Voltage Sag Mitigation Using Direct Converter Based DVR without Error Signal

被引:4
|
作者
Rahman, S. Abdul [1 ]
Mitiku, Estifanos Dagnew [1 ]
Mule, Shumye Birhan [1 ]
Aduye, Gebrie Teshome [1 ]
Huluka, Mekete Asmare [1 ]
Mesfin, Solomon [1 ]
机构
[1] Univ Gondar, Inst Technol, Gondar, Ethiopia
来源
PRZEGLAD ELEKTROTECHNICZNY | 2021年 / 97卷 / 12期
关键词
Dynamic Voltage Restorer; Voltage Sag; Direct Converter; Series Transformer; Mat lab Simulink; Without Error Signal; RESTORER;
D O I
10.15199/48.2021.12.05
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Dynamic voltage restorer is considered to be one of the best device to compensate voltage sag and swell. Recently the DVRs based on direct converters are very popular and works are getting published for various topologies and modulating techniques to explore the efficiency and worth of the same. In this paper, the direct converter is realized using only two bidirectional switches, in order to mitigate voltage sag. The voltage required to compensate the voltage sag is taken from the same phase where the voltage sag has occurred. The direct converter is connected between the line in which the voltage sag has occurred and the series transformer. In the conventional PWM generation technique, the supply voltage is measured and compared with the reference voltage in order to find out the voltage sag and the error voltage signal. This error signal will be compared with the carrier to generate the PWM pulses. Though already papers have been published to mitigate voltage sag using direct converter, in this paper, as one of the efforts to show the flexibility of the direct converter based DVR, the voltage sag is mitigated without measuring the supply voltage and without generating the error signals, since the power required to mitigate the sag is taken from the phase where it occurred. Ordinary PWM technique is used to control the bidirectional switches. In this proposed methodology the DVR is able to compensate 22% of voltage sag. The simulation is carried out in Matlab Simulink and the results are presented for verification.
引用
收藏
页码:34 / 37
页数:4
相关论文
共 50 条
  • [1] Analysis the operation of DVR in voltage sag mitigation using EMTP
    Monsef, H
    Tamimi, B
    Proceedings of the 4th WSEAS International Conference on Applications of Electrical Engineering, 2005, : 132 - 138
  • [2] Small-Signal Modeling of a Single-Phase DVR for Voltage Sag Mitigation
    Meloni, Lucas F. J.
    Rezek, Angelo J. J.
    Ribeiro, Enio R.
    PROCEEDINGS OF 2016 17TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER (ICHQP), 2016, : 55 - 59
  • [3] Voltage sag mitigation using a high-frequency-link cycloconverter-based DVR
    Sree, H
    Mohan, N
    IECON 2000: 26TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-4: 21ST CENTURY TECHNOLOGIES AND INDUSTRIAL OPPORTUNITIES, 2000, : 344 - 349
  • [4] Mitigation of Voltage Sag/Swell and Harmonics using Self-Supported DVR
    Kumar, Amit
    Pal, Nidhi Singh
    Ansari, M. A.
    PROCEEDINGS OF THE FIRST IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, INTELLIGENT CONTROL AND ENERGY SYSTEMS (ICPEICES 2016), 2016,
  • [5] An Improved Direct AC-AC Converter for Voltage Sag Mitigation
    Jothibasu, Suma
    Mishra, Mahesh K.
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (01) : 21 - 29
  • [6] Mitigation Voltage Sag/Swell and Harmonics Using DVR Supplied by BES and PV System
    Kiswantono, Agus
    Prasetyo, Eko
    Amirullah
    2018 ELECTRICAL POWER, ELECTRONICS, COMMUNICATIONS, CONTROLS, AND INFORMATICS SEMINAR (EECCIS), 2018, : 36 - 41
  • [7] High-frequency-link cycloconverter-based DVR for voltage sag mitigation
    Sree, H
    Mohan, N
    CONFERENCE RECORD OF THE 2000 TWENTY-FOURTH INTERNATIONAL POWER MODULATOR SYMPOSIUM, 50TH ANNIVERSARY, 2000, : 97 - 100
  • [8] Improvement of Dynamic Voltage Restorer (DVR) Using Proportional Integral (PI) Controller for Mitigation of Voltage Sag
    Hamza, A. H. A.
    El-Koliel, M. S.
    Ali, M. N.
    El-Eissawi, H.
    Hafez, M. M.
    ARAB JOURNAL OF NUCLEAR SCIENCES AND APPLICATIONS, 2015, 48 (01): : 44 - 52
  • [9] The Voltage Sag Mitigation Method Based on Hybrid SMES-BES Dynamic Voltage Restorer(DVR)
    Ding, Kai
    Li, Wei
    Hu, Pan
    Hu, Anping
    Tao, Yibin
    Zhuang, Jun
    Lu, Hong
    PROCEEDINGS OF 2019 IEEE 3RD INTERNATIONAL ELECTRICAL AND ENERGY CONFERENCE (CIEEC), 2019, : 545 - 549
  • [10] A Simplified Algorithm for Sag and Harmonic Mitigation using DVR
    Tasre, Mohan B.
    Dhole, Gajanan M.
    Jadhao, Saurabh S.
    Sharma, Rajesh B.
    2017 INTERNATIONAL CONFERENCE ON COMPUTING, COMMUNICATION, CONTROL AND AUTOMATION (ICCUBEA), 2017,