Femur Design Parameters and Contact Stresses at UHMWPE Hip Joint Cup

被引:0
|
作者
Fouad, H. [1 ,2 ]
Darwish, S. M. [3 ]
机构
[1] King Saud Univ, RCC, Dept Appl Sci Med, POB 28095-11437, Riyadh, Saudi Arabia
[2] Helwan Univ, Fac Engn, Helwan, Egypt
[3] King Saud Univ, Engn Coll, Dept Ind Engn, Riyadh 11421, Saudi Arabia
关键词
FE; femur; Cup Dimensions; UHMWPE; FGM; SS; Ti; CoCrMo; MOLECULAR-WEIGHT POLYETHYLENE; WEAR; REPLACEMENT; BEHAVIOR;
D O I
10.4028/www.scientific.net/KEM.478.93
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The contact stress that occurs in the ultra-high molecular weight polyethylene (UHMWPE) hip joint cup has been shown to be correlated with the implant wear rate. The wear of the hip joint is considered as one of the main factors that affect the long term performance of the implant. The contact stress that occurs in the UHMWPE hip joint cup is affected by the implant dimensions and materials. In this study, four different femur materials and geometries were used to investigate the effects of femur design parameters on the resultant contact stress on the UHMWPE cup. The results of the finite element (FE) simulation show that the contact stresses at the UHMWPE cup decreases dramatically with increasing the femur diameter. Also the results indicated that the contact stresses on the UHMWPE cup decrease significantly when using functionally graded (FG) femur with low modulus of elasticity. The presence of metal backing results in a slight reduction in the UHMWPE cup contact stresses especially for small femurs. Finally, the presence of a gap between the UHMWPE cup and the femur results in a remarkable increase in the cup stress especially for a small femur. The hip joint femur dimensions and materials are thought to play an important role in the transition of load in the implant and should be taken into consideration during the design of the hip joint.
引用
收藏
页码:93 / +
页数:3
相关论文
共 50 条
  • [1] CUP ARTHROPLASTY OF THE HIP JOINT
    NADEN, JR
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1948, 30 (01): : 220 - 221
  • [2] Wear Prediction of UHMWPE Acetabular Cup against CP Titanium Femoral Head in a Hip Joint Simulator
    Handoko, H.
    Suyitno, S.
    Dharmastiti, R.
    Magetsari, R.
    INTERNATIONAL SYMPOSIUM ON MATERIALS AND ELECTRICAL ENGINEERING (ISMEE) 2017, 2018, 384
  • [3] Comparison of methods to measure contact stresses in UHMWPE
    Blakemore, DM
    Levine, D
    PROCEEDINGS OF THE SEM IX INTERNATIONAL CONGRESS ON EXPERIMENTAL MECHANICS, 2000, : 575 - 576
  • [4] Wear and bending strain characteristics of artificial hip joint with non-glued stem and UHMWPE femur
    Ishida, K
    Okada, K
    Hamada, Y
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2005, 29 (04): : 396 - 403
  • [5] THE STRESSES IN THE FEMUR AFTER JOINT REPLACEMENT
    ROHLMANN, A
    MOSSNER, U
    BERGMANN, G
    HEES, G
    KOLBEL, R
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1983, 121 (01): : 47 - 57
  • [6] A method of calculation for contact pressure between femoral head and cup of artificial hip joint
    Imado, K
    Kido, Y
    Miyagawa, H
    TRIBOLOGY TRANSACTIONS, 2005, 48 (02) : 230 - 237
  • [7] Effect of head contact on the rim of the cup on the offset loading and torque in hip joint replacement
    Liu, Feng
    Williams, Sophie
    Jin, Zhongmin
    Fisher, John
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (11) : 1147 - 1154
  • [8] A new discrete element analysis method for predicting hip joint contact stresses
    Abraham, Christine L.
    Maas, Steve A.
    Weiss, Jeffrey A.
    Ellis, Benjamin J.
    Peters, Christopher L.
    Anderson, Andrew E.
    JOURNAL OF BIOMECHANICS, 2013, 46 (06) : 1121 - 1127
  • [9] Hip Joint Geometry Effects on Cartilage Contact Stresses during a Gait Cycle
    Wu, Hui-Hui
    Wang, Dong
    Ma, An-Bang
    Gu, Dong-Yun
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 6038 - 6041
  • [10] Limitations of artificial hip joint mobility due to wear and ceramic cup design
    Bader, R.
    Steinhauser, E.
    Willmann, G.
    Gradinger, R.
    Key Engineering Materials, 2001, 192-195 : 549 - 552