Digital Autoradiography imaging using CMOS technology: First Tritium Autoradiography with a back-thinned CMOS detector and comparison of CMOS imaging performance with autoradiography film

被引:0
|
作者
Cabello, J. [1 ]
Wells, K. [1 ]
Metaxas, A. [2 ]
Bailey, A. [2 ]
Kitchen, I. [2 ]
Clark, A. [3 ]
Prydderch, A. [3 ]
Turchetta, R. [3 ]
机构
[1] Univ Surrey, Fac Engn & Phys Sci, Ctr Vis Speech & Signal Proc, Guildford GU2 7XH, Surrey, England
[2] Univ Surrey, Fac Hlth & Med Sci, Pharmacol Grp, Guildford GU2 7XH, Surrey, England
[3] Rutherford Appleton Lab, Dept Technol, Sci & Technol Facil, Didcot OX110QX, Oxon, England
关键词
Digital Autoradiography; Tritium Autoradiography; CMOS technology; back-thinned technology;
D O I
10.1109/NSSMIC.2007.4436936
中图分类号
O59 [应用物理学];
学科分类号
摘要
It has been shown that CMOS imaging technology can be applied to Digital Autoradiography (AR) as a potential imaging alternative technology to using conventional film emulsion. In this work a thorough investigation on the performance of CMOS technology used in AR is presented. H-3 is a particularly important radioisotope used in AR because it can label many sites on biomolecules and provides the highest resolution images due to its low energy and hence low particle range compared to other beta-emitting radioisotopes. In order to detect 3-particles from H-3 beta decay a back-thinned CMOS sensor has been used. Back-thinning is a standard process in CCDs but it is not widely applied to CMOS sensors. In this paper the first results of imaging a calibrated H-3 microscale and the first tritiated autoradiogram obtained with a back-thinned CMOS sensor at room temperature are presented.
引用
收藏
页码:3743 / +
页数:2
相关论文
共 9 条
  • [1] Digital autoradiography using CCD and CMOS imaging technology
    Cabello, J.
    Bailey, A.
    Kitchen, I.
    Clark, A.
    Crooks, J.
    Halsall, R.
    Key-Charriere, M.
    Martin, S.
    Prydderch, M.
    Turchetta, R.
    Wells, K.
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2607 - 2612
  • [2] Digital autoradiography using room temperature CCD and CMOS imaging technology
    Cabello, Jorge
    Bailey, Alexis
    Kitchen, Ian
    Prydderch, Mark
    Clark, Andy
    Turchetta, Renato
    Wells, Kevin
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (16): : 4993 - 5011
  • [3] 18F autoradiography using pixelated CMOS technology
    Truong Nguyen Pham
    Finck, Christian
    Marchand, Patrice
    Brasse, David
    Boisson, Frederic
    Laquerriere, Patrice
    [J]. 2017 IEEE 15TH INTERNATIONAL NEW CIRCUITS AND SYSTEMS CONFERENCE (NEWCAS), 2017, : 41 - 44
  • [4] CMOS and sCMOS imaging performance comparison by digital holographic interferometry
    Mauricio Flores-Moreno, Jorge
    De la Torre Ibarra, Manuel H.
    del Socorro Hernandez-Montes, Maria
    Perez Lopez, Carlos
    Mendoza Santoyo, Fernando
    [J]. OPTICAL ENGINEERING, 2016, 55 (12)
  • [5] Imaging Performance Analysis & Comparison between A High Sensitivity Low level light CMOS Detector and An EMCCD
    Bu Hongbo
    Wang Gengyun
    Zhai Guofang
    Li Yongqiang
    Li Haoyang
    [J]. ADVANCED SENSOR SYSTEMS AND APPLICATIONS VIII, 2018, 10821
  • [6] First principles' imaging performance evaluation of CCD- and CMOS-based digital camera systems
    Rodricks, B
    Venkataraman, K
    [J]. Digital Photography, 2005, 5678 : 59 - 74
  • [7] Imaging performance comparison between CMOS and sCMOS detectors in a vibration test on large areas using digital holographic interferometry
    Flores-Moreno, J. M.
    De la Torre, Manuel H., I
    Aguayo, Daniel D.
    Fernando Mendoza, S.
    [J]. 11TH INTERNATIONAL CONFERENCE ON VIBRATION MEASUREMENTS BY LASER AND NONCONTACT TECHNIQUES - AIVELA 2014: ADVANCES AND APPLICATIONS, 2014, 1600 : 223 - 227
  • [8] Comparison of diagnostic accuracy of digital imaging by using CCD and CMOS-APS sensors with E-speed film in the detection of periapical bony lesions
    Paurazas, SB
    Geist, JR
    Pink, FE
    Hoen, MM
    Steiman, HR
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2000, 89 (03): : 356 - 362
  • [9] Comparison of CCD and CMOS Micro-Angiographic Fluoroscope (MAF) Detector Systems Using Contrast Measurements for Specific Imaging Tasks Related to Neuro-Endovascular Image-Guided Interventional (EIGI) Procedures
    Rana, R.
    Jain, A.
    Nagesh, S. Setlur
    Bednarek, D.
    Rudin, S.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 133 - +