Peritoneal transport characteristics with glycerol-based dialysate in peritoneal dialysis

被引:0
|
作者
Smit, W
de Waart, DR
Struijk, DG
Krediet, RT
机构
[1] Acad Med Ctr, Dept Nephrol, Amsterdam, Netherlands
[2] Acad Med Ctr, Dept Clin Chem, Amsterdam, Netherlands
来源
PERITONEAL DIALYSIS INTERNATIONAL | 2000年 / 20卷 / 05期
关键词
transport characteristics; glycerol; reflection coefficients; restriction coefficients;
D O I
暂无
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
* Background: Glycerol is a low molecular weight solute (MW 92 D) that can be used as an osmotic agent in continuous ambulatory peritoneal dialysis (CAPD). Due to its low molecular weight, the osmotic gradient disappears rapidly. Despite the higher osmolality at the beginning of a dwell, ultrafiltration has been found to be lower for glycerol compared to glucose (MW 180 D) when equimolar concentrations are used. Previous studies have shown glycerol to be safe for long-term use, but some discrepancies have been reported in small solute transport and protein loss. * Objective: To assess permeability characteristics for a 1.4% glycerol dialysis solution compared to 1.36% glucose. * Design: Two standardized peritoneal permeability analyses (SPA), one using 1.4% glycerol and the other using 1.36% glucose, in random order, were performed within a span of 2 weeks in 10 stable CAPD patients. The length of the study dwell was 4 hours. Fluid kinetics and solute transport were calculated and signs of cell damage were compared for the two solutions. * Setting: Peritoneal dialysis unit in the Academic Medical Center, Amsterdam. * Results: Median values for the 1.4% glycerol SPA were as follows: net ultrafiltration 251 mt, which was higher than that for 1.36% glucose (12 mt, p < 0.01); transcapillary ultrafiltration rate 2.12 mt/min, which was higher than that for glucose (1.52 mL/min, p = 0.01); and effective lymphatic absorption rate 1.01 mt/min, which was not different from the glucose-based solution. Calculation of peritoneal reflection coefficients for glycerol and glucose showed lower values for glycerol compared to glucose (0.03 vs 0.04, calculated with both the convection and the diffusion models). A marked dip in dialysate-to-plasma ratio for sodium was seen in the 1.4% glycerol exchange, suggesting uncoupled water transport through water channels. Mass transfer area coefficients for urea, creatinine, and urate were similar for both solutions. Also, clearances of the macromolecules <beta>(2)-microglobulin, albumin, IgG, and alpha (2)-macroglobulin were not different for the two osmotic agents. The median absorption was higher for glycerol, 71% compared to 49% for glucose (p < 0.01), as could be expected from the lower molecular weight. The use of a 1.4% glycerol solution during a 4-hour dwell caused a small but significant median rise in plasma glycerol, from 0.22 mmol/L to 0.45 mmol/L (p = 0.02). Dialysate cancer antigen 125 and lactate dehydrogenase (LDH) concentrations during the dwell were not different for both solutions. * Conclusions: These findings show that glycerol is an effective osmotic agent that can replace glucose in short dwells and show no acute mesothelial damage. The higher net ultrafiltration obtained with 1.4% glycerol can be explained by the higher initial net osmotic pressure gradient. This was seen especially in the first hour of the dwell. Thereafter, the osmotic gradient diminished as a result of absorption. The dip in dialysate-to-plasma ratio for sodium seen in the glycerol dwell can also be explained by this high initial osmotic pressure gradient, implying that the effect of glycerol as an osmotic agent is more dependent on intact water channels than is glucose.
引用
收藏
页码:557 / 565
页数:9
相关论文
共 50 条
  • [1] Dialysate copeptin and peritoneal transport in incident peritoneal dialysis patients
    Fijalkowski, Maciej
    Safranow, Krzysztof
    Lindholm, Bengt
    Ciechanowski, Kazimierz
    Muraszko, Anna Maria
    Dolegowska, Barbara
    Dolegowska, Katarzyna
    Golembiewska, Edyta
    INTERNATIONAL UROLOGY AND NEPHROLOGY, 2019, 51 (09) : 1667 - 1673
  • [2] Dialysate copeptin and peritoneal transport in incident peritoneal dialysis patients
    Maciej Fijałkowski
    Krzysztof Safranow
    Bengt Lindholm
    Kazimierz Ciechanowski
    Anna Maria Muraszko
    Barbara Dołęgowska
    Katarzyna Dołęgowska
    Edyta Golembiewska
    International Urology and Nephrology, 2019, 51 : 1667 - 1673
  • [3] Peritoneal transport characteristics with glucose polymer based dialysate
    HoDacPannekeet, MM
    Schouten, N
    Langendijk, MJ
    Hiralall, JK
    deWaart, DR
    Struijk, DG
    Krediet, RT
    KIDNEY INTERNATIONAL, 1996, 50 (03) : 979 - 986
  • [4] PERITONEAL TRANSPORT CHARACTERISTICS, SODIUM SIEVING AND DIALYSATE ELECTROLYTE CLEARANCE IN PERITONEAL DIALYSIS PATIENTS: 4.25% PERITONEAL EQUILIBRATION TEST ANALYSIS
    Liao, Ruoxi
    Ma, Dengyan
    Zhou, Xueli
    Zhong, Hui
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2022, 37 : I499 - I501
  • [5] Bilious peritoneal dialysate in a peritoneal dialysis patient
    Fung, Winston Wing Shing
    Chow, Kai Ming
    Szeto, Cheuk Chun
    KIDNEY INTERNATIONAL, 2021, 100 (02) : 485 - 485
  • [6] GLYCEROL AS OSMOTIC AGENT IN PERITONEAL-DIALYSIS KINETICS OF PERITONEAL TRANSPORT
    LINDHOLM, B
    DANIELSSON, A
    GUNNARSSON, B
    TRANAEUS, A
    WERYNSKI, A
    DOLKART, RE
    BERGSTROM, J
    ARTIFICIAL ORGANS, 1984, 8 (01) : 117 - 117
  • [7] Effect of dialysis modality and membrane transport characteristics on dialysate protein losses of patients on peritoneal dialysis
    Kathuria, P
    Moore, HL
    Khanna, R
    Twardowski, ZJ
    Goel, S
    Nolph, KD
    PERITONEAL DIALYSIS INTERNATIONAL, 1997, 17 (05): : 449 - 454
  • [8] Dialysate leaks in peritoneal dialysis
    Leblanc, M
    Ouimet, D
    Pichette, V
    SEMINARS IN DIALYSIS, 2001, 14 (01) : 50 - 54
  • [9] Effects of alternative peritoneal dialysis solutions on peritoneal transport and cytokines/prostanoids dialysate concentrations
    Plum, J
    Fussholler, A
    Schonicke, G
    Busch, T
    Erren, C
    Fieseler, C
    Kirchgessner, J
    PasslickDeetjen, J
    Grabensee, B
    NIEREN-UND HOCHDRUCKKRANKHEITEN, 1997, 26 : S80 - S85
  • [10] Vaginal Leakage of Peritoneal Dialysate in a Peritoneal Dialysis Patient
    Kidir, Veysel
    Altuntas, Atila
    Inal, Salih
    Degirmenci, Bumin
    Sezer, Mehmet Tugrul
    THERAPEUTIC APHERESIS AND DIALYSIS, 2014, 18 (02) : 211 - 212