摘要
A very low jitter trigger is required for the Main Injector Proton Injection kicker. The trigger is also designed to be reliable against thyratron are down to the trigger grid. The trigger uses a wide band coaxial cable transformer that operates at 1500 V with a 500 ns purse width and a 10% -90% rise time of 20 ns. An FET is used as the switch and a very low inductance capacitor is used to store the trigger energy. Typical total jitter between TTL trigger pulse and the 50% load current value has been measured at < 2 ns over a period of 8 hours and 10(5) pulses. About half this jitter is attributed to the trigger system, and the other half to the thyratron. The trigger has been subjected to several thyratron sparks without problem. The paper will present the trigger schematic, waveforms, components and the thyratron connections.
引用
收藏
页码:1281 / 1283
页数:3
相关论文
共 50 条
  • [1] Thyratron trigger with low jitter
    FNAL, Batavia, United States
    Proc IEEE Part Accel Conf, (1281-1283):
  • [2] High performance thyratron driver with low jitter
    Verma, Rishi
    Lee, P.
    Springham, S. V.
    Tan, T. L.
    Rawat, R. S.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (08):
  • [3] THYRATRON GRID EMISSION AND THE TRIGGER-GRID THYRATRON
    MALTER, L
    BOYD, MR
    PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1950, 38 (02): : 205 - 205
  • [4] Design of Driving Power Supplies for Improvement of Thyratron Jitter Characteristic
    Kim, Tae-Hyun
    Kim, Shin
    Bae, Jung-Soo
    Son, Seong-Ho
    Kwon, Chang-Hyun
    Yu, Chan-Hun
    Kim, Hyoung-Suk
    Jang, Sung-Roc
    Ahn, Suk-Ho
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2023, 51 (10) : 2797 - 2804
  • [5] Low-current hollow-cathode discharge in a trigger unit of a cold cathode thyratron
    Landl, N. V.
    Korolev, Y. D.
    Frants, O. B.
    Geyman, V. G.
    Bolotov, A. V.
    12TH INTERNATIONAL CONFERENCE ON GAS DISCHARGE PLASMAS AND THEIR APPLICATIONS, 2015, 652
  • [6] Low jitter trigger circuit and wide band amplifier of fast electronics
    China Inst of Atomic Energy, Beijing, China
    Yuanzineng Kexue Jishu, 4 (372-376):
  • [7] A DIGITIZING OSCILLOSCOPE TIME BASE AND TRIGGER SYSTEM OPTIMIZED FOR THROUGHPUT AND LOW JITTER
    ESKELDSON, DD
    KELLUM, R
    WHITEMAN, DA
    HEWLETT-PACKARD JOURNAL, 1993, 44 (05): : 24 - 30
  • [8] Design of 5 kHz repetition-rate trigger for hydrogen thyratron
    Wu, H. (wumario@163.com), 1600, Editorial Office of High Power Laser and Particle Beams (26):
  • [9] A novel trigger for pseudospark switch with high repetition rate, low jitter, and compact structure
    Yan, Jiaqi
    Shen, Saikang
    Wang, Yanan
    Zhang, Siyu
    Cheng, Le
    Ding, Weidong
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (06):
  • [10] Development of low jitter fast fall time and repetitive high voltage pulsed trigger
    Cao, Ningxiang, 1600, Editorial Office of High Power Laser and Particle Beams (26):