Cranial fixation plates in cerebral magnetic resonance imaging: a 3 and 7 Tesla in vivo image quality study

被引:18
|
作者
Chen, Bixia [1 ,2 ]
Schoemberg, Tobias [1 ,2 ]
Kraff, Oliver [1 ]
Dammann, Philipp [1 ,2 ]
Bitz, Andreas K. [1 ,3 ]
Schlamann, Marc [4 ,5 ]
Quick, Harald H. [1 ,6 ]
Ladd, Mark E. [1 ,3 ]
Sure, Ulrich [2 ]
Wrede, Karsten H. [1 ,2 ]
机构
[1] Univ Duisburg Essen, Erwin L Hahn Inst Magnet Resonance Imaging, Essen, Germany
[2] Univ Hosp Essen, Dept Neurosurg, Essen, Germany
[3] German Canc Res Ctr, Med Phys Radiol, Heidelberg, Germany
[4] Univ Hosp Essen, Inst Diagnost & Intervent Radiol & Neuroradiol, Essen, Germany
[5] Univ Hosp Giessen, Dept Neuroradiol, Giessen, Germany
[6] Univ Hosp Essen, High Field & Hybrid MR Imaging, Essen, Germany
关键词
Magnetic resonance imaging; 7; Tesla; Titanium cranial fixation plates; Postoperative; Craniotomy; NEUROSURGICAL IMPLANTS; MRI;
D O I
10.1007/s10334-016-0548-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study assesses and quantifies impairment of postoperative magnetic resonance imaging (MRI) at 7 Tesla (T) after implantation of titanium cranial fixation plates (CFPs) for neurosurgical bone flap fixation. The study group comprised five patients who were intra-individually examined with 3 and 7 T MRI preoperatively and postoperatively (within 72 h/3 months) after implantation of CFPs. Acquired sequences included T-1-weighted magnetization-prepared rapid-acquisition gradient-echo (MPRAGE), T-2-weighted turbo-spin-echo (TSE) imaging, and susceptibility-weighted imaging (SWI). Two experienced neurosurgeons and a neuroradiologist rated image quality and the presence of artifacts in consensus reading. Minor artifacts occurred around the CFPs in MPRAGE and T-2 TSE at both field strengths, with no significant differences between 3 and 7 T. In SWI, artifacts were accentuated in the early postoperative scans at both field strengths due to intracranial air and hemorrhagic remnants. After resorption, the brain tissue directly adjacent to skull bone could still be assessed. Image quality after 3 months was equal to the preoperative examinations at 3 and 7 T. Image quality after CFP implantation was not significantly impaired in 7 T MRI, and artifacts were comparable to those in 3 T MRI.
引用
收藏
页码:389 / 398
页数:10
相关论文
共 50 条
  • [1] Cranial fixation plates in cerebral magnetic resonance imaging: a 3 and 7 Tesla in vivo image quality study
    Bixia Chen
    Tobias Schoemberg
    Oliver Kraff
    Philipp Dammann
    Andreas K. Bitz
    Marc Schlamann
    Harald H. Quick
    Mark E. Ladd
    Ulrich Sure
    Karsten H. Wrede
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2016, 29 : 389 - 398
  • [2] Magnetic Resonance Imaging of Cranial Nerves at 7 Tesla
    A. E. Grams
    O. Kraff
    J. Kalkmann
    S. Orzada
    S. Maderwald
    M. E. Ladd
    M. Forsting
    E. R. Gizewski
    Clinical Neuroradiology, 2013, 23 : 17 - 23
  • [3] Magnetic Resonance Imaging of Cranial Nerves at 7 Tesla
    Grams, A. E.
    Kraff, O.
    Kalkmann, J.
    Orzada, S.
    Maderwald, S.
    Ladd, M. E.
    Forsting, M.
    Gizewski, E. R.
    CLINICAL NEURORADIOLOGY, 2013, 23 (01) : 17 - 23
  • [4] In-vivo Magnetic Resonance Imaging of the Prostate at 7 Tesla
    Sammet, S.
    Jia, G.
    Koch, R. M.
    Schmalbrock, P.
    Knopp, M., V
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05)
  • [5] Cardiac Magnetic Resonance Imaging at 7 Tesla
    Stab, Daniel
    Al Najjar, Aiman
    O'Brien, Kieran
    Strugnell, Wendy
    Richer, Jonathan
    Rieger, Jan
    Niendorf, Thoralf
    Barth, Markus
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2019, (143):
  • [6] Image Restoration and Spatial Resolution in 7-Tesla Magnetic Resonance Imaging
    Lohmann, Gabriele
    Bohn, Stefan
    Mueller, Karsten
    Trampel, Robert
    Turner, Robert
    MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (01) : 15 - 22
  • [7] Diagnosis of cerebral ventriculomegaly in felines using 0.25 Tesla and 3 Tesla magnetic resonance imaging
    Przyborowska, P.
    Adamiak, Z.
    Holak, P.
    Zhalniarovich, Y.
    Maksymowicz, W. S.
    VETERINARNI MEDICINA, 2018, 63 (01) : 28 - 35
  • [8] 3 Tesla Magnetic Resonance Imaging
    Cuzino, Dragos
    Codorean, Ioan
    ROMANIAN JOURNAL OF MILITARY MEDICINE, 2010, 113 (01) : 14 - 17
  • [9] Image quality and cancer visibility of T2-weighted Magnetic Resonance Imaging of the prostate at 7 Tesla
    E. K. Vos
    M. W. Lagemaat
    J. O. Barentsz
    J. J. Fütterer
    P. Zámecnik
    H. Roozen
    S. Orzada
    A. K. Bitz
    M. C. Maas
    T. W. J. Scheenen
    European Radiology, 2014, 24 : 1950 - 1958
  • [10] Image quality and cancer visibility of T2-weighted Magnetic Resonance Imaging of the prostate at 7 Tesla
    Vos, E. K.
    Lagemaat, M. W.
    Barentsz, J. O.
    Fuetterer, J. J.
    Zamecnik, P.
    Roozen, H.
    Orzada, S.
    Bitz, A. K.
    Maas, M. C.
    Scheenen, T. W. J.
    EUROPEAN RADIOLOGY, 2014, 24 (08) : 1950 - 1958