A new measurement set-up for the identification of fibre reinforcement permeabilities of composite materials

被引:0
|
作者
Hoes, K [1 ]
Sol, H [1 ]
Luo, Y [1 ]
机构
[1] Free Univ Brussels, Dept MEMC, B-1050 Brussels, Belgium
关键词
D O I
暂无
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In today's market an increasing demand for high-quality fibre reinforced polymers (FRP's) can be noticed. Applications range from automobile, sports, marine, heavy-duty machinery to household applications. The interest for the RTM production technique has risen significantly over the past few years because of higher demands on finish quality, production volumes, cycle times and last but not least, environmental implications. RTM can comply with all of these demands. One disadvantage of the RTM-technique is that the moulds used are often a relatively high cost-factor in the process and thus mould design has gained an increasing interest. Mould manufacturers are encouraged to perform flow front simulations in order to avoid mould filling problems and to optimise processing parameters. Almost all of these flow front simulation programs are based on Darcy's law. This law describes the relation between the flow-front speed and the applied pressure gradient for the saturated flow of an incompressible, Newtonian fluid in a porous medium. The program hence requires the input of processing parameters like viscosity, fibre volume fraction, etc. The dynamic viscosity of the resin can be measured relatively easily by means of special viscometers. The permeability however is linked to the porosity of the reinforcement that in turn is a function of the applied closing pressure of the mould. A good knowledge of the permeability is necessary to make good predictions using the flow front simulation software. Performing good permeability measurements is a tedious task that requires a great deal of skill and experience of the experimenter. The test set-up that will be discussed in this paper proposes new, user-friendlier permeability measurement equipment that relies much less on the operator capabilities.
引用
收藏
页码:333 / 343
页数:11
相关论文
共 50 条
  • [1] New set-up for in-plane permeability measurement
    Liu, Qiang
    Parnas, Richard S.
    Giffard, Hermione S.
    COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2007, 38 (03) : 954 - 962
  • [2] A NEW SET-UP FOR RADIOCINEMATOGRAPHY
    CHARBON, GA
    GROOT, R
    WEYMAN, G
    ACTA PHYSIOLOGICA ET PHARMACOLOGICA NEERLANDICA, 1962, 11 (3-4): : 504 - &
  • [3] New Set-up ECL
    不详
    EUROPEAN COMPANY LAW, 2005, 2 (04): : 129 - 129
  • [4] New set-up for CNRE
    1600, Elsevier Science B.V., Amsterdam, Netherlands (26):
  • [5] GeoTh: An Experimental Laboratory Set-Up for the Measurement of the Thermal Conductivity of Granular Materials
    Rapti, Dimitra
    Marchetti, Andrea
    Andreotti, Mirco
    Neri, Ilaria
    Caputo, Riccardo
    SOIL SYSTEMS, 2022, 6 (04)
  • [6] PARAMETER IDENTIFICATION OF LUGRE FRICTION MODEL: EXPERIMENTAL SET-UP DESIGN AND MEASUREMENT
    Sun, Yun-Hsiang
    Chen, Tao
    Shafai, Cyrus
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2015, VOL 4A, 2016,
  • [7] New set-up for measurement of permeability properties of fibrous reinforcements for RTM
    Hoes, K
    Dinescu, D
    Sol, H
    Vanheule, M
    Parnas, RS
    Luo, YW
    Verpoest, I
    COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2002, 33 (07) : 959 - 969
  • [8] Test set-up for the Capacitive humidity measurement
    Mikuta, Reinhard
    Wennmacher, Christian
    Burte, Edmund P.
    TM-TECHNISCHES MESSEN, 2006, 73 (11) : 611 - 616
  • [9] Modelling and simulation of RDWG measurement set-up
    Ismail, Kamariah
    Awang, Zaiki
    2007 ASIA-PACIFIC CONFERENCE ON APPLIED ELECTROMAGNETICS, PROCEEDINGS, 2007, : 128 - 132
  • [10] Fiberised set-up for eye length measurement
    Podoleanu, AG
    Dobre, GM
    Webb, DJ
    Jackson, DA
    OPTICS COMMUNICATIONS, 1997, 137 (4-6) : 397 - 405