The detection of stage I ovarian cancer by three-dimensional sonography and power Doppler

被引:51
|
作者
Kurjak, A [1 ]
Kupesic, S [1 ]
Sparac, V [1 ]
Prka, M [1 ]
Bekavac, I [1 ]
机构
[1] Univ Zagreb, Sch Med, Dept Obstet & Gynecol, Sveti Duh Hosp, Zagreb 10000, Croatia
关键词
stage I ovarian cancer; three-dimensional sonography; three-dimensional power Doppler; ovarian cancer screening;
D O I
10.1016/S0090-8258(03)00205-1
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective. The objective was to determine the diagnostic accuracy of three-dimensional (3D) sonography and 3D power Doppler imaging, used together with standard 2D transvaginal grayscale and color/power Doppler modalities, for preoperative sonographic assessment of suspected ovarian lesions. Methods. Five-year retrospective analysis was performed by our experts on ultrasonography and surgery on the reports from 43 referred patients with suspected stage I ovarian cancer. All patients were evaluated during the week prior to surgery at our department. Preoperative sonographic assessment included careful examination of ovarian volume, morphology, and vascularity by four complementary sonographic methods. Scoring systems combining morphological and Doppler parameters were adopted for 2D and 3D sonographic examinations. Final diagnosis was confirmed by a histopathologist. Results. Out of the 43 stage I ovarian cancers, 42 cases were successfully detected preoperatively by four complementary sonographic methods. Only 30 (69.8%) and 37 (86.1%) cases of stage I ovarian cancer were detected by 2D grayscale and combined 2D grayscale and color Doppler sonography, respectively. Morphological analysis obtained by 3D sonography alone detected 32 of 43 ovarian malignancies, reaching a diagnostic rate of 74.4%. Qualitative analysis of tumor vascularity architecture by 3D power Doppler significantly improved the sonographic management process and successfully detected 41 cases of stage I ovarian cancer (95.4%). When morphological features obtained by 3D sonography were added to 3D power Doppler findings, we achieved an even higher diagnostic accuracy of 97.7%. We found a statistically significant difference (P less than or equal to 0.01) in diagnostic rates of 3D power Doppler, and especially the combined use of 3D sonography and 3D power Doppler in comparison to those obtained with transvaginal 2D grayscale (P less than or equal to 0.002 and P less than or equal to 0.001, respectively) or 3D sonography (P less than or equal to 0.006 and P less than or equal to 0.002, respectively). Conclusions. In comparison to transvaginal 2D grayscale or 3D sonography, 3D power Doppler and especially the combined use of 3D sonography and power Doppler imaging significantly improve diagnostic accuracy in preoperative sonographic assessment of suspected ovarian lesions. (C) 2003 Elsevier Science (USA). All rights reserved.
引用
收藏
页码:258 / 264
页数:7
相关论文
共 50 条
  • [1] Three-dimensional power Doppler sonography of tumor vascularity
    Department of Oncoradiology, Nara Medical University, Kashihara-city, Nara, Japan
    不详
    不详
    不详
    J. Ultrasound Med., 10 (619-622):
  • [2] Three-dimensional power Doppler sonography of tumor vascularity
    Ohishi, H
    Hirai, T
    Yamada, R
    Hirohashi, S
    Uchida, H
    Hashimoto, H
    Jibiki, T
    Takeuchi, Y
    JOURNAL OF ULTRASOUND IN MEDICINE, 1998, 17 (10) : 619 - 622
  • [3] Three-dimensional power Doppler in ovarian tumors
    Alcazar, J. L.
    Guerriero, S.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2007, 29 (06) : 718 - 719
  • [4] Three-dimensional ultrasound and three-dimensional power Doppler in the assessment of ovarian tumors
    Laban, M.
    Metawee, H.
    Elyan, A.
    Kamal, M.
    Kamel, M.
    Mansour, G.
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2007, 99 (03) : 201 - 205
  • [5] Three-dimensional power Doppler in the diagnosis of ovarian torsion
    Yaman, C
    Ebner, T
    Jesacher, K
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2002, 20 (05) : 513 - 515
  • [6] Three-dimensional power Doppler ultrasound in ovarian cancer and its correlation with histology
    Iris Ohel
    Eyal Sheiner
    Barak Aricha-Tamir
    Benjamin Piura
    Mihai Meirovitz
    Tali Silberstein
    Reli Hershkovitz
    Archives of Gynecology and Obstetrics, 2010, 281 : 919 - 925
  • [7] Three-dimensional power Doppler ultrasound in ovarian cancer and its correlation with histology
    Ohel, Iris
    Sheiner, Eyal
    Aricha-Tamir, Barak
    Piura, Benjamin
    Meirovitz, Mihai
    Silberstein, Tali
    Hershkovitz, Reli
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2010, 281 (05) : 919 - 925
  • [8] Endometrial hyperplasia: three-dimensional power doppler sonography and dydrogesteron using
    Lysenka, V.
    GIORNALE ITALIANO DI OSTETRICIA E GINECOLOGIA, 2014, 36 (01): : 205 - 209
  • [9] Three-dimensional power Doppler sonography in screening for carotid artery disease
    Keberle, M
    Jenett, M
    Beissert, M
    Jahns, R
    Haerten, R
    Hahn, D
    JOURNAL OF CLINICAL ULTRASOUND, 2000, 28 (09) : 441 - 451
  • [10] Three-dimensional power Doppler sonography in the diagnosis of arteriovenous malformation of the uterus
    Ghi, T
    Giunchi, S
    Rossi, C
    Pilu, G
    Savelli, L
    Mollo, F
    Pelusi, G
    JOURNAL OF ULTRASOUND IN MEDICINE, 2005, 24 (05) : 727 - 731