Development of a virtual source model for Monte Carlo-based independent dose calculation for varian linac

被引:2
|
作者
Castle, James R. [1 ]
Duan, Jingwei [2 ]
Feng, Xue [1 ]
Chen, Quan [2 ]
机构
[1] Carina Med LLC, 145 Graham Ave,A168, Lexington, KY 40506 USA
[2] Univ Kentucky, Dept Radiat Med, Sch Med, Lexington, KY USA
来源
关键词
Monte Carlo independent dose calculation; virtual source model; Varian Linac; CLINICAL IMPLEMENTATION; PHOTON BEAMS; SIMULATION; RADIOTHERAPY; ACCELERATOR;
D O I
10.1002/acm2.13556
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Monte Carlo (MC) independent dose calculations are often based on phase-space files (PSF), as they can accurately represent particle characteristics. PSF generally are large and create a bottleneck in computation time. In addition, the number of independent particles is limited by the PSF, preventing further reduction of statistical uncertainty. The purpose of this study is to develop and validate a virtual source model (VSM) to address these limitations. Particles from existing PSF for the Varian TrueBeam medical linear accelerator 6X, 6XFFF, 10X, and 10XFFF beam configurations were tallied, analyzed, and used to generate a dual-source photon VSM that includes electron contamination. The particle density distribution, kinetic energy spectrum, particle direction, and the correlations between characteristics were computed. The VSM models for each beam configuration were validated with water phantom measurements as well as clinical test cases against the original PSF. The new VSM requires 67 MB of disk space for each beam configuration, compared to 50 GB for the PSF from which they are based and effectively remove the bottleneck set by the PSF. At 3% MC uncertainty, the VSM approach reduces the calculation time by a factor of 14 on our server. MC doses obtained using the VSM approach were compared against PSF-generated doses in clinical test cases and measurements in a water phantom using a gamma index analysis. For all tests, the VSMs were in excellent agreement with PSF doses and measurements (>90% passing voxels between doses and measurements). Results of this study indicate the successful derivation and implementation of a VSM model for Varian Linac that significantly saves computation time without sacrificing accuracy for independent dose calculation.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Development of a Virtual Source Model for Monte Carlo Based Independent Dose Calculation for Varian Linac
    Castle, J.
    Feng, X.
    Chen, Q.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [2] Cloud Based Monte Carlo Independent Dose Calculation Tool for Varian Linac: Implementation and Validation
    Chen, Q.
    Oldland, T.
    Sanford, L.
    Johnson, E.
    Molloy, J.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E278 - E278
  • [3] Verification of a Monte Carlo-Based Source Model for a Varian 10 MV Photon Beam
    Davidson, S.
    Cui, J.
    Deasy, J.
    Ibbott, G.
    Followill, D.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [4] Fast Monte Carlo Dose Calculation Tool for Varian Halcyon Using Virtual Source Models
    Castle, J.
    Chen, Q.
    Feng, X.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E265 - E265
  • [5] Virtual source modelling in Monte Carlo-based clinical dose calculations: Methods and issues associated with their development and use
    Chetty, I.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S38 - S39
  • [6] Commissioning of the virtual source model for use in a Monte Carlo dose calculation for dose QA
    Napolitano, M.
    Krivosheev, O.
    Pencea, S.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2427 - 2427
  • [7] Monte Carlo-based dose calculation for (32) P patch source for superficial brachytherapy applications
    Sahoo, Sridhar
    Palani, Selvam T.
    Saxena, S. K.
    Babu, D. A. R.
    Dash, A.
    [J]. JOURNAL OF MEDICAL PHYSICS, 2015, 40 (01) : 13 - 17
  • [8] Validation of a virtual source model for Monte Carlo dose calculations of a flattening filter free linac
    Cashmore, Jason
    Golubev, Sergey
    Dumont, Jose Luis
    Sikora, Marcin
    Alber, Markus
    Ramtohul, Mark
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3262 - 3269
  • [9] Experimental verification of a Monte Carlo-based MLC simulation model for IMRT dose calculation
    Tyagi, Neelam
    Moran, Jean M.
    Litzenberg, Dale W.
    Bielajew, Alex F.
    Fraass, Benedick A.
    Chetty, Indrin J.
    [J]. MEDICAL PHYSICS, 2007, 34 (02) : 651 - 663
  • [10] Monte Carlo-based dose calculation engine for minibeam radiation therapy
    Martinez-Rovira, I.
    Sempau, J.
    Prezado, Y.