018, 66 : 132 - 156
  • [6] Optical coherence tomography of the anterior segment
    Simpson, Trefford
    Optom, Dip
    Fonn, Desmond
    Optom, Dip
    Optom, M.
    OCULAR SURFACE, 2008, 6 (03): : 117 - 127
  • [7] Anterior Segment Optical Coherence Tomography
    Stockman, Adam
    CORNEA, 2018, 37 : S9 - S10
  • [8] Anterior Segment Optical Coherence Tomography
    Jancevski, Maria
    Foster, C. Stephen
    SEMINARS IN OPHTHALMOLOGY, 2010, 25 (5-6) : 317 - 323
  • [9] Repeatability and Comparison of Corneal Tomography in Mild to Severe Keratoconus Between the Anterior Segment OCT MS-39 and Pentacam HR
    Seiler, Theo G.
    Mueller, Maya
    Baiao, Tiago Mendes
    JOURNAL OF REFRACTIVE SURGERY, 2022, 38 (04) : 250 - +
  • [10] Accuracy of cornea and lens biometry using anterior segment optical coherence tomography
    Dunne, Mark C. M.
    Davies, Leon N.
    Wolffsohn, James S.
    JOURNAL OF BIOMEDICAL OPTICS, 2007, 12 (06)