A deep learning-based whole-body solution for PET/MRI attenuation correction

被引:8
|
作者
Ahangari, Sahar [1 ,2 ]
Olin, Anders Beck [1 ,2 ]
Federspiel, Marianne Kinggard [1 ,2 ]
Jakoby, Bjoern [3 ]
Andersen, Thomas Lund [1 ,2 ]
Hansen, Adam Espe [1 ,2 ,4 ,5 ]
Fischer, Barbara Malene [1 ,2 ,4 ]
Andersen, Flemming Littrup [1 ,2 ,4 ]
机构
[1] Rigshosp, Dept Clin Physiol, Nucl Med, Copenhagen, Denmark
[2] Rigshosp, PET, Copenhagen, Denmark
[3] Siemens Healthcare GmbH, Erlangen, Germany
[4] Univ Copenhagen, Dept Clin Med, Copenhagen, Denmark
[5] Rigshosp, Dept Diagnost Radiol, Copenhagen, Denmark
基金
欧盟地平线“2020”;
关键词
PET; MRI; MR-AC; Attenuation correction; Deep learning; Whole body; QUANTITATIVE-EVALUATION; MRI; TRUNCATION;
D O I
10.1186/s40658-022-00486-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Deep convolutional neural networks have demonstrated robust and reliable PET attenuation correction (AC) as an alternative to conventional AC methods in integrated PET/MRI systems. However, its whole-body implementation is still challenging due to anatomical variations and the limited MRI field of view. The aim of this study is to investigate a deep learning (DL) method to generate voxel-based synthetic CT (sCT) from Dixon MRI and use it as a whole-body solution for PET AC in a PET/MRI system. Materials and methods Fifteen patients underwent PET/CT followed by PET/MRI with whole-body coverage from skull to feet. We performed MRI truncation correction and employed co-registered MRI and CT images for training and leave-one-out cross-validation. The network was pretrained with region-specific images. The accuracy of the AC maps and reconstructed PET images were assessed by performing a voxel-wise analysis and calculating the quantification error in SUV obtained using DL-based sCT (PETsCT) and a vendor-provided atlas-based method (PETAtlas), with the CT-based reconstruction (PETCT) serving as the reference. In addition, region-specific analysis was performed to compare the performances of the methods in brain, lung, liver, spine, pelvic bone, and aorta. Results Our DL-based method resulted in better estimates of AC maps with a mean absolute error of 62 HU, compared to 109 HU for the atlas-based method. We found an excellent voxel-by-voxel correlation between PETCT and PETsCT (R-2 = 0.98). The absolute percentage difference in PET quantification for the entire image was 6.1% for PETsCT and 11.2% for PETAtlas. The regional analysis showed that the average errors and the variability for PETsCT were lower than PETAtlas in all regions. The largest errors were observed in the lung, while the smallest biases were observed in the brain and liver. Conclusions Experimental results demonstrated that a DL approach for whole-body PET AC in PET/MRI is feasible and allows for more accurate results compared with conventional methods. Further evaluation using a larger training cohort is required for more accurate and robust performance.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Whole-body MR-based attenuation correction for PET using UTE Sequences
    Keereman, V.
    Fierens, Y.
    De Deene, Y.
    Vandenberghe, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S220 - S220
  • [32] Fuzzy clustering-based segmented attenuation correction in whole-body PET imaging
    Zaidi, H
    Diaz-Gomez, M
    Boudraa, A
    Slosman, DO
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (07): : 1143 - 1160
  • [33] CT-based attenuation correction of whole-body radiotherapy treatment positioning devices in PET/MRI hybrid imaging
    Taeubert, Leticia
    Berker, Yannick
    Beuthien-Baumann, Bettina
    Hoffmann, Aswin L.
    Troost, Esther G. C.
    Kachelriess, Marc
    Gillmann, Clarissa
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (23):
  • [34] Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging
    David Izquierdo-Garcia
    Stephen J. Sawiak
    Karin Knesaurek
    Jagat Narula
    Valentin Fuster
    Joseph Machac
    Zahi A. Fayad
    European Journal of Nuclear Medicine and Molecular Imaging, 2014, 41 : 1574 - 1584
  • [35] Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging
    Izquierdo-Garcia, David
    Sawiak, Stephen J.
    Knesaurek, Karin
    Narula, Jagat
    Fuster, Valentin
    Machac, Joseph
    Fayad, Zahi A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 (08) : 1574 - 1584
  • [36] STUDY ON THE USE OF TRANSMISSION SCANS FOR WHOLE-BODY PET ATTENUATION CORRECTION
    CHATZIIOANNOU, A
    DAHLBOM, M
    HOH, CJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) : 1545 - 1550
  • [37] Accelerating Whole-Body Diffusion-weighted MRI with Deep Learning-based Denoising Image Filters
    Zormpas-Petridis, Konstantinos
    Tunariu, Nina
    Curcean, Andra
    Messiou, Christina
    Curcean, Sebastian
    Collins, David J.
    Hughes, Julie C.
    Jamin, Yann
    Koh, Dow-Mu
    Blackledge, Matthew D.
    RADIOLOGY-ARTIFICIAL INTELLIGENCE, 2021, 3 (05)
  • [38] SIMULTANEOUS EMISSION AND TRANSMISSION MEASUREMENTS FOR ATTENUATION CORRECTION IN WHOLE-BODY PET
    MEIKLE, SR
    BAILEY, DL
    HOOPER, PK
    EBERL, S
    HUTTON, BF
    JONES, WF
    JOURNAL OF NUCLEAR MEDICINE, 1995, 36 (09) : 1680 - 1688
  • [39] Deep learninga(sic)'based CT-free attenuation and scatter correction for pediatric whole-body PET imaging
    Han, Chenyang
    Trout, Andrew
    MacLean, Joseph
    Zhu, Jieyuhan
    Tang, Jing
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [40] Assessment of deep learning-based PET attenuation correction frameworks in the sinogram domain
    Arabi, Hossein
    Zaidi, Habib
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (14):