Accurate Fault Diagnosis in Transformers Using an Auxiliary Current-Compensation-Based Framework for Differential Relays

被引:13
|
作者
Ameli, Amir [1 ]
Ghafouri, Mohsen [2 ]
Zeineldin, Hatem H. [3 ]
Salama, Magdy M. A. [4 ]
El-Saadany, Ehab F. [5 ,6 ]
机构
[1] Lakehead Univ, Elect Engn Dept, Thunder Bay, ON P7B 5E1, Canada
[2] Concordia Inst Informat Syst Engn CIISE, Montreal, PQ H3G 1M8, Canada
[3] Cairo Univ, Fac Engn, Giza 12613, Egypt
[4] Univ Waterloo, Elect & Comp Engn Dept, Waterloo, ON N2L 3G1, Canada
[5] Khalifa Univ, Adv Power & Energy Ctr, Elect Engn & Comp Sci EECS Dept, Abu Dhabi, U Arab Emirates
[6] Univ Waterloo, Elect & Comp Engn ECE Dept, Waterloo, ON N2L 3G1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Cross-country faults; current transformer (CT) saturation; differential protection; inrush current; internal faults; linear parameter varying (LPV) systems; over-excitation; state-space model; INRUSH CURRENTS; INTERNAL FAULTS; WAVE-FORM; PROTECTION; CT; DISCRIMINATION;
D O I
10.1109/TIM.2021.3097855
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article proposes an auxiliary framework to address the challenges of transformer differential protection for single-phase transformers or three-phase transformer banks. This framework enables the differential scheme to: 1) work properly if transformers or current transformers (CTs) saturate; 2) detect internal and cross-country faults; 3) detect internal faults while energizing transformers; and 4) detect inrush currents. Unlike the existing methods in the literature, this framework addresses the above-mentioned challenges without sacrificing the sensitivity and/or the speed of differential relays. The proposed method models a transformer and its CTs with linear parameter varying (LPV) state-space equations, and uses the polytopic form of these equations and LPV observers to estimate the states of the transformer and its CTs. To address the CT saturation problem, it accurately estimates primary currents of CTs using their secondary currents. Thus, the differential scheme uses the estimated primary currents of its CTs instead of their distorted secondary currents. Additionally, the proposed framework detects inrush currents of transformers and differentiates them from internal faults by estimating the primary current of the transformer and comparing the estimated and measured primary currents. A discrepancy between the measured and estimated primary currents signifies an internal fault. The results of electromagnetic transient simulations in Electromagnetic Transient Program (EMTP) platform corroborate the effectiveness of the proposed method.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Accurate Impedance Based Fault Location Algorithm Using Communication between Protective Relays
    Dzienis, Cezary
    Yelgin, Yilmaz
    Washer, Marie
    Maun, Jean-Claude
    2015 MODERN ELECTRIC POWER SYSTEMS (MEPS), 2015,
  • [2] Phase-compensation-based dynamic time warping for fault diagnosis using the motor current signal
    Zhen, D.
    Zhao, H. L.
    Gu, F.
    Ball, A. D.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2012, 23 (05)
  • [3] Differential evolution optimization based ensemble framework for accurate cervical cancer diagnosis
    Bilal, Omair
    Asif, Sohaib
    Zhao, Ming
    Li, Yangfan
    Tang, Fengxiao
    Zhu, Yusen
    Applied Soft Computing, 2024, 167
  • [4] A Learning-Based Framework for Detecting Cyber-Attacks Against Line Current Differential Relays
    Ameli, Amir
    Ayad, Abdelrahman
    El-Saadany, Ehab F.
    Salama, Magdy
    Youssef, Amr
    IEEE TRANSACTIONS ON POWER DELIVERY, 2021, 36 (04) : 2274 - 2286
  • [5] Measurement of Fault-Loop Impedance in Three-Terminal Line Using Signals of Current Differential Relays
    Rosolowski, Eugeniusz
    Izykowski, Jan
    Pierz, Piotr
    2016 2ND INTERNATIONAL CONFERENCE ON INTELLIGENT ENERGY AND POWER SYSTEMS (IEPS), 2016,
  • [6] Structural Rotor Fault Diagnosis Using Attention-Based Sensor Fusion and Transformers
    Nath, Aneesh G.
    Udmale, Sandeep S.
    Raghuwanshi, Divyanshu
    Singh, Sanjay Kumar
    IEEE SENSORS JOURNAL, 2022, 22 (01) : 707 - 719
  • [7] High Impedance Restricted Earth Fault Relay Settings: Impact of using Auxiliary Current Transformers at Neutral End for Ratio Matching
    Payyalore S.V.
    Palanisamy S.
    Journal of The Institution of Engineers (India): Series B, 2022, 103 (02) : 469 - 475
  • [8] High Impedance Restricted Earth Fault Relay Settings: Impact of using Auxiliary Current Transformers at Neutral End for Ratio Matching
    Subramanian Vanchier Payyalore
    Sridhar Palanisamy
    Journal of The Institution of Engineers (India): Series B, 2022, 103 : 469 - 475
  • [9] Overcurrent Relays Coordination in Interconnected Networks Using Accurate Analytical Method and Based on Determination of Fault Critical Point
    Alkaran, Davood Solati
    Vatani, Mohammad Reza
    Sanjari, Mohammad Javad
    Gharehpetian, Gevork B.
    Yatim, Abdul Halim
    IEEE TRANSACTIONS ON POWER DELIVERY, 2015, 30 (02) : 870 - 877
  • [10] Fault dictionary based switched current circuit fault diagnosis using entropy as a preprocessor
    Long, Ying
    He, Yigang
    Yuan, Lifen
    ANALOG INTEGRATED CIRCUITS AND SIGNAL PROCESSING, 2011, 66 (01) : 93 - 102