Influence of scattered radiation on Gafchromic EBT3

被引:0
|
作者
Gotanda, T. [1 ]
Katsuda, T. [2 ]
Kawasaki, A. [3 ]
Gotanda, R. [1 ]
Akagawa, T. [4 ]
Kuwano, T. [5 ]
Tanki, N. [2 ]
Kawaji, Y. [6 ]
Shimono, T. [6 ]
Yamamoto, K. [7 ]
Yabunaka, K. [8 ]
机构
[1] Kawasaki Univ Med Welf, Fac Hlth Sci & Technol, Okayama, Japan
[2] Butsuryo Coll Osaka, Fac Hlth Sci, Osaka, Japan
[3] Natl Hosp Org Kyushu Med Ctr, Div Radiol Technol, Fukuoka, Fukuoka, Japan
[4] Tokushima Red Cross Hosp, Dept Radiol Technol, Tokushima, Japan
[5] Okayama Univ, Grad Sch Hlth Sci, Okayama, Japan
[6] Junshin Gakuen Univ, Fac Hlth Sci, Fukuoka, Fukuoka, Japan
[7] Osaka Ctr Canc & Cardiovasc Dis Prevent, Dept Radiol, Osaka, Japan
[8] Univ Tokyo, Grad Sch Med, Bunkyou Ku, Tokyo, Japan
来源
EMBEC & NBC 2017 | 2018年 / 65卷
关键词
Radiochromic film; Gafchromic EBT3; scattered radiation; RADIOCHROMIC FILM; PHANTOM; ENERGY;
D O I
10.1007/978-981-10-5122-7_259
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Gafchromic EBT3 (EBT3) is used as a radio chromic film in half-value layer (HVL) measurement methods, which are used to calculate the effective energy for QA and QC. HVL measurements using EBT3 display a precision of less than 5 % compared with the results of standard method with an ionization chamber (IC) dosimeter, and offer a simple procedure for determining the HVL consistently and quickly without the need for an IC. However, it is difficult to apply this technique because of the scattered radiation caused by the geometric layout of the X-ray computed tomography (CT) apparatus. In this study, the effect of scattered radiation on EBT3 is investigated. It was found that the EBT3 is not affected by scattered radiation at positions beyond 50 mm from the scattering substance. Therefore, the results suggest that EBT3 is suitable for use in Xray CT HVL measurements. On the other hand, when the distance from the scattering substance was 10 mm or less, EBT3 showed very high absorption compared to a semiconductor detector. Therefore, EBT3 is more sensitive than the semiconductor detector at a close range and can be used to measure scattered radiation when the distance from the scattering substance is 10 mm or less.
引用
收藏
页码:1037 / 1040
页数:4
相关论文
共 50 条
  • [1] Characterization of Gafchromic EBT3 films for ultraviolet radiation dosimetry
    Aydarous, Abdulkadir
    Al-Omary, Enaam Ali
    El Ghazaly, Mahmoud
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2014, 169 (03): : 249 - 255
  • [2] UNLAMINATED GAFCHROMIC EBT3 FILM FOR ULTRAVIOLET RADIATION MONITORING
    Welch, David
    Randers-Pehrson, Gerhard
    Spotnitz, Henry M.
    Brenner, David J.
    RADIATION PROTECTION DOSIMETRY, 2017, 176 (04) : 341 - 346
  • [3] A diffuse reflectance spectrophotometer for radiation dosimetry of EBT3 GAFchromic films
    Piliero, Maria A.
    Pupillo, Francesco
    Presilla, Stefano
    Radiation Measurements, 2022, 154
  • [4] Responses of Gafchromic EBT3 films with polypropylene barriers to UV radiation
    Yu, K. N.
    Chun, S. L.
    Chan, P. M.
    RESULTS IN PHYSICS, 2017, 7 : 1976 - 1977
  • [5] A diffuse reflectance spectrophotometer for radiation dosimetry of EBT3 GAFchromic films
    Piliero, Maria A.
    Pupillo, Francesco
    Presilla, Stefano
    RADIATION MEASUREMENTS, 2022, 154
  • [6] Polarized dosimetry method for Gafchromic EBT3
    Perez Azorin, Jose Fernando
    Ramos Garcia, Luis Isaac
    Maza Ozcoidi, Diego
    Almansa, Julio F.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (08): : 972 - 980
  • [7] Correction of nonuniformity error of Gafchromic EBT2 and EBT3
    Katsuda, Toshizo
    Gotanda, Rumi
    Gotanda, Tatsuhiro
    Akagawa, Takuya
    Tanki, Nobuyoshi
    Kuwano, Tadao
    Yabunaka, Kouichi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (03): : 41 - 51
  • [8] Absolute dose calibration of EBT3 Gafchromic films
    Campajola, L.
    Casolaro, P.
    Di Capua, F.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [9] Energy response of the GAFCHROMIC EBT3 in diagnosis range
    Gotanda, T.
    Katsuda, T.
    Gotanda, R.
    Kuwano, T.
    Akagawa, T.
    Tanki, N.
    Tabuchi, A.
    Shimono, T.
    Kawaji, Y.
    Ideguchi, T.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 752 - 755
  • [10] Calibrating page sized Gafchromic EBT3 films
    Crijns, W.
    Maes, F.
    van der Heide, U. A.
    Van den Heuvel, F.
    MEDICAL PHYSICS, 2013, 40 (01)