Measuring sit-to-stand timing variability over time using under mattress pressure sensor technology

被引:0
|
作者
Grant, Theresa [1 ,2 ]
Joshi, Vilas [3 ]
Taylor, Matthew [3 ]
Knoefel, Frank [1 ,2 ,3 ]
Sveistrup, Heidi
Bilodeau, Martin [1 ,2 ]
Jutai, Jeffrey [1 ,4 ]
机构
[1] Bruyere Res Inst, Bruyere Continuing Care, Ottawa, ON, Canada
[2] Univ Ottawa, Sch Rehabil Sci, Ottawa, ON, Canada
[3] Carleton Univ, Dept Syst & Comp Engn, Ottawa, ON, Canada
[4] Univ Ottawa, Interdisciplinary Sch Hlth Sci, Ottawa, ON, Canada
基金
加拿大健康研究院; 加拿大自然科学与工程研究理事会;
关键词
pressure sensors; patient monitoring; bed exit; sit-to-stand; variability; home context;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Getting out of bed is a fundamental activity of daily living and one that supports independent living. Under mattress pressure sensor technology represents a way to monitor changes in this basic but critical mobility task among older adults at risk of institutionalization. However, little is known about normal variations in this ability over time in the home context. This study used under mattress pressure sensors to measure and analyze the variability of sit-to-stand (STS) timing in a community-dwelling older adult. A pressure-sensitive mat was installed in the participant's home and left in place to collect information over a period of nine months. A processing algorithm was developed to extract the STS phase of the first morning bed exit from which STS time could be measured. STS timing data were visualized using a histogram and analyzed for trends over the extended period using nonparametric regression and wavelet analysis. Results indicate that the analytical methods used were able to identify trends in STS timing as well as highlight deviations. The ability to collect and analyze the variability of STS timing using this pressure sensitive technology combined with the analysis methodology provides clinicians with a way to assess mobility remotely in the home setting.
引用
收藏
页码:335 / 339
页数:5
相关论文
共 31 条
  • [1] Sit-to-stand Timing Measurements Using Pressure Sensitive Technology
    Veledar, I.
    Arcelus, A.
    Goubran, R.
    Knoefel, F.
    Sveistrup, H.
    Bilodeau, M.
    2010 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE I2MTC 2010, PROCEEDINGS, 2010,
  • [2] Measurements of Sit-to-Stand Timing and Symmetry From Bed Pressure Sensors
    Arcelus, Amaya
    Veledar, Idana
    Goubran, Rafik
    Knoefel, Frank
    Sveistrup, Heidi
    Bilodeau, Martin
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2011, 60 (05) : 1732 - 1740
  • [3] Time measurement characterization of stand-to-sit and sit-to-stand transitions by using a smartphone
    Hernán A. González Rojas
    Pedro Chaná Cuevas
    Enrique E. Zayas Figueras
    Salvador Cardona Foix
    Antonio J. Sánchez Egea
    Medical & Biological Engineering & Computing, 2018, 56 : 879 - 888
  • [4] Time measurement characterization of stand-to-sit and sit-to-stand transitions by using a smartphone
    Gonzalez Rojas, Hernan A.
    Chana Cuevas, Pedro
    Zayas Figueras, Enrique E.
    Cardona Foix, Salvador
    Sanchez Egea, Antonio J.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2018, 56 (05) : 879 - 888
  • [5] Evaluation of sit-to-stand motion using a pressure distribution measurement system - effect of differences in seat hardness on sit-to-stand motion
    Sato, Shinsuke
    Mizuma, Masazumi
    Kawate, Nobuyuki
    Kasai, Fumihito
    Watanabe, Hideyasu
    DISABILITY AND REHABILITATION-ASSISTIVE TECHNOLOGY, 2011, 6 (04) : 290 - 298
  • [6] Development of a sit-to-stand assistive device with pressure sensor for elderly and disabled: a feasibility test
    Lee, Kyeongbong
    Ha, SinHo
    Lee, Kwangkook
    Hong, SoungKyun
    Shin, HyeonHui
    Lee, GyuChang
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2021, 44 (03) : 677 - 682
  • [7] Development of a sit-to-stand assistive device with pressure sensor for elderly and disabled: a feasibility test
    Kyeongbong Lee
    SinHo Ha
    Kwangkook Lee
    SoungKyun Hong
    HyeonHui Shin
    GyuChang Lee
    Physical and Engineering Sciences in Medicine, 2021, 44 : 677 - 682
  • [8] Measuring Left Ventricular Ejection Time using Under-the-Mattress Sensor
    Sela, Itamar
    Shinar, Zvika
    Tavakolian, Kouhyar
    2016 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), VOL 43, 2016, 43 : 665 - 668
  • [9] Determination of Sit-to-Stand Transfer Duration Using Bed and Floor Pressure Sequences
    Arcelus, Amaya
    Herry, Christophe L.
    Goubran, Rafik A.
    Knoefel, Frank
    Sveistrup, Heidi
    Bilodeau, Martin
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2009, 56 (10) : 2485 - 2492
  • [10] Distinguishing Between Stable and Unstable Sit-To-Stand Transfers Using Pressure Sensors
    Bennett, S. L.
    Goubran, R.
    Rockwood, K.
    Knoefel, F.
    2014 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2014, : 76 - 79