Purpose To evaluate the outcome of a web-based digital assessment of visual acuity and refractive error, compared to a conventional supervised assessment, in keratoconus patients with complex refractive errors. Material and methods Keratoconus patients, aged 18 to 40, with a refractive error between -6 and +4 diopters were considered eligible. An uncorrected visual acuity and an assessment of refractive error was taken web-based (index test) and by manifest refraction (reference test) by an optometrist. Corrected visual acuity was assessed with the prescription derived from both the web-based tool and the manifest refraction. Non-inferiority was defined as the 95% limits-of-agreement (95%LoA) of the differences in spherical equivalent between the index and reference test not exceeding +/- 0.5 diopters. Agreement was assessed by a Bland-Altman analyses. Results A total of 100 eyes of 50 patients were examined. The overall mean difference of the uncorrected visual acuity measured -0.01 LogMAR (95%LoA:-0.63-0.60). The variability of the differences decreased in the better uncorrected visual acuity subgroup (95%LoA:-0.25-0.55). The overall mean difference in spherical equivalent between the index and reference test exceeded the non-inferiority margin: -0.58D (95%LoA:-4.49-3.33, P = 0.008). The mean differences for myopic and hyperopic subjects were 0.09 diopters (P = 0.675) and -2.06 diopters (P<0.001), respectively. The corrected visual acuities attained with the web-based derived prescription underachieved significantly (0.22 +/- 0.32 logMAR vs. -0.01 +/- 0.13 LogMAR, P <0.001). Conclusions Regarding visual acuity, the web-based tool shows promising results for remotely assessing visual acuity in keratoconus patients, particularly for subjects within a better visual acuity range. This could provide physicians with a quantifiable outcome to enhance teleconsultations, especially relevant when access to health care is limited. Regarding the assessment of the refractive error, the web-based tool was found to be inferior to the manifest refraction in keratoconus patients. This study underlines the importance of validating digital tools and could serve to increase overall safety of the web-based assessments by better identification of outlier cases.
引用
收藏
页数:13
相关论文
共 41 条
  • [1] The evaluation of a web-based tool for measuring the uncorrected visual acuity and refractive error in keratoconus eyes: A method comparison study (vol 16, e0256087, 2021)
    Muijzer, Marc B.
    Claessens, Janneau L. J.
    Cassano, Francesco
    Godefrooij, Daniel A.
    Prevoo, Yves F. D. M.
    Wisse, Robert P. L.
    [J]. PLOS ONE, 2021, 16 (12):
  • [2] The evaluation of a web-based tool for measuring the uncorrected visual acuity and refractive error in keratoconus eyes: A method comparison study (vol 16, e0256087, 2021)
    Muijzer, M. B.
    Claessens, J. L. J.
    Cassano, F.
    Godefrooij, D. A.
    Prevoo, Y. F. D. M.
    Wisse, R. P. L.
    [J]. PLOS ONE, 2022, 17 (04):
  • [3] Evaluating a web-based visual acuity and refractive error self-assessment tool in myopic children
    Claessens, Janneau L. J.
    Janssen, Marloes A.
    van der Zee, Casper
    Polling, Jan Roelof
    Meester-Smoor, Magda A.
    Klaver, Caroline C. W.
    Wisse, Robert P. L.
    [J]. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2024,
  • [4] Validation of an Independent Web-Based Tool for Measuring Visual Acuity and Refractive Error via the MORE (Manifest Versus Online Refractive Evaluation) Trial: Prospective Open-Label Noninferiority Clinical Trial
    Wisse, Robert P. L.
    Muijzer, Marc B.
    Cassano, Francesco
    Godefrooij, Daniel A.
    Prevoo, Yves F. D. M.
    Soeters, Nienke
    [J]. JOURNAL OF MEDICAL INTERNET RESEARCH, 2019, 21 (11)
  • [5] Evaluation of a telemedicine web-based visual acuity e-health tool in cataract patients
    Wanten, J.
    Bauer, N. J. C.
    Claessens, J. L. J.
    Berendschot, T. J. M.
    Wisse, R. P. L.
    Nuijts, R. M. M. A.
    [J]. ACTA OPHTHALMOLOGICA, 2022, 100 : 37 - 37
  • [6] The Accuracy of a Web-Based Visual Acuity Self-assessment Tool Performed Independently by Eye Care Patients at Home: Method Comparison Study
    Claessens, Janneau
    van Egmond, Juultje
    Wanten, Joukje
    Bauer, Noel
    Nuijts, Rudy
    Wisse, Robert
    [J]. JMIR FORMATIVE RESEARCH, 2023, 7
  • [7] FuSpot: a web-based tool for visual evaluation of fusion candidates
    Jackson A. Killian
    Taha M. Topiwala
    Alex R. Pelletier
    David E. Frankhouser
    Pearlly S. Yan
    Ralf Bundschuh
    [J]. BMC Genomics, 19
  • [8] FuSpot: a web-based tool for visual evaluation of fusion candidates
    Killian, Jackson A.
    Topiwala, Taha M.
    Pelletier, Alex R.
    Frankhouser, David E.
    Yan, Pearlly S.
    Bundschuh, Ralf
    [J]. BMC GENOMICS, 2018, 19
  • [9] Construction and evaluation of an artificial neural network based screening tool for keratoconus using refractive error measurements
    Quah, Xhian M.
    Kerdraon, Yves
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 49 (08): : 862 - 863
  • [10] Prevalence of Visual Impairment and Uncorrected Refractive Error - Report from a Canadian Urban Population-based Study
    Robinson, Barbara
    Feng, Yunwei
    Woods, Craig A.
    Fonn, Desmond
    Gold, Deborah
    Gordon, Keith
    [J]. OPHTHALMIC EPIDEMIOLOGY, 2013, 20 (03) : 123 - 130