Development of a biosensor for gaseous cyanide in solution

被引:17
|
作者
Lee, JI [1 ]
Karube, I [1 ]
机构
[1] UNIV TOKYO,ADV SCI & TECHNOL RES CTR,MEGURO KU,TOKYO 153,JAPAN
来源
BIOSENSORS & BIOELECTRONICS | 1996年 / 11卷 / 11期
关键词
gas-phase biosensor; microbial electrode; P-fluorescens NCIMB 11764; cyanide; environmental monitoring;
D O I
10.1016/0956-5663(96)82337-2
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A gas-phase biosensor was developed using cyanide degrading bacteria, an oxygen electrode and a gas permeable PTFE membrane; Cyanide degrading bacteria, Pseudomonas fluorescens NCIMB 11764, consume oxygen upon degradation of cyanide. A change in oxygen concentration was detected using a Clark oxygen electrode. A linear relationship was observed between the current decrease and the cyanide ion concentration in the range 0.1-1 mg/l. The optimum working conditions of the sensor were pH 2 and 30 degrees C. The sensor was unaffected by heavy-metal ions and biochemical oxygen demand (glucose, glutamic acid). A good correlation was found between results obtained with the biosensor and those obtained using the Japanese Industrial Standard (JIS) method. The correlation coefficient was 0.995. When the biosensor was stored at 4 degrees C, but operated at 30 degrees C, the sensor was stable for up to 1 month. (C) 1996 Elsevier Science Limited
引用
收藏
页码:1147 / 1154
页数:8
相关论文
共 50 条
  • [1] Development of a biosensor for gaseous cyanide in solution
    Res. Ctr. for Adv. Sci. and Technol., University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153, Japan
    BIOSENS. BIOELECTRON., 11 (1147-1154):
  • [2] Amperometric inhibition biosensor for the determination of cyanide
    Ghanavati, Mahdi
    Azad, Reza Roosta
    Mousavi, Seyyed Abbas
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 190 : 858 - 864
  • [3] Development of a sol-gel enzyme inhibition-based amperometric biosensor for cyanide
    Park, TM
    Iwuoha, EI
    Smyth, MR
    ELECTROANALYSIS, 1997, 9 (14) : 1120 - 1123
  • [4] Development of a Sol-Gel Enzyme Inhibition-Based Amperometric Biosensor for Cyanide
    BEST Centre, School of Chemical Sciences, Dublin City University, Dublin 9, Ireland
    不详
    Electroanalysis, 14 (1120-1123):
  • [5] A FLOW THROUGH ANALYSIS BIOSENSOR SYSTEM FOR CYANIDE
    GROOM, CA
    LUONG, JHT
    JOURNAL OF BIOTECHNOLOGY, 1991, 21 (1-2) : 161 - 172
  • [6] Hydroxyapatite nanoarray-based cyanide biosensor
    Wang, Suiping
    Lei, Yong
    Zhang, Yun
    Tang, Jian
    Shen, Guoli
    Yu, Ruqin
    ANALYTICAL BIOCHEMISTRY, 2010, 398 (02) : 191 - 197
  • [7] Development and electrochemical investigations of an EIS( electrolyte-insulator-semiconductor) based biosensor for cyanide detection
    Turek, Monika
    Ketterer, Lothar
    Classen, Melanie
    Berndt, Heinz K.
    Elbers, Gereon
    Krueger, Peter
    Keusgen, Michael
    Schoening, Michael J.
    SENSORS, 2007, 7 (08) : 1415 - 1426
  • [8] POLYMORPHIC TRANSITIONS IN CYANIDE CRYSTALS AND CALCULATION OF LATTICE ENERGIES OF CYANIDE SALTS - THERMODYNAMIC PARAMETERS FOR GASEOUS CYANIDE ION
    JENKINS, HDB
    PRATT, KF
    JOURNAL OF INORGANIC & NUCLEAR CHEMISTRY, 1976, 38 (10): : 1775 - 1781
  • [9] Anodic kinetics of cyanide ions in an copper cyanide solution
    Hwang, C.W.
    Wang, Y.Y.
    Wan, C.C.
    Journal of the Chinese Institute of Chemical Engineers, 1993, 24 (06):
  • [10] A new PANI biosensor based on catalase for cyanide determination
    Ozcan, Hakki Mevlut
    Aydin, Tuba
    ARTIFICIAL CELLS NANOMEDICINE AND BIOTECHNOLOGY, 2016, 44 (02) : 664 - 671