Correlation between high frequency intravascular ultrasound and histomorphology in human coronary arteries

被引:82
|
作者
Prati, F
Arbustini, E
Labellarte, A
Dal Bello, B
Sommariva, L
Mallus, MT
Pagano, A
Boccanelli, A
机构
[1] S Giovanni Hosp, Catheterisat Lab, I-00165 Rome, Italy
[2] Ist Anat Patol, Pavia, Italy
关键词
intracoronary ultrasound; atherosclerosis; plaque morphology;
D O I
10.1136/heart.85.5.567
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective-To test the efficacy of high frequency intravascular ultrasound (IVUS) transducers in identifying lipid/necrotic pools in atherosclerotic plaques. Methods-40 MHz transducers were used for in vitro IVUS assessment of 12 arterial segments (10 coronary and two carotid arteries, dissected from five different necropsy cases). IVUS acquisition was performed at 0.5 mm/s after ligature of the branching points to generate a closed system. Lipid/necrotic areas were defined by IVUS as large echolucent intraplaque areas surrounded by tissue with higher echodensity. To obtain histopathological sections corresponding to IVUS cross sections, vessels were divided into consecutive 3 mm long segments using the most distal recorded IVUS image as the starring reference. Samples were then fixed with 10% buffered formalin, processed for histopathological study, serially cut, and stained using the Movat pentacrome method. Results-122 sections were analysed. Lipid pools were observed by histology in 30 sections (25%). IVUS revealed the presence of lipid pools in 19 of these sections (16%; sensitivity 65%, specificity 95%). Conclusions-In vitro assessment of lipid/necrotic pools with high frequency transducers was achieved with good accuracy. This opens new perspectives for future IVUS characterisation of atherosclerotic plaques.
引用
收藏
页码:567 / 570
页数:4
相关论文
共 50 条
  • [1] Intravascular Ultrasound in the Coronary Arteries
    McKay, Charles R.
    Shavelle, David M.
    [J]. SEMINARS IN VASCULAR SURGERY, 2006, 19 (03) : 132 - 138
  • [2] Discrepancy between frequency domain optical coherence tomography and intravascular ultrasound in human coronary arteries and in a phantom in vitro coronary model
    Kim, In-Cheol
    Nam, Chang-Wook
    Cho, Yun-Kyeong
    Park, Hyoung-Seob
    Yoon, Hyuck-Jun
    Kim, Hyungseop
    Chung, In-Sung
    Han, Seongwook
    Hur, Seung-Ho
    Kim, Yoon-Nyun
    Kim, Kwon-Bae
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 221 : 860 - 866
  • [3] Segmentation method of intravascular ultrasound images of human coronary arteries
    Destrempes, Francois
    Cardinal, Marie-Helene Roy
    Allard, Louise
    Tardif, Jean-Claude
    Cloutier, Guy
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2014, 38 (02) : 91 - 103
  • [4] Intravascular ultrasound for evaluation of coronary arteries
    Gorge, G
    Ge, J
    Haude, M
    Shah, V
    Jeremias, A
    Simon, H
    Erbel, R
    [J]. HERZ, 1996, 21 (02) : 78 - 89
  • [5] Comparison of longitudinal geometric measurement in human coronary arteries between frequency-domain optical coherence tomography and intravascular ultrasound
    Liu, Yong
    Shimamura, Kunihiro
    Kubo, Takashi
    Tanaka, Atsuhi
    Kitabata, Hironori
    Ino, Yasushi
    Tanimoto, Takashi
    Shiono, Yasutsugu
    Orii, Makoto
    Yamano, Takashi
    Yamaguchi, Tomoyuki
    Hirata, Kumiko
    Imanishi, Toshio
    Akasaka, Takashi
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (02): : 271 - 277
  • [6] Comparison of longitudinal geometric measurement in human coronary arteries between frequency-domain optical coherence tomography and intravascular ultrasound
    Yong Liu
    Kunihiro Shimamura
    Takashi Kubo
    Atsuhi Tanaka
    Hironori Kitabata
    Yasushi Ino
    Takashi Tanimoto
    Yasutsugu Shiono
    Makoto Orii
    Takashi Yamano
    Tomoyuki Yamaguchi
    Kumiko Hirata
    Toshio Imanishi
    Takashi Akasaka
    [J]. The International Journal of Cardiovascular Imaging, 2014, 30 : 271 - 277
  • [7] INTRAVASCULAR ULTRASOUND DETECTION OF LIPID POOLS IN HUMAN CORONARY-ARTERIES
    GIRO, EK
    CUENOUD, HF
    [J]. CIRCULATION, 1995, 92 (08) : 3116 - 3116
  • [8] INTRAVASCULAR ULTRASOUND IMAGING IN HUMAN PERIPHERAL AND CORONARY-ARTERIES INVIVO
    MORIUCHI, M
    SAITO, S
    HONYE, J
    TAMURA, Y
    HIBIYA, K
    MORIUCHI, R
    KAMATA, T
    TSUJI, M
    MIZUMURA, T
    MAHON, D
    MALLERY, JA
    TOBIS, JM
    [J]. JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1992, 56 (06): : 578 - 585
  • [9] Intravascular ultrasound imaging of human carotid arteries: Correlation with angiographic and histopathological findings
    Manninen, HI
    Rasanen, HT
    Vanninen, RL
    Berg, MH
    Hippelainen, M
    Yang, X
    [J]. RADIOLOGY, 1997, 205 : 398 - 398
  • [10] Discrepancy between angiography and intravascular ultrasound when analysing small coronary arteries
    Briguori, C
    Tobis, J
    Nishida, T
    Vaghetti, M
    Albiero, R
    Di Mario, C
    Colombo, A
    [J]. EUROPEAN HEART JOURNAL, 2002, 23 (03) : 247 - 254